array:25 [
  "pii" => "S0211699515001459"
  "issn" => "02116995"
  "doi" => "10.1016/j.nefro.2015.04.007"
  "estado" => "S300"
  "fechaPublicacion" => "2015-11-01"
  "aid" => "93"
  "copyright" => "Sociedad Española de Nefrología"
  "copyrightAnyo" => "2015"
  "documento" => "article"
  "crossmark" => 0
  "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
  "subdocumento" => "fla"
  "cita" => "Nefrologia. 2015;35:533-8"
  "abierto" => array:3 [
    "ES" => true
    "ES2" => true
    "LATM" => true
  ]
  "gratuito" => true
  "lecturas" => array:2 [
    "total" => 9173
    "formatos" => array:3 [
      "EPUB" => 315
      "HTML" => 7533
      "PDF" => 1325
    ]
  ]
  "Traduccion" => array:1 [
    "en" => array:20 [
      "pii" => "S201325141500125X"
      "issn" => "20132514"
      "doi" => "10.1016/j.nefroe.2015.04.005"
      "estado" => "S300"
      "fechaPublicacion" => "2015-11-01"
      "aid" => "93"
      "copyright" => "Sociedad Española de Nefrología"
      "documento" => "article"
      "crossmark" => 0
      "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
      "subdocumento" => "fla"
      "cita" => "Nefrologia (English Version). 2015;35:533-8"
      "abierto" => array:3 [
        "ES" => true
        "ES2" => true
        "LATM" => true
      ]
      "gratuito" => true
      "lecturas" => array:2 [
        "total" => 5110
        "formatos" => array:3 [
          "EPUB" => 281
          "HTML" => 4003
          "PDF" => 826
        ]
      ]
      "en" => array:12 [
        "idiomaDefecto" => true
        "cabecera" => "<span class="elsevierStyleTextfn">Original article</span>"
        "titulo" => "What is the optimum dialysate flow in post-dilution online haemodiafiltration&#63;"
        "tienePdf" => "en"
        "tieneTextoCompleto" => "en"
        "tieneResumen" => array:2 [
          0 => "en"
          1 => "es"
        ]
        "paginas" => array:1 [
          0 => array:2 [
            "paginaInicial" => "533"
            "paginaFinal" => "538"
          ]
        ]
        "titulosAlternativos" => array:1 [
          "es" => array:1 [
            "titulo" => "&#191;Cu&#225;l es el flujo de ba&#241;o &#243;ptimo en la hemodiafiltraci&#243;n <span class="elsevierStyleItalic">on-line</span> posdilucional&#63;"
          ]
        ]
        "contieneResumen" => array:2 [
          "en" => true
          "es" => true
        ]
        "contieneTextoCompleto" => array:1 [
          "en" => true
        ]
        "contienePdf" => array:1 [
          "en" => true
        ]
        "autores" => array:1 [
          0 => array:2 [
            "autoresLista" => "Marta Albalate Ram&#243;n, Patricia de Sequera Ortiz, Rafael P&#233;rez-Garc&#237;a, Elena Corchete Prats, Roberto Alc&#225;zar Arroyo, Mayra Ortega D&#237;az, Marta Puerta Carretero"
            "autores" => array:7 [
              0 => array:2 [
                "nombre" => "Marta"
                "apellidos" => "Albalate Ram&#243;n"
              ]
              1 => array:2 [
                "nombre" => "Patricia"
                "apellidos" => "de Sequera Ortiz"
              ]
              2 => array:2 [
                "nombre" => "Rafael"
                "apellidos" => "P&#233;rez-Garc&#237;a"
              ]
              3 => array:2 [
                "nombre" => "Elena"
                "apellidos" => "Corchete Prats"
              ]
              4 => array:2 [
                "nombre" => "Roberto"
                "apellidos" => "Alc&#225;zar Arroyo"
              ]
              5 => array:2 [
                "nombre" => "Mayra"
                "apellidos" => "Ortega D&#237;az"
              ]
              6 => array:2 [
                "nombre" => "Marta"
                "apellidos" => "Puerta Carretero"
              ]
            ]
          ]
        ]
      ]
      "idiomaDefecto" => "en"
      "Traduccion" => array:1 [
        "es" => array:9 [
          "pii" => "S0211699515001459"
          "doi" => "10.1016/j.nefro.2015.04.007"
          "estado" => "S300"
          "subdocumento" => ""
          "abierto" => array:3 [
            "ES" => true
            "ES2" => true
            "LATM" => true
          ]
          "gratuito" => true
          "lecturas" => array:1 [
            "total" => 0
          ]
          "idiomaDefecto" => "es"
          "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0211699515001459?idApp=UINPBA000064"
        ]
      ]
      "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S201325141500125X?idApp=UINPBA000064"
      "url" => "/20132514/0000003500000006/v2_201703220324/S201325141500125X/v2_201703220324/en/main.assets"
    ]
  ]
  "itemSiguiente" => array:20 [
    "pii" => "S0211699515001423"
    "issn" => "02116995"
    "doi" => "10.1016/j.nefro.2015.09.004"
    "estado" => "S300"
    "fechaPublicacion" => "2015-11-01"
    "aid" => "90"
    "copyright" => "Sociedad Espa&#241;ola de Nefrolog&#237;a"
    "documento" => "article"
    "crossmark" => 0
    "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
    "subdocumento" => "fla"
    "cita" => "Nefrologia. 2015;35:539-46"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 9491
      "formatos" => array:3 [
        "EPUB" => 341
        "HTML" => 8388
        "PDF" => 762
      ]
    ]
    "es" => array:13 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Original</span>"
      "titulo" => "Desarrollo de la gesti&#243;n medioambiental certificada en unidades hospitalarias y ambulatorias de hemodi&#225;lisis"
      "tienePdf" => "es"
      "tieneTextoCompleto" => "es"
      "tieneResumen" => array:2 [
        0 => "es"
        1 => "en"
      ]
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "539"
          "paginaFinal" => "546"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "en" => array:1 [
          "titulo" => "Development of certified environmental management in hospital and outpatient haemodialysis units"
        ]
      ]
      "contieneResumen" => array:2 [
        "es" => true
        "en" => true
      ]
      "contieneTextoCompleto" => array:1 [
        "es" => true
      ]
      "contienePdf" => array:1 [
        "es" => true
      ]
      "resumenGrafico" => array:2 [
        "original" => 0
        "multimedia" => array:7 [
          "identificador" => "fig0005"
          "etiqueta" => "Figura 1"
          "tipo" => "MULTIMEDIAFIGURA"
          "mostrarFloat" => true
          "mostrarDisplay" => false
          "figura" => array:1 [
            0 => array:4 [
              "imagen" => "gr1.jpeg"
              "Alto" => 4333
              "Ancho" => 2717
              "Tamanyo" => 1024824
            ]
          ]
          "descripcion" => array:1 [
            "es" => "<p id="spar0055" class="elsevierStyleSimplePara elsevierViewall">Alcance de los SGMA en hospitales con hemodi&#225;lisis del SNS&#46;</p> <p id="spar0060" class="elsevierStyleSimplePara elsevierViewall">Listado de hospitales por comunidad aut&#243;noma con hemodi&#225;lisis y SGMA certificado&#58; ISO&#160;14001 y EMAS&#46; Se destacan aquellos con ambos&#46;</p>"
          ]
        ]
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "Sergio Garc&#237;a Vicente, Mar&#237;a Morales Su&#225;rez-Varela, Anna Mart&#237; Monr&#243;s, Agust&#237;n Llopis Gonz&#225;lez"
          "autores" => array:4 [
            0 => array:2 [
              "nombre" => "Sergio"
              "apellidos" => "Garc&#237;a Vicente"
            ]
            1 => array:2 [
              "nombre" => "Mar&#237;a"
              "apellidos" => "Morales Su&#225;rez-Varela"
            ]
            2 => array:2 [
              "nombre" => "Anna"
              "apellidos" => "Mart&#237; Monr&#243;s"
            ]
            3 => array:2 [
              "nombre" => "Agust&#237;n"
              "apellidos" => "Llopis Gonz&#225;lez"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "es"
    "Traduccion" => array:1 [
      "en" => array:9 [
        "pii" => "S2013251415001212"
        "doi" => "10.1016/j.nefroe.2015.12.001"
        "estado" => "S300"
        "subdocumento" => ""
        "abierto" => array:3 [
          "ES" => true
          "ES2" => true
          "LATM" => true
        ]
        "gratuito" => true
        "lecturas" => array:1 [
          "total" => 0
        ]
        "idiomaDefecto" => "en"
        "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2013251415001212?idApp=UINPBA000064"
      ]
    ]
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0211699515001423?idApp=UINPBA000064"
    "url" => "/02116995/0000003500000006/v1_201512190045/S0211699515001423/v1_201512190045/es/main.assets"
  ]
  "itemAnterior" => array:20 [
    "pii" => "S0211699515001460"
    "issn" => "02116995"
    "doi" => "10.1016/j.nefro.2015.09.007"
    "estado" => "S300"
    "fechaPublicacion" => "2015-11-01"
    "aid" => "94"
    "copyright" => "Sociedad Espa&#241;ola de Nefrolog&#237;a"
    "documento" => "article"
    "crossmark" => 0
    "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
    "subdocumento" => "fla"
    "cita" => "Nefrologia. 2015;35:523-32"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 30890
      "formatos" => array:3 [
        "EPUB" => 310
        "HTML" => 27806
        "PDF" => 2774
      ]
    ]
    "es" => array:13 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Original</span>"
      "titulo" => "Insuficiencia renal aguda relacionada con medicamentos en pacientes hospitalizados"
      "tienePdf" => "es"
      "tieneTextoCompleto" => "es"
      "tieneResumen" => array:2 [
        0 => "es"
        1 => "en"
      ]
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "523"
          "paginaFinal" => "532"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "en" => array:1 [
          "titulo" => "Drug-related acute renal failure in hospitalised patients"
        ]
      ]
      "contieneResumen" => array:2 [
        "es" => true
        "en" => true
      ]
      "contieneTextoCompleto" => array:1 [
        "es" => true
      ]
      "contienePdf" => array:1 [
        "es" => true
      ]
      "resumenGrafico" => array:2 [
        "original" => 0
        "multimedia" => array:7 [
          "identificador" => "fig0005"
          "etiqueta" => "Figura 1"
          "tipo" => "MULTIMEDIAFIGURA"
          "mostrarFloat" => true
          "mostrarDisplay" => false
          "figura" => array:1 [
            0 => array:4 [
              "imagen" => "gr1.jpeg"
              "Alto" => 2591
              "Ancho" => 2503
              "Tamanyo" => 297996
            ]
          ]
          "descripcion" => array:1 [
            "es" => "<p id="spar0055" class="elsevierStyleSimplePara elsevierViewall">Diagrama de flujo de los ingresos con insuficiencia renal aguda durante la hospitalizaci&#243;n&#46;</p>"
          ]
        ]
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "Lujan Iavecchia, Gloria Cereza Garc&#237;a, M&#242;nica Sabat&#233; Gallego, Xavier Vidal Guitart, Natalia Ramos Terrades, Judith de la Torre, Alfons Segarra Medrano, Ant&#242;nia Agust&#237; Escasany"
          "autores" => array:8 [
            0 => array:2 [
              "nombre" => "Lujan"
              "apellidos" => "Iavecchia"
            ]
            1 => array:2 [
              "nombre" => "Gloria"
              "apellidos" => "Cereza Garc&#237;a"
            ]
            2 => array:2 [
              "nombre" => "M&#242;nica"
              "apellidos" => "Sabat&#233; Gallego"
            ]
            3 => array:2 [
              "nombre" => "Xavier"
              "apellidos" => "Vidal Guitart"
            ]
            4 => array:2 [
              "nombre" => "Natalia"
              "apellidos" => "Ramos Terrades"
            ]
            5 => array:2 [
              "nombre" => "Judith"
              "apellidos" => "de la Torre"
            ]
            6 => array:2 [
              "nombre" => "Alfons"
              "apellidos" => "Segarra Medrano"
            ]
            7 => array:2 [
              "nombre" => "Ant&#242;nia"
              "apellidos" => "Agust&#237; Escasany"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "es"
    "Traduccion" => array:1 [
      "en" => array:9 [
        "pii" => "S201325141600002X"
        "doi" => "10.1016/j.nefroe.2016.01.001"
        "estado" => "S300"
        "subdocumento" => ""
        "abierto" => array:3 [
          "ES" => true
          "ES2" => true
          "LATM" => true
        ]
        "gratuito" => true
        "lecturas" => array:1 [
          "total" => 0
        ]
        "idiomaDefecto" => "en"
        "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S201325141600002X?idApp=UINPBA000064"
      ]
    ]
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0211699515001460?idApp=UINPBA000064"
    "url" => "/02116995/0000003500000006/v1_201512190045/S0211699515001460/v1_201512190045/es/main.assets"
  ]
  "es" => array:19 [
    "idiomaDefecto" => true
    "cabecera" => "<span class="elsevierStyleTextfn">Original</span>"
    "titulo" => "&#191;Cu&#225;l es el flujo de ba&#241;o &#243;ptimo en la hemodiafiltraci&#243;n <span class="elsevierStyleItalic">on-line</span> posdilucional&#63;"
    "tieneTextoCompleto" => true
    "paginas" => array:1 [
      0 => array:2 [
        "paginaInicial" => "533"
        "paginaFinal" => "538"
      ]
    ]
    "autores" => array:1 [
      0 => array:4 [
        "autoresLista" => "Marta Albalate Ram&#243;n, Patricia de Sequera Ortiz, Rafael P&#233;rez-Garc&#237;a, Elena Corchete Prats, Roberto Alc&#225;zar Arroyo, Mayra Ortega D&#237;az, Marta Puerta Carretero"
        "autores" => array:7 [
          0 => array:4 [
            "nombre" => "Marta"
            "apellidos" => "Albalate Ram&#243;n"
            "email" => array:1 [
              0 => "malbalater&#64;senefro&#46;org"
            ]
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">&#42;</span>"
                "identificador" => "cor0005"
              ]
            ]
          ]
          1 => array:2 [
            "nombre" => "Patricia"
            "apellidos" => "de Sequera Ortiz"
          ]
          2 => array:2 [
            "nombre" => "Rafael"
            "apellidos" => "P&#233;rez-Garc&#237;a"
          ]
          3 => array:2 [
            "nombre" => "Elena"
            "apellidos" => "Corchete Prats"
          ]
          4 => array:2 [
            "nombre" => "Roberto"
            "apellidos" => "Alc&#225;zar Arroyo"
          ]
          5 => array:2 [
            "nombre" => "Mayra"
            "apellidos" => "Ortega D&#237;az"
          ]
          6 => array:2 [
            "nombre" => "Marta"
            "apellidos" => "Puerta Carretero"
          ]
        ]
        "afiliaciones" => array:1 [
          0 => array:2 [
            "entidad" => "Servicio de Nefrolog&#237;a&#44; Hospital Infanta Leonor&#44; Madrid&#44; Espa&#241;a"
            "identificador" => "aff0005"
          ]
        ]
        "correspondencia" => array:1 [
          0 => array:3 [
            "identificador" => "cor0005"
            "etiqueta" => "&#8270;"
            "correspondencia" => "Autor para correspondencia&#46;"
          ]
        ]
      ]
    ]
    "titulosAlternativos" => array:1 [
      "en" => array:1 [
        "titulo" => "What is the optimum dialysate flow in post-dilution online haemodiafiltration&#63;"
      ]
    ]
    "textoCompleto" => "<span class="elsevierStyleSections"><p id="par0005" class="elsevierStylePara elsevierViewall">La hemodiafiltraci&#243;n en l&#237;nea posdilucional &#40;HDFOL&#41; es una t&#233;cnica de tratamiento sustitutivo que tiene diversas ventajas respecto a la hemodi&#225;lisis &#40;HD&#41;&#58; mejor&#237;a de la estabilidad hemodin&#225;mica&#44; de la respuesta a los agentes estimulantes de la eritropoyesis y a la hormona del crecimiento en ni&#241;os en di&#225;lisis&#44; mayor eliminaci&#243;n de fosfatos y &#946;2-microglobulina&#44; disminuci&#243;n de la incidencia de la amiloidosis relacionada con la di&#225;lisis y de los marcadores-mediadores de inflamaci&#243;n cr&#243;nica&#44; mejor preservaci&#243;n del estado nutricional y de la funci&#243;n renal residual &#40;FRR&#41;&#44; respuesta favorable de la encefalopat&#237;a hep&#225;tica y&#44; en estudios recientes&#44; mejor supervivencia<a class="elsevierStyleCrossRef" href="#bib0130"><span class="elsevierStyleSup">1</span></a>&#46; En ella se usa el propio l&#237;quido de di&#225;lisis &#40;LD&#41; &#40;ultrapuro&#41; como l&#237;quido de reposici&#243;n y&#44; aunque se considera que es coste-efectiva<a class="elsevierStyleCrossRef" href="#bib0135"><span class="elsevierStyleSup">2</span></a>&#44; su uso en ocasiones se ha limitado por la necesidad de utilizar grandes vol&#250;menes de LD&#46;</p><p id="par0010" class="elsevierStylePara elsevierViewall">En HD para controlar la dosis de di&#225;lisis administrada se utilizan el Kt&#47;V o el Kt basados en unos niveles m&#237;nimos por debajo de los cuales aumenta la mortalidad&#46; Las gu&#237;as cl&#237;nicas recomiendan un Kt&#47;V m&#237;nimo de 1&#44;2 o un ratio de reducci&#243;n de urea del 65&#37;&#44; pero los diferentes monitores de HD han incorporado biosensores que miden de forma no invasiva la dialisancia i&#243;nica efectiva que es equivalente al aclaramiento de urea &#40;K&#41;&#46; Estos sensores permiten calcular la dosis de di&#225;lisis sin carga de trabajo&#44; sin determinaciones anal&#237;ticas ni coste adicional&#44; evitando los sesgos que conlleva la inclusi&#243;n del t&#233;rmino V &#40;volumen de distribuci&#243;n de urea&#41; y dando una medida real de la dosis de di&#225;lisis recibida en cada sesi&#243;n&#46; En 1999&#44; Lowrie et al&#46; propusieron el Kt como marcador de dosis de di&#225;lisis y mortalidad&#44; recomendando un Kt m&#237;nimo de 40-45&#160;L para las mujeres y 45-50 para los hombres<a class="elsevierStyleCrossRef" href="#bib0140"><span class="elsevierStyleSup">3</span></a>&#46; En un estudio de 3&#46;009 pacientes&#44; observaron que un mayor Kt se acompa&#241;aba de una mayor supervivencia e individualizaron la prescripci&#243;n del Kt ajust&#225;ndola al &#225;rea de superficie corporal &#40;SC&#41;&#44; en una medida tremendamente exigente<a class="elsevierStyleCrossRef" href="#bib0145"><span class="elsevierStyleSup">4</span></a>&#46; Aunque est&#225; por aclarar si las dosis de di&#225;lisis son las mismas en HDFOL&#44; mientras no contemos con otras evidencias&#44; los pacientes en HDFOL deber&#237;an tener los mismos objetivos que los de HD&#46; Adem&#225;s&#44; distintos estudios han mostrado que la cantidad de volumen convectivo administrado parece ser decisivo en la mejora de supervivencia&#44; que fue de 15 l&#47;sesi&#243;n en el European Dialysis Outcomes and Practice Pattern Study &#40;DOPPS&#41;<a class="elsevierStyleCrossRef" href="#bib0150"><span class="elsevierStyleSup">5</span></a>&#44; 17&#44;4 l&#47;sesi&#243;n en el estudio turco<a class="elsevierStyleCrossRef" href="#bib0155"><span class="elsevierStyleSup">6</span></a>&#44; 21&#44;9&#160;L en el Convective Transport Study &#40;CONTRAST&#41;<a class="elsevierStyleCrossRef" href="#bib0160"><span class="elsevierStyleSup">7</span></a> y de 23&#44;1 L en el Estudio de Supervivencia de Hemodiafiltraci&#243;n On-Line &#40;ESHOL&#41;<a class="elsevierStyleCrossRef" href="#bib0165"><span class="elsevierStyleSup">8</span></a>&#46; Estos estudios ponen en evidencia la necesidad de alcanzar vol&#250;menes convectivos altos para reducir la mortalidad y&#44; por ello&#44; nosotros&#44; siguiendo los est&#225;ndares de calidad m&#225;s exigentes&#44; nos marcamos como objetivo conseguir vol&#250;menes superiores a 24 L&#46;</p><p id="par0015" class="elsevierStylePara elsevierViewall">La dosis de di&#225;lisis &#40;o Kt&#41; depende del KoA del dializador&#44; de las condiciones de flujo &#40;sangre &#91;Qb&#93;&#44; l&#237;quido de di&#225;lisis &#91;Qd&#93; y ultrafiltraci&#243;n&#41; y del tiempo de di&#225;lisis&#46; Estudios realizados en los a&#241;os 90 encontraron que el KoA y el aclaramiento podr&#237;an aumentar al incrementar el Qd<a class="elsevierStyleCrossRefs" href="#bib0170"><span class="elsevierStyleSup">9&#44;10</span></a>&#46; Los resultados de estos estudios en HD llevaron a aumentar el Qd a 700-800<span class="elsevierStyleHsp" style=""></span>ml&#47;min para mejorar el aclaramiento&#46; Pero en los &#250;ltimos a&#241;os los cambios en el dise&#241;o de los dializadores &#40;fibras cruzadas con un cierto &#225;ngulo u onduladas&#44; con diferente densidad de empaquetado y distribuidores del flujo en la entrada del ba&#241;o&#41; han mejorado sus prestaciones<a class="elsevierStyleCrossRefs" href="#bib0180"><span class="elsevierStyleSup">11&#8211;13</span></a>&#46; De este modo&#44; trabajos m&#225;s recientes han mostrado que con estos dializadores&#44; aumentar el Qd no modifica pr&#225;cticamente la eficacia de la HD<a class="elsevierStyleCrossRefs" href="#bib0195"><span class="elsevierStyleSup">14&#8211;18</span></a>&#46; Pero&#44; &#191;qu&#233; ocurre en HDFOL&#63; Nosotros no hemos encontrado ning&#250;n trabajo que estudie el efecto que tiene utilizar distintos Qd&#44; ni que mencione qu&#233; Qd es m&#225;s adecuado en HDFOL valorando sus efectos sobre el Kt o el VI&#46; Usar un Qd elevado supone un mayor consumo de agua y de concentrados&#44; de modo que esta medida solo deber&#237;a usarse si se consigue mejorar el resultado de las di&#225;lisis en cuanto a Kt o VI&#46; El cuidado de los recursos naturales es vital para la sociedad y en los &#250;ltimos a&#241;os se ha tomado plenamente conciencia de la verdadera necesidad de cuidar el agua&#46; En muchos lugares del mundo el agua es un bien escaso y&#44; aunque en las unidades de HD se deber&#237;a cuidar su consumo&#44; en la mayor&#237;a se desperdician grandes vol&#250;menes<a class="elsevierStyleCrossRef" href="#bib0220"><span class="elsevierStyleSup">19</span></a>&#46; Para mejorar&#44; se han propuesto varias soluciones como reciclar el agua rechazada&#44; aunque una medida inicial y b&#225;sica es no utilizar el agua de forma innecesaria&#46; Saber qu&#233; Qd es el &#243;ptimo en HDFOL pasa a convertirse en un objetivo b&#225;sico para lograr un consumo m&#225;s racional de agua&#46;En el presente estudio nos planteamos estudiar el efecto que tiene el Qd sobre el Kt y el VI en HDFOL&#46;</p><span id="sec0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0075">Objetivos</span><p id="par0020" class="elsevierStylePara elsevierViewall"><ul class="elsevierStyleList" id="lis0005"><li class="elsevierStyleListItem" id="lsti0005"><span class="elsevierStyleLabel">1&#46;</span><p id="par0025" class="elsevierStylePara elsevierViewall">Estudiar la influencia del Qd &#40;500&#44; 600 y 700<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#41; en el Kt y VI en HDFOL&#46;</p></li><li class="elsevierStyleListItem" id="lsti0010"><span class="elsevierStyleLabel">2&#46;</span><p id="par0030" class="elsevierStylePara elsevierViewall">Cuantificar el ahorro de agua que conlleva&#46;</p></li></ul></p></span><span id="sec0010" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0080">Material y m&#233;todos</span><p id="par0035" class="elsevierStylePara elsevierViewall">Se trata de un estudio prospectivo realizado en un &#250;nico centro de di&#225;lisis&#44; con un dise&#241;o cruzado&#46; Los sujetos incluidos deb&#237;an ser mayores de 18 a&#241;os y llevar en HDFOL m&#225;s de 3 meses&#46;</p><p id="par0040" class="elsevierStylePara elsevierViewall">Los datos demogr&#225;ficos recogidos fueron&#58; sexo&#44; edad&#44; tiempo en HD y etiolog&#237;a de la enfermedad renal&#46; Se calcul&#243; el Kt objetivo &#40;Ktobj&#41; individual ajustado a la SC&#46;</p><p id="par0045" class="elsevierStylePara elsevierViewall">Se incluy&#243; a 37 pacientes &#40;16 mujeres y 21 hombres&#41;&#46; Los monitores y dializadores fueron id&#233;nticos a lo largo de todo el estudio&#46; Un total de 16 pacientes fueron dializados con AK 200<span class="elsevierStyleSup">&#174;</span> y 21 con Fresenius 5008<span class="elsevierStyleSup">&#174;</span>&#46; Las membranas utilizadas fueron distribuidas de la siguiente manera&#58; 20 FX800<span class="elsevierStyleSup">&#174;</span> y 17 Polyflux 210H<span class="elsevierStyleSup">&#174;</span>&#46;Todos los pacientes fueron dializados en HDFOL tal y como sigue&#58;<ul class="elsevierStyleList" id="lis0010"><li class="elsevierStyleListItem" id="lsti0015"><span class="elsevierStyleLabel">-</span><p id="par0050" class="elsevierStylePara elsevierViewall">6 sesiones con Qd a 500<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#46;</p></li><li class="elsevierStyleListItem" id="lsti0020"><span class="elsevierStyleLabel">-</span><p id="par0055" class="elsevierStylePara elsevierViewall">6 sesiones con Qd a 600<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#46;</p></li><li class="elsevierStyleListItem" id="lsti0025"><span class="elsevierStyleLabel">-</span><p id="par0060" class="elsevierStylePara elsevierViewall">6 sesiones con Qd a 700<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#46;</p></li></ul></p><p id="par0065" class="elsevierStylePara elsevierViewall">Se mantuvieron durante todo el periodo&#58; el tiempo de di&#225;lisis&#44; la anticoagulaci&#243;n y el flujo de sangre&#46; Los vol&#250;menes de ultrafiltraci&#243;n fueron ajustados de acuerdo con las necesidades cl&#237;nicas&#46; Cuando el sistema 5008<span class="elsevierStyleSup">&#174;</span> mide la recirculaci&#243;n&#44; el Qd se incrementa temporalmente a 800<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#46; Nuestro trabajo rutinario mide la recirculaci&#243;n una vez en la sesi&#243;n&#46;</p><p id="par0070" class="elsevierStylePara elsevierViewall">Se recogieron directamente desde la pantalla del monitor los siguientes par&#225;metros&#58; flujo de sangre efectivo &#40;Qbe&#41;&#44; el Qd&#44; el tiempo efectivo de di&#225;lisis&#44; Kt final &#40;Ktf&#41; y VI final&#46;</p><p id="par0075" class="elsevierStylePara elsevierViewall">A partir de los datos recogidos&#44; se calcularon&#58;<ul class="elsevierStyleList" id="lis0015"><li class="elsevierStyleListItem" id="lsti0030"><span class="elsevierStyleLabel">1&#46;</span><p id="par0080" class="elsevierStylePara elsevierViewall">Los valores medios individuales de Qbe&#44; tiempo efectivo de di&#225;lisis&#44; VI y Ktf con cada Qd&#46;</p></li><li class="elsevierStyleListItem" id="lsti0035"><span class="elsevierStyleLabel">2&#46;</span><p id="par0085" class="elsevierStylePara elsevierViewall">Diferencias de Kt&#58; Ktobj-Ktf&#46;</p></li><li class="elsevierStyleListItem" id="lsti0040"><span class="elsevierStyleLabel">3&#46;</span><p id="par0090" class="elsevierStylePara elsevierViewall">Diferencias de VI &#40;objetivo&#160;&#61; 24 l&#41;&#58; VIobj-VI final&#46;</p></li></ul></p><span id="sec0015" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0085">Estad&#237;stica</span><p id="par0095" class="elsevierStylePara elsevierViewall">Las variables cualitativas se muestran con porcentajes y las variables cuantitativas como medias &#40;desviaci&#243;n est&#225;ndar&#41; o medianas &#40;m&#237;nimo-m&#225;ximo&#41;&#46; Los estudios de t-pareada y Anova fueron utilizados para comparar variables cuantitativas&#46; Los test chi-cuadrado fueron utilizados para las variables cualitativas&#46; Un valor de p menor de 0&#44;05 fue considerado como estad&#237;sticamente significativo&#46;Los an&#225;lisis fueron realizados con el programa inform&#225;tico SPSS versi&#243;n 15&#46;0&#46;</p></span></span><span id="sec0020" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0090">Resultados</span><p id="par0100" class="elsevierStylePara elsevierViewall">Los 37 pacientes incluidos ten&#237;an una mediana de edad de 67&#44;4 a&#241;os &#40;36-92&#41;&#46; La etiolog&#237;a de la ERC era&#58; 13 diabetes mellitus&#44; 7 glomerular&#44; 6 desconocida&#44; 5 vascular&#44; 4 intersticial y 2 poliqu&#237;sticos&#46; Un total de 36 se dializaban 3 veces a la semana y un paciente 2 veces a la semana por tener buena funci&#243;n renal residual&#44; que definimos como un aclaramiento medio de urea y creatinina en orina de 24&#160;h superior a 5<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#46; La duraci&#243;n de la di&#225;lisis programada fue 240<span class="elsevierStyleHsp" style=""></span>min en 7 pacientes&#44; 255<span class="elsevierStyleHsp" style=""></span>min en 25 pacientes&#44; 270<span class="elsevierStyleHsp" style=""></span>min en 4 pacientes y 300<span class="elsevierStyleHsp" style=""></span>min para un paciente&#46; Treinta pacientes se dializaban con f&#237;stula y el resto con cat&#233;ter tunelizado&#46;</p><p id="par0105" class="elsevierStylePara elsevierViewall">Recogimos 565 sesiones&#58; 192 con 500<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#44; 194 con 600<span class="elsevierStyleHsp" style=""></span>ml&#47;min y 179 con 700<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#46; Se excluyeron las sesiones en las que exist&#237;a desviaci&#243;n en el tiempo de tratamiento prescrito&#44; en el Qb o en las que por problemas t&#233;cnicos no se hab&#237;a medido K&#46; Todos los pacientes se hicieron al menos 3 sesiones con cada Qd&#46;</p><span id="sec0025" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0095">Eficacia de la di&#225;lisis</span><p id="par0110" class="elsevierStylePara elsevierViewall">La <a class="elsevierStyleCrossRef" href="#tbl0020">tabla 1</a> muestra los resultados obtenidos respecto al Kt y VI&#58; Kt ligeramente m&#225;s alto si el Qd era m&#225;s elevado y lo contrario con el VI&#46; El Kt se increment&#243; un 1&#44;7&#37; &#40;500 frente a 600 o 700<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#41;&#46; No se encontraron diferencias en el Qbe entre los diferentes Qd utilizados&#44; aunque el tiempo efectivo era un minuto inferior con un Qd de 700<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#46;</p><elsevierMultimedia ident="tbl0020"></elsevierMultimedia><p id="par0115" class="elsevierStylePara elsevierViewall">En el estudio de la adecuaci&#243;n individual&#44; el Ktobj medio era 49&#160;&#40;4&#44;2&#41; L &#40;36-56&#44;7&#160;L&#41;&#46; En la <a class="elsevierStyleCrossRef" href="#tbl0020">tabla 1</a> aparece la diferencia entre el Kt alcanzado y el objetivo&#44; con un Kt alcanzado muy por encima del Ktobj ajustado a SC con todos los Qd&#46; Solo un paciente no alcanz&#243; el Ktobj por problemas con su acceso vascular y no logr&#243; alcanzarlo con ninguno de los Qd empleados&#46;</p><p id="par0120" class="elsevierStylePara elsevierViewall">No se alcanzaron los 24&#160;L en&#58; 2 pacientes con 500<span class="elsevierStyleHsp" style=""></span>ml&#47;min &#40;VI medio&#58; 23&#44;7&#160;L&#41;&#44; 2 pacientes con 600<span class="elsevierStyleHsp" style=""></span>ml&#47;min &#40;VI&#160;medio&#58; 23&#44;8&#160;L&#41; y en 5 pacientes con 700<span class="elsevierStyleHsp" style=""></span>ml&#47;min &#40;VI 23&#44;2&#160;L&#41;&#46; Solo un paciente tuvo un VI medio &#171;bajo&#187; &#40;20&#160;L&#41;&#46; Se trata de un paciente con una amputaci&#243;n bilateral supracond&#237;lea&#44; que se dializa por un cat&#233;ter tunelizado con problemas para lograr Qb superiores a 350<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#46; No existieron diferencias estad&#237;sticamente significativas entre los que no y s&#237; alcanzaban VI con Qd&#61;700<span class="elsevierStyleHsp" style=""></span>ml&#47;min &#40;el grupo m&#225;s numeroso&#41; ni en Kt ni tiempo efectivo&#44; aunque el Qbe tend&#237;a a ser inferior 376&#44;5 &#40;39&#44;3&#41; vs&#46; 393 &#40;35&#44;2&#41; ml&#47;min&#46; Todos se dializaban en un monitor 5008<span class="elsevierStyleSup">&#174;</span>&#46;</p></span><span id="sec0030" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0100">Diferencias seg&#250;n monitor</span><p id="par0125" class="elsevierStylePara elsevierViewall">Separamos el resultado por monitores bas&#225;ndonos en los diferentes m&#233;todos utilizados para controlar el volumen convectivo y los resultados pueden verse en la <a class="elsevierStyleCrossRef" href="#tbl0025">tabla 2</a>&#46; Con ambos monitores la tendencia es a un Kt m&#225;s elevado con Qd m&#225;s elevado&#46; En cambio&#44; en el VI&#44; mientras con el monitor Fresenius<span class="elsevierStyleSup">&#174;</span> el VI es similar con cualquier Qd&#44; en el monitor Gambro<span class="elsevierStyleSup">&#174;</span> el VI era ligeramente inferior si se usaba un Qd m&#225;s alto&#46;</p><elsevierMultimedia ident="tbl0025"></elsevierMultimedia></span><span id="sec0035" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0105">Consumo de l&#237;quido de di&#225;lisis</span><p id="par0130" class="elsevierStylePara elsevierViewall">El consumo calculado de &#225;cido y LD en una sesi&#243;n de 255 min aparece en la <a class="elsevierStyleCrossRef" href="#tbl0015">tabla 3</a>&#46; As&#237; con 600<span class="elsevierStyleHsp" style=""></span>ml&#47;min se necesita un 20&#37; y con 700<span class="elsevierStyleHsp" style=""></span>ml&#47;min un 40&#37; m&#225;s de LD que con 500<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#46;</p><elsevierMultimedia ident="tbl0015"></elsevierMultimedia><p id="par0135" class="elsevierStylePara elsevierViewall">En la <a class="elsevierStyleCrossRef" href="#tbl0015">tabla 3</a> hemos reflejado el exceso de consumo que supone usar 600 o 700 vs&#46; 500<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#44; no solo por paciente sino en el total de una unidad como la nuestra con 75 enfermos&#46; Es importante resaltar que este consumo hace referencia al LD&#44; no al consumo global de agua&#44; que ser&#237;a cerca del doble&#44; ya que para formar un litro de LD ultrapuro se precisa desechar entre 0&#44;5 y 1&#160;L de agua en el proceso de tratamiento&#46;</p><p id="par0140" class="elsevierStylePara elsevierViewall">Hemos realizado un c&#225;lculo parcial del coste de un litro de LD &#40;agua&#43;&#225;cido&#41; para poder calcular el ahorro econ&#243;mico que supondr&#237;a&#46; As&#237; un litro de LD cuesta 0&#44;03 euros en el monitor Fresenius y 0&#44;02 en Gambro&#44; a coste local&#46; En la <a class="elsevierStyleCrossRef" href="#tbl0015">tabla 3</a> se incluye el ahorro econ&#243;mico que supone por paciente&#47;a&#241;o disminuir el Qd&#46;</p></span></span><span id="sec0040" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0110">Discusi&#243;n</span><p id="par0145" class="elsevierStylePara elsevierViewall">El principal resultado de nuestro trabajo es que aumentar el Qd en HDFOL logra una peque&#241;a mejor&#237;a en el Kt y no tiene influencia pr&#225;ctica en el VI&#46; Aunque el resultado pueda ser estad&#237;sticamente significativo&#44; la relevancia cl&#237;nica de estas diferencias es m&#225;s que cuestionable&#44; m&#225;xime si se tiene en cuenta el consumo de agua necesario para lograrlo&#46;</p><p id="par0150" class="elsevierStylePara elsevierViewall">La informaci&#243;n existente sobre la utilidad de usar un Qd determinado en HDFOL es pr&#225;cticamente nula&#46; En la mayor&#237;a de las unidades se utiliza un Qd de 700<span class="elsevierStyleHsp" style=""></span>ml&#47;min con la idea de aumentar la eficacia del transporte difusivo&#44; pero la base de este uso no est&#225; fundamentada&#46; De hecho&#44; solo hemos encontrado un trabajo acerca del efecto del Qd en la HDFOL&#46; Este trabajo compara HD con HDFOL utilizando autoflujo &#40;AF&#41;&#44; sistema que incorporan los monitores 5008<span class="elsevierStyleSup">&#174;</span> en los que el Qd se ajusta al Qb&#46; Los autores concluyen que con la HDFOL se puede obtener un mejor Kt&#47;V usando menos LD que en HD<a class="elsevierStyleCrossRef" href="#bib0225"><span class="elsevierStyleSup">20</span></a>&#46; Pero no hemos encontrado publicaciones en las que se compare el efecto que tienen distintos Qd sobre la eficacia o el VI en HDFOL&#44; lo que da a nuestro trabajo un car&#225;cter novedoso y eminente pr&#225;ctico&#46; Nuestros resultados muestran que&#44; al igual que ocurre en la HD&#44; aumentar el Qd tiene un m&#237;nimo efecto sobre la eficacia de la HD&#44; dato que es mucho m&#225;s relevante si se tiene en cuenta que no est&#225; basado en el Kt&#47;V calculado con las concentraciones de urea pre- y posdi&#225;lisis o el V introducido en el monitor&#46; Nuestra medida de adecuaci&#243;n se basa en el Kt ajustado a SC&#44; que es una forma tremendamente exigente<a class="elsevierStyleCrossRef" href="#bib0230"><span class="elsevierStyleSup">21</span></a>&#46; Con ello&#44; solo en un paciente con problemas de FAV no se logr&#243; el objetivo con ninguno de los Qd utilizados&#44; por lo que no parece que aumentar el Qd sea una medida &#250;til para mejorarlo&#46; Este resultado aboga por no utilizar Qd elevados en la HDFOL con el objetivo de aumentar la eficacia como cl&#225;sicamente se ha indicado&#44; m&#225;xime teniendo en cuenta que la disminuci&#243;n de la mortalidad con esta t&#233;cnica se relaciona con la cantidad de volumen convectivo administrado&#46; Se podr&#237;a alegar que con el Qb&#160;&#61;&#160;700<span class="elsevierStyleHsp" style=""></span>ml&#47;min el tiempo efectivo era menor y que al igualar esa diferencia de tiempo se lograr&#237;a aumentar m&#225;s Kt&#46; Dado que todos sabemos que prolongar el tiempo se asocia a una mejor supervivencia independientemente de la dosis de di&#225;lisis<a class="elsevierStyleCrossRef" href="#bib0235"><span class="elsevierStyleSup">22</span></a>&#44; habr&#237;a que poner en la balanza el efecto de p&#233;rdida de tiempo&#44; posiblemente por controles internos de la m&#225;quina vs&#46; mejor&#237;a del Kt y&#44; dado que ambas diferencias son m&#237;nimas y posiblemente poco relevantes&#44; creemos que usar un Qd superior a 500<span class="elsevierStyleHsp" style=""></span>ml&#47;min no es una medida eficaz&#46;</p><p id="par0155" class="elsevierStylePara elsevierViewall">En cuanto al VI&#44; como era l&#243;gico&#44; el Qd pr&#225;cticamente no tiene influencia&#46; Hoy en d&#237;a las t&#233;cnicas autom&#225;ticas de HDFOL intentan conseguir un mayor rendimiento de transporte convectivo&#44; pero cada monitor tiene diferentes sistemas de control y obtiene resultados diferentes&#46; De hecho &#171;regulan&#187; el VI bas&#225;ndose en m&#233;todos que los nefr&#243;logos no siempre conocemos&#46; En cualquier caso&#44; parece claro que usar Qd elevados no tiene repercusi&#243;n ni utilidad para modificar el VI en la HDFOL&#46; Cuando estudiamos si se logran los objetivos&#44; solo un enfermo quedaba lejos de lograr los 24&#160;l fijados &#40;obteniendo en torno a 20&#160;l&#41; por un problema de Qb al dializarse por un CT&#46; Es interesante tener en cuenta que este paciente ten&#237;a una amputaci&#243;n supracond&#237;lea bilateral&#46; En el momento actual no contamos con ninguna forma de hacer una prescripci&#243;n individualizada de VI&#44; como ocurre con el Kt&#44; de acuerdo con la SC&#46; Este hecho nos sirve para reflexionar sobre la necesidad de conocer cu&#225;l es el objetivo de VI para cada paciente y desarrollar as&#237; una HDFOL plenamente individualizada&#46; Para el resto de los que no lo lograban&#44; aunque estaban cerca&#44; el hecho no depend&#237;a tampoco del Qd utilizado&#46; Eran pacientes con un VI muy ajustado a 24&#160;l y quienes&#44; posiblemente aumentando el Qb o el tiempo o revisando si se puede conseguir mejor rendimiento con otro m&#233;todo&#44; lo alcanzar&#237;an independientemente del Qd&#46; Finalmente cabe recordar que muchos trabajos incluyen en el volumen convectivo el VI m&#225;s el volumen de ultrafiltraci&#243;n pautado para lograr el peso seco&#46; Nosotros no hemos sumado el volumen de ultrafiltraci&#243;n&#44; con lo que habr&#237;amos alcanzado el objetivo de los 24&#160;l&#46;</p><p id="par0160" class="elsevierStylePara elsevierViewall">No comparamos el Kt ni VI que se obten&#237;a con diferentes monitores&#44; ya que no era el objetivo de nuestro estudio ni estaba dise&#241;ado para ello&#46; Creemos que las diferencias observadas en la <a class="elsevierStyleCrossRef" href="#tbl0025">tabla 2</a> en cuanto al Kt est&#225;n de acuerdo con los resultados del trabajo publicado por Maduell et al&#46; que ya mostraba que la dialisancia i&#243;nica calculada por los monitores Fresenius era m&#225;s elevada que la calculada por monitor AK200<span class="elsevierStyleSup">&#174;</span><a class="elsevierStyleCrossRef" href="#bib0240"><span class="elsevierStyleSup">23</span></a>&#46; Igualmente&#44; el mayor VI que logra el m&#233;todo Ultracontrol<span class="elsevierStyleSup">&#174;</span> est&#225; de acuerdo con nuestros resultados previos<a class="elsevierStyleCrossRef" href="#bib0245"><span class="elsevierStyleSup">24</span></a>&#46;</p><p id="par0165" class="elsevierStylePara elsevierViewall">El agua potable&#44; empleada para consumo humano&#44; no sirve para la fabricaci&#243;n de LD&#58; es imprescindible purificarla&#46; Para la HDFOL el aspecto del agua en el que se hace hincapi&#233; es en la obligatoriedad de utilizar un agua y LD ultrapuros&#44; haciendo menci&#243;n a su calidad pero no a su cantidad&#46; Tratar a un paciente durante varias horas 3 veces por semana requiere grandes cantidades de energ&#237;a y agua&#44; adem&#225;s de que genera productos m&#233;dicos desechables&#46; Se calcula que el balance ambiental promedio de una sesi&#243;n de HD es de aproximadamente 400-500&#160;l de agua&#44; 10 kw&#47;hora de electricidad y hasta 3 kg de desechos cl&#237;nicos<a class="elsevierStyleCrossRef" href="#bib0250"><span class="elsevierStyleSup">25</span></a>&#46; Por lo tanto&#44; en lo que respecta al LD&#44; fabricar LD ultrapuro conlleva problemas econ&#243;micos y ecol&#243;gicos&#46; Aunque nosotros hemos mostrado el LD directamente utilizado&#44; queremos insistir en que para producir ese litro&#44; otro litro se ha perdido en el proceso de tratamiento&#59; es decir&#44; para generar un litro de LD en &#243;smosis inversa se necesitan 2&#160;l de agua&#44; lo que supone el doble de consumo&#46; El agua es un elemento clave para la subsistencia de la vida&#44; y su manejo es hoy absolutamente necesario desde la perspectiva del buen uso de los recursos naturales&#58; es necesario aumentar la conciencia sobre temas ambientales entre el personal de la cl&#237;nica de di&#225;lisis&#46; Si pensamos en una sesi&#243;n de 255<span class="elsevierStyleHsp" style=""></span>min&#44; bajar de 700 a 500<span class="elsevierStyleHsp" style=""></span>ml&#47;min y ahorrar 51&#160;l de LD en cada paciente puede parecer poco relevante&#44; pero implica en una unidad de 75 pacientes m&#225;s de 500&#46;000&#160;l de LD en un a&#241;o o&#44; como hemos explicado&#44; 1&#46;000&#46;000&#160;l de agua potable&#44; adem&#225;s del ahorro de &#225;cido&#44; con la consiguiente ventaja econ&#243;mica y ecol&#243;gica&#46; A este beneficio ecol&#243;gico hay que sumar el econ&#243;mico&#46; Hemos realizado una valoraci&#243;n del coste de un litro de LD teniendo en cuenta el agua m&#225;s el &#225;cido&#46; No se ha sumado el bicarbonato&#44; ya que asumimos que utilizamos un cartucho por sesi&#243;n con cualquier Qd&#44; para facilitar el c&#225;lculo&#44; aunque en ocasiones es necesario pasar a usar un cartucho con mayor cantidad de bicarbonato y&#44; por tanto mayor precio&#44; al aumentar el Qd&#46; Aunque a simple vista el precio de un litro parece desde&#241;able&#44; se pone de relieve la importancia si tenemos en cuenta el consumo sobre una n&#58; anual&#46; Adem&#225;s&#44; nuestros c&#225;lculos no han tenido en cuenta el agua consumida durante la preparaci&#243;n ni la desinfecci&#243;n &#40;por lo que el ahorro podr&#237;a ser mayor si se optimizasen esos consumos&#41;&#44; ni otros gastos de mantenimiento de la planta de tratamiento de agua&#44; que parcialmente se pueden ver afectados por un mayor consumo de agua&#46;</p><p id="par0170" class="elsevierStylePara elsevierViewall">La principal limitaci&#243;n de nuestro estudio es que el n&#250;mero de pacientes incluido es peque&#241;o&#44; pero el n&#250;mero de sesiones de di&#225;lisis es suficiente y el dise&#241;o cruzado permite comparar cada paciente consigo mismo&#44; lo que refuerza los resultados&#46; Tambi&#233;n nuestro estudio ha sido realizado en una &#250;nica unidad de di&#225;lisis pero pensamos que nuestros resultados pueden ser extrapolados a todas las unidades que trabajan en condiciones similares&#46;</p></span><span id="sec0045" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0115">Conclusiones</span><p id="par0175" class="elsevierStylePara elsevierViewall">Nuestros datos indican que aumentar el Qd por encima de 500<span class="elsevierStyleHsp" style=""></span>ml&#47;min en HDFOL ofrece un beneficio limitado&#46; Mejorar la eficacia de di&#225;lisis ahorrando agua es importante para el medio ambiente y para satisfacer la demanda humana actual y futura&#44; logrando as&#237; una di&#225;lisis mucho m&#225;s eficiente&#46; Si utilizar Qd inferiores es factible es el terreno que queda por estudiar&#46;</p></span><span id="sec0050" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0120">Conflicto de intereses</span><p id="par0180" class="elsevierStylePara elsevierViewall">El Dr&#46; P&#233;rez Garc&#237;a&#44; la Dra&#46; de Sequera y la Dra&#46; M&#46; Albalate han participado en reuniones de Fresenius y Gambro&#46;</p></span></span>"
    "textoCompletoSecciones" => array:1 [
      "secciones" => array:12 [
        0 => array:3 [
          "identificador" => "xres590776"
          "titulo" => "Resumen"
          "secciones" => array:5 [
            0 => array:2 [
              "identificador" => "abst0005"
              "titulo" => "Introducci&#243;n"
            ]
            1 => array:2 [
              "identificador" => "abst0010"
              "titulo" => "Objetivo"
            ]
            2 => array:2 [
              "identificador" => "abst0015"
              "titulo" => "Material y m&#233;todos"
            ]
            3 => array:2 [
              "identificador" => "abst0020"
              "titulo" => "Resultados"
            ]
            4 => array:2 [
              "identificador" => "abst0025"
              "titulo" => "Conclusiones"
            ]
          ]
        ]
        1 => array:2 [
          "identificador" => "xpalclavsec606363"
          "titulo" => "Palabras clave"
        ]
        2 => array:3 [
          "identificador" => "xres590777"
          "titulo" => "Abstract"
          "secciones" => array:5 [
            0 => array:2 [
              "identificador" => "abst0030"
              "titulo" => "Introduction"
            ]
            1 => array:2 [
              "identificador" => "abst0035"
              "titulo" => "Objective"
            ]
            2 => array:2 [
              "identificador" => "abst0040"
              "titulo" => "Material and methods"
            ]
            3 => array:2 [
              "identificador" => "abst0045"
              "titulo" => "Results"
            ]
            4 => array:2 [
              "identificador" => "abst0050"
              "titulo" => "Conclusions"
            ]
          ]
        ]
        3 => array:2 [
          "identificador" => "xpalclavsec606364"
          "titulo" => "Keywords"
        ]
        4 => array:2 [
          "identificador" => "sec0005"
          "titulo" => "Objetivos"
        ]
        5 => array:3 [
          "identificador" => "sec0010"
          "titulo" => "Material y m&#233;todos"
          "secciones" => array:1 [
            0 => array:2 [
              "identificador" => "sec0015"
              "titulo" => "Estad&#237;stica"
            ]
          ]
        ]
        6 => array:3 [
          "identificador" => "sec0020"
          "titulo" => "Resultados"
          "secciones" => array:3 [
            0 => array:2 [
              "identificador" => "sec0025"
              "titulo" => "Eficacia de la di&#225;lisis"
            ]
            1 => array:2 [
              "identificador" => "sec0030"
              "titulo" => "Diferencias seg&#250;n monitor"
            ]
            2 => array:2 [
              "identificador" => "sec0035"
              "titulo" => "Consumo de l&#237;quido de di&#225;lisis"
            ]
          ]
        ]
        7 => array:2 [
          "identificador" => "sec0040"
          "titulo" => "Discusi&#243;n"
        ]
        8 => array:2 [
          "identificador" => "sec0045"
          "titulo" => "Conclusiones"
        ]
        9 => array:2 [
          "identificador" => "sec0050"
          "titulo" => "Conflicto de intereses"
        ]
        10 => array:2 [
          "identificador" => "xack198752"
          "titulo" => "Agradecimientos"
        ]
        11 => array:1 [
          "titulo" => "Bibliograf&#237;a"
        ]
      ]
    ]
    "pdfFichero" => "main.pdf"
    "tienePdf" => true
    "fechaRecibido" => "2014-12-10"
    "fechaAceptado" => "2015-04-13"
    "PalabrasClave" => array:2 [
      "es" => array:1 [
        0 => array:4 [
          "clase" => "keyword"
          "titulo" => "Palabras clave"
          "identificador" => "xpalclavsec606363"
          "palabras" => array:4 [
            0 => "Flujo de l&#237;quido de di&#225;lisis"
            1 => "Kt"
            2 => "Hemodiafiltraci&#243;n en l&#237;nea"
            3 => "Flujo de infusi&#243;n"
          ]
        ]
      ]
      "en" => array:1 [
        0 => array:4 [
          "clase" => "keyword"
          "titulo" => "Keywords"
          "identificador" => "xpalclavsec606364"
          "palabras" => array:4 [
            0 => "Dialysate flow rate"
            1 => "Kt"
            2 => "Hemodiafiltration on-line"
            3 => "Infusion volume"
          ]
        ]
      ]
    ]
    "tieneResumen" => true
    "resumen" => array:2 [
      "es" => array:3 [
        "titulo" => "Resumen"
        "resumen" => "<span id="abst0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0010">Introducci&#243;n</span><p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">En la hemodiafiltraci&#243;n en l&#237;nea posdilucional &#40;HDFOL&#41; la &#250;nica recomendaci&#243;n acerca del l&#237;quido de di&#225;lisis &#40;LD&#41; hace referencia a su pureza&#46; No se ha definido si usar flujos de ba&#241;o &#40;Qd&#41; elevados tiene alguna utilidad para aumentar el Kt o el volumen de ultrafiltraci&#243;n-infusi&#243;n &#40;VI&#41;&#46;</p></span> <span id="abst0010" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0015">Objetivo</span><p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">Estudiar c&#243;mo influye el Qd en el Kt y en el VI en la HDFOL&#46;</p></span> <span id="abst0015" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0020">Material y m&#233;todos</span><p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">Estudio cruzado prospectivo&#46; Se incluy&#243; a 37 pacientes a los que se les realizaron 6 sesiones de HDFOL con cada Qd&#58; 500&#44; 600 y 700<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#46; Veinti&#250;n pacientes se dializaron en monitor 5008<span class="elsevierStyleSup">&#174;</span> y 17 con AK-200<span class="elsevierStyleSup">&#174;</span>&#46; Los dializadores utilizados fueron&#58; 20 con FX800<span class="elsevierStyleSup">&#174;</span> y 17 con Polyflux-210<span class="elsevierStyleSup">&#174;</span>&#46; El resto de los par&#225;metros se mantuvieron constantes&#46; Se recogieron del monitor&#58; flujo efectivo de sangre&#44; tiempo efectivo de di&#225;lisis&#44; Kt final y VI&#46;</p></span> <span id="abst0020" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0025">Resultados</span><p id="spar0020" class="elsevierStyleSimplePara elsevierViewall">Encontramos que usando un Qd<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>600 o 700<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#44; el Kt aument&#243; un 1&#44;7&#37; respecto al uso de Qd<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>500<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#46; Las diferencias de VI no fueron significativas&#46;</p><p id="spar0025" class="elsevierStyleSimplePara elsevierViewall">Aumentar el Qd de 500<span class="elsevierStyleHsp" style=""></span>ml&#47;min a 600 y 700<span class="elsevierStyleHsp" style=""></span>ml&#47;min aumenta el consumo de LD un 20 y un 40&#37;&#44; respectivamente&#46;</p></span> <span id="abst0025" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0030">Conclusiones</span><p id="spar0030" class="elsevierStyleSimplePara elsevierViewall">En la HDFOL con los monitores y dializadores utilizados no son &#250;tiles los Qd superiores a 500<span class="elsevierStyleHsp" style=""></span>ml&#47;min para aumentar la eficacia del Kt ni el VI&#44; por lo que su utilizaci&#243;n implica un despilfarro de un recurso como el agua&#44; tan importante tanto desde el punto de vista ecol&#243;gico como econ&#243;mico&#46;</p></span>"
        "secciones" => array:5 [
          0 => array:2 [
            "identificador" => "abst0005"
            "titulo" => "Introducci&#243;n"
          ]
          1 => array:2 [
            "identificador" => "abst0010"
            "titulo" => "Objetivo"
          ]
          2 => array:2 [
            "identificador" => "abst0015"
            "titulo" => "Material y m&#233;todos"
          ]
          3 => array:2 [
            "identificador" => "abst0020"
            "titulo" => "Resultados"
          ]
          4 => array:2 [
            "identificador" => "abst0025"
            "titulo" => "Conclusiones"
          ]
        ]
      ]
      "en" => array:3 [
        "titulo" => "Abstract"
        "resumen" => "<span id="abst0030" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0040">Introduction</span><p id="spar0035" class="elsevierStyleSimplePara elsevierViewall">In post-dilution online hemodiafiltration &#40;OL-HDF&#41;&#44; the only recommendation concerning the dialysate&#44; or dialysis fluid&#44; refers to its purity&#46; No study has yet determined whether using a high dialysate flow &#40;Qd&#41; is useful for increasing Kt or ultrafiltration-infusion volume&#46;</p></span> <span id="abst0035" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0045">Objective</span><p id="spar0040" class="elsevierStyleSimplePara elsevierViewall">Study the influence of Qd on Kt and on infusion volume in OL-HDF&#46;</p></span> <span id="abst0040" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0050">Material and methods</span><p id="spar0045" class="elsevierStyleSimplePara elsevierViewall">This was a prospective crossover study&#46; There were 37 patients to whom 6 sessions of OL-HDF were administered at 3 different Qds&#58; 500&#44; 600 and 700<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#46; A 5008<span class="elsevierStyleSup">&#174;</span> monitor was used for the dialysis in 21 patients&#44; while an AK-200<span class="elsevierStyleSup">&#174;</span> was used in 17&#46; The dialysers used were&#58; 20 with FX 800<span class="elsevierStyleSup">&#174;</span> and 17 with Polyflux-210<span class="elsevierStyleSup">&#174;</span>&#46; The rest of the parameters were kept constant&#46; Monitor data collected were effective blood flow&#44; effective dialysis time&#44; final Kt and infused volume&#46;</p></span> <span id="abst0045" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0055">Results</span><p id="spar0050" class="elsevierStyleSimplePara elsevierViewall">We found that using a Qd of 600 or 700<span class="elsevierStyleHsp" style=""></span>ml&#47;min increased Kt by 1&#46;7&#37; compared to using a Qd of 500<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#46; Differences in infusion volume were not significant&#46; Increasing Qd from 500<span class="elsevierStyleHsp" style=""></span>ml&#47;min to 600 and 700<span class="elsevierStyleHsp" style=""></span>ml&#47;min increased dialysate consumption by 20&#37; and 40&#37;&#44; respectively&#46;</p></span> <span id="abst0050" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0060">Conclusions</span><p id="spar0055" class="elsevierStyleSimplePara elsevierViewall">With the monitors and dialysers currently used in OL-HDF&#44; a Qd higher than 500<span class="elsevierStyleHsp" style=""></span>ml&#47;min is unhelpful for increasing the efficacy of Kt or infusion volume&#46; Consequently&#44; using a high Qd wastes water&#44; a truly important resource both from the ecological and economic points of view&#46;</p></span>"
        "secciones" => array:5 [
          0 => array:2 [
            "identificador" => "abst0030"
            "titulo" => "Introduction"
          ]
          1 => array:2 [
            "identificador" => "abst0035"
            "titulo" => "Objective"
          ]
          2 => array:2 [
            "identificador" => "abst0040"
            "titulo" => "Material and methods"
          ]
          3 => array:2 [
            "identificador" => "abst0045"
            "titulo" => "Results"
          ]
          4 => array:2 [
            "identificador" => "abst0050"
            "titulo" => "Conclusions"
          ]
        ]
      ]
    ]
    "multimedia" => array:3 [
      0 => array:7 [
        "identificador" => "tbl0020"
        "etiqueta" => "Tabla 1"
        "tipo" => "MULTIMEDIATABLA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "tabla" => array:2 [
          "leyenda" => "<p id="spar0100" class="elsevierStyleSimplePara elsevierViewall">DifKtobj&#58; diferencia entre el Kt objetivo y Kt final con los diferentes Qd&#44; Abreviaturas&#58; M&#58; media&#44; DE&#58; desviaci&#243;n est&#225;ndar a&#58; 500<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#44; b&#58; 600<span class="elsevierStyleHsp" style=""></span>ml&#47;min y c&#58; 700<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#46; En la columna de la derecha se se&#241;alan las diferencias significativas entre cada pares de grupos &#40;prueba post-hoc&#41;&#46;</p>"
          "tablatextoimagen" => array:1 [
            0 => array:2 [
              "tabla" => array:1 [
                0 => """
                  <table border="0" frame="\n
                  \t\t\t\t\tvoid\n
                  \t\t\t\t" class=""><thead title="thead"><tr title="table-row"><th class="td" title="table-head  " align="left" valign="top" scope="col" style="border-bottom: 2px solid black">Qd&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th><th class="td" title="table-head  " align="left" valign="top" scope="col" style="border-bottom: 2px solid black">500<span class="elsevierStyleHsp" style=""></span>ml&#47;min &#40;a&#41;M &#40;DE&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th><th class="td" title="table-head  " align="left" valign="top" scope="col" style="border-bottom: 2px solid black">600<span class="elsevierStyleHsp" style=""></span>ml&#47;min &#40;b&#41;M &#40;DE&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th><th class="td" title="table-head  " align="left" valign="top" scope="col" style="border-bottom: 2px solid black">700<span class="elsevierStyleHsp" style=""></span>ml&#47;min &#40;c&#41;M &#40;DE&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th><th class="td" title="table-head  " align="left" valign="top" scope="col" style="border-bottom: 2px solid black">p post-hoc&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th></tr></thead><tbody title="tbody"><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Tiempo efectivo &#40;min&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">246&#44;7&#40;9&#44;6&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">246&#44;3 &#40;10&#44;0&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">245&#44;0 &#40;10&#44;0&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="left" valign="top">&#60;0&#44;010 a&#44;cb&#44;c&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Qb efectivo &#40;ml&#47;min&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">390&#44;0 &#40;33&#44;6&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">388&#44;8 &#40;34&#44;7&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">387&#44;9 &#40;37&#44;0&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="left" valign="top">NS&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Kt &#40;L&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">61&#44;4 &#40;5&#44;9&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">62&#44;5 &#40;6&#44;5&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">62&#44;9 &#40;7&#44;2&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="left" valign="top">&#60;0&#44;005 a&#44;c&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">DifKtobj &#40;L&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">12&#44;4 &#40;6&#44;0&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">13&#44;4 &#40;6&#44;4&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">13&#44;3 &#40;8&#44;0&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="left" valign="top">NS&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">VI &#40;L&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">27&#44;7 &#40;3&#44;1&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">27&#44;7 &#40;3&#44;2&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">27&#44;1 &#40;3&#44;4&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="left" valign="top">&#60;0&#44;009 a&#44;c&#60;0&#44;010 b&#44;c&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr></tbody></table>
                  """
              ]
              "imagenFichero" => array:1 [
                0 => "xTab965041.png"
              ]
            ]
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p id="spar0095" class="elsevierStyleSimplePara elsevierViewall">Resultados de la HDFOL con los diferentes Qd</p>"
        ]
      ]
      1 => array:7 [
        "identificador" => "tbl0025"
        "etiqueta" => "Tabla 2"
        "tipo" => "MULTIMEDIATABLA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "tabla" => array:1 [
          "tablatextoimagen" => array:1 [
            0 => array:2 [
              "tabla" => array:1 [
                0 => """
                  <table border="0" frame="\n
                  \t\t\t\t\tvoid\n
                  \t\t\t\t" class=""><thead title="thead"><tr title="table-row"><th class="td" title="table-head  " colspan="2" align="left" valign="top" scope="col" style="border-bottom: 2px solid black">Qd</th><th class="td" title="table-head  " align="left" valign="top" scope="col" style="border-bottom: 2px solid black">500<span class="elsevierStyleHsp" style=""></span>ml&#47;min &#40;a&#41;M &#40;DE&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th><th class="td" title="table-head  " align="left" valign="top" scope="col" style="border-bottom: 2px solid black">600<span class="elsevierStyleHsp" style=""></span>ml&#47;min &#40;b&#41;M &#40;DE&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th><th class="td" title="table-head  " align="left" valign="top" scope="col" style="border-bottom: 2px solid black">700<span class="elsevierStyleHsp" style=""></span>ml&#47;min &#40;c&#41;M &#40;DE&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th><th class="td" title="table-head  " align="left" valign="top" scope="col" style="border-bottom: 2px solid black">p post-hoc&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th></tr></thead><tbody title="tbody"><tr title="table-row"><td class="td" title="table-entry  " rowspan="2" align="left" valign="top">Kt &#40;L&#41;</td><td class="td" title="table-entry  " align="left" valign="top">AK200&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">59&#44;8 &#40;6&#44;6&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">60&#44;8 &#40;7&#44;0&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">61&#44;1 &#40;7&#44;5&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="left" valign="top">&#60;0&#44;008 a&#44;b&#60;0&#44;020 a&#44;c&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">5008&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">62&#44;7 &#40;5&#44;1&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">63&#44;8 &#40;5&#44;9&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">64&#44;1 &#40;7&#44;0&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="left" valign="top">&#60;0&#44;020 a&#44;b&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="table-entry  " rowspan="2" align="left" valign="top">VI &#40;L&#41;</td><td class="td" title="table-entry  " align="left" valign="top">AK200&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">28&#44;9 &#40;3&#44;1&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">29&#44;0 &#40;3&#44;3&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">28&#44;0 &#40;3&#44;3&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="left" valign="top">&#60;0&#44;040 a&#44;c&#60;0&#44;040 b&#44;c&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">5008&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">26&#44;9 &#40;3&#44;0&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">26&#44;8 &#40;2&#44;8&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">26&#44;6 &#40;3&#44;7&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="left" valign="top">NS&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr></tbody></table>
                  """
              ]
              "imagenFichero" => array:1 [
                0 => "xTab965040.png"
              ]
            ]
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p id="spar0105" class="elsevierStyleSimplePara elsevierViewall">Resultados de la HDFOL-P con los diferentes monitores&#44; en la columna de la derecha se se&#241;alan las diferencias significativas entre cada pares de grupos &#40;prueba post-hoc&#41;</p>"
        ]
      ]
      2 => array:7 [
        "identificador" => "tbl0015"
        "etiqueta" => "Tabla 3"
        "tipo" => "MULTIMEDIATABLA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "tabla" => array:2 [
          "leyenda" => "<p id="spar0090" class="elsevierStyleSimplePara elsevierViewall">El exceso anual&#47;pac&#58; consumo te&#243;rico de agua al usar 600 o 700 vs&#46; 500<span class="elsevierStyleHsp" style=""></span>ml&#47;min en litros&#46;</p>"
          "tablatextoimagen" => array:1 [
            0 => array:2 [
              "tabla" => array:1 [
                0 => """
                  <table border="0" frame="\n
                  \t\t\t\t\tvoid\n
                  \t\t\t\t" class=""><thead title="thead"><tr title="table-row"><th class="td" title="table-head  " align="left" valign="top" scope="col" style="border-bottom: 2px solid black">Qd&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th><th class="td" title="table-head  " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">LD consumido &#40;l&#41; sesi&#243;n&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th><th class="td" title="table-head  " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">&#193;cido consumido &#40;l&#41;&#47;sesi&#243;n&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th><th class="td" title="table-head  " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">Exceso anual LD&#47;pac &#40;l&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th><th class="td" title="table-head  " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">Exceso anual con 75 pac &#40;l&#41;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th><th class="td" title="table-head  " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">Euros ahorrados Gambro 75 pac&#47;a&#241;o&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th><th class="td" title="table-head  " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">Euros ahorrados Fresenius 75 pac&#47;a&#241;o&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</th></tr></thead><tbody title="tbody"><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">500 ml&#47;min&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">127&#44;5&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">2&#44;8&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">-&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="" valign="top">&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="" valign="top">&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="" valign="top">&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">600 ml&#47;min&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">153&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">3&#44;4&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">4&#46;056&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">304&#46;200&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">9&#46;126&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">6&#46;084&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">700 ml&#47;min&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">178&#44;5&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">3&#44;9&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">7&#46;956&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">596&#46;700&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">17&#46;901&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="table-entry  " align="char" valign="top">11&#46;934&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr></tbody></table>
                  """
              ]
              "imagenFichero" => array:1 [
                0 => "xTab965042.png"
              ]
            ]
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p id="spar0085" class="elsevierStyleSimplePara elsevierViewall">L&#237;quido de di&#225;lisis consumido con los diferentes flujos de ba&#241;o</p>"
        ]
      ]
    ]
    "bibliografia" => array:2 [
      "titulo" => "Bibliograf&#237;a"
      "seccion" => array:1 [
        0 => array:2 [
          "identificador" => "bibs0005"
          "bibliografiaReferencia" => array:25 [
            0 => array:3 [
              "identificador" => "bib0130"
              "etiqueta" => "1"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "On-line haemodiafiltration after the ESHOL study"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:1 [
                            0 => "R&#46; P&#233;rez-Garc&#237;a"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.3265/Nefrologia.pre2014.Feb.12472"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nefrolog&#237;a"
                        "fecha" => "2014"
                        "volumen" => "34"
                        "paginaInicial" => "139"
                        "paginaFinal" => "144"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/24658188"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            1 => array:3 [
              "identificador" => "bib0135"
              "etiqueta" => "2"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Cost-effectiveness analysis of on-line hemodiafiltration in Japan"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:5 [
                            0 => "T&#46; Takura"
                            1 => "H&#46; Kawanishi"
                            2 => "J&#46; Minakuchi"
                            3 => "Y&#46; Nagake"
                            4 => "S&#46; Takahashi"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1159/000346358"
                      "Revista" => array:7 [
                        "tituloSerie" => "Blood Purif"
                        "fecha" => "2013"
                        "volumen" => "35"
                        "numero" => "Suppl 1"
                        "paginaInicial" => "85"
                        "paginaFinal" => "89"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23466387"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            2 => array:3 [
              "identificador" => "bib0140"
              "etiqueta" => "3"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "The urea &#123;clearance x dialysis time&#125; product &#40;KT&#41; as an outcome-based measure of hemodialysis dose"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:5 [
                            0 => "E&#46;G&#46; Lowrie"
                            1 => "G&#46;M&#46; Chertow"
                            2 => "N&#46;L&#46; Lew"
                            3 => "J&#46;M&#46; Lazarus"
                            4 => "W&#46;F&#46; Owen"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1046/j.1523-1755.1999.00584.x"
                      "Revista" => array:6 [
                        "tituloSerie" => "Kidney Int"
                        "fecha" => "1999"
                        "volumen" => "56"
                        "paginaInicial" => "729"
                        "paginaFinal" => "737"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/10432415"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            3 => array:3 [
              "identificador" => "bib0145"
              "etiqueta" => "4"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Evaluating a new method to judge dialysis treatment using online measurements of ionic clearance"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "E&#46;G&#46; Lowrie"
                            1 => "Z&#46; Li"
                            2 => "N&#46;J&#46; Ofsthun"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1038/sj.ki.5001507"
                      "Revista" => array:7 [
                        "tituloSerie" => "Kidney Int"
                        "fecha" => "2006"
                        "volumen" => "70"
                        "paginaInicial" => "211"
                        "paginaFinal" => "217"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/16723982"
                            "web" => "Medline"
                          ]
                        ]
                        "itemHostRev" => array:3 [
                          "pii" => "S009082581300214X"
                          "estado" => "S300"
                          "issn" => "00908258"
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            4 => array:3 [
              "identificador" => "bib0150"
              "etiqueta" => "5"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Mortality risk for patients receiving hemodiafiltration versus hemodialysis&#58; European results from the DOPPS"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "B&#46; Canaud"
                            1 => "J&#46;L&#46; Bragg-Gresham"
                            2 => "M&#46;R&#46; Marshall"
                            3 => "S&#46; Desmeules"
                            4 => "B&#46;W&#46; Gillespie"
                            5 => "T&#46; Depner"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1038/sj.ki.5000447"
                      "Revista" => array:7 [
                        "tituloSerie" => "Kidney Int"
                        "fecha" => "2006"
                        "volumen" => "69"
                        "paginaInicial" => "2087"
                        "paginaFinal" => "2093"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/16641921"
                            "web" => "Medline"
                          ]
                        ]
                        "itemHostRev" => array:3 [
                          "pii" => "S0002937813002998"
                          "estado" => "S300"
                          "issn" => "00029378"
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            5 => array:3 [
              "identificador" => "bib0155"
              "etiqueta" => "6"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Comparison of posdilution on-line hemodiafiltration and hemodialysis &#40;Turkish HDF Study&#41;"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "E&#46; Ok"
                            1 => "G&#46; Asci"
                            2 => "E&#46; Sevinc-Ok"
                            3 => "F&#46; Kircelli"
                            4 => "M&#46; Yilmaz"
                            5 => "E&#46; Hur"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1093/ndt/gfs407"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nephrol Dial Transplant"
                        "fecha" => "2013"
                        "volumen" => "28"
                        "paginaInicial" => "192"
                        "paginaFinal" => "202"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23229932"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            6 => array:3 [
              "identificador" => "bib0160"
              "etiqueta" => "7"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "CONTRAST Investigators&#58; Effect of on-line hemodiafiltration on all-cause mortality and cardiovascular outcomes"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "M&#46;P&#46; Grooteman"
                            1 => "M&#46;A&#46; van den Dorpel"
                            2 => "M&#46;L&#46; Bots"
                            3 => "E&#46;L&#46; Penne"
                            4 => "N&#46;C&#46; van der Weerd"
                            5 => "A&#46;H&#46; Mazairac"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1681/ASN.2011121140"
                      "Revista" => array:6 [
                        "tituloSerie" => "J Am Soc Nephrol"
                        "fecha" => "2012"
                        "volumen" => "23"
                        "paginaInicial" => "1087"
                        "paginaFinal" => "1096"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22539829"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            7 => array:3 [
              "identificador" => "bib0165"
              "etiqueta" => "8"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "ESHOL Study Group&#44; High-efficiency posdilution online hemodiafiltration reduces all-cause mortality in hemodialysis patients"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "F&#46; Maduell"
                            1 => "F&#46; Moreso"
                            2 => "M&#46; Pons"
                            3 => "R&#46; Ramos"
                            4 => "J&#46; Mora-Maci&#224;"
                            5 => "J&#46; Carreras"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1681/ASN.2012080875"
                      "Revista" => array:7 [
                        "tituloSerie" => "J Am Soc Nephrol"
                        "fecha" => "2013"
                        "volumen" => "24"
                        "paginaInicial" => "487"
                        "paginaFinal" => "497"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23411788"
                            "web" => "Medline"
                          ]
                        ]
                        "itemHostRev" => array:3 [
                          "pii" => "S0090825809009500"
                          "estado" => "S300"
                          "issn" => "00908258"
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            8 => array:3 [
              "identificador" => "bib0170"
              "etiqueta" => "9"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Hemodialyzer mass transfer-area coefficients for urea increase at high dialysate flow rates"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:6 [
                            0 => "J&#46;K&#46; Leypoldt"
                            1 => "A&#46;K&#46; Cheung"
                            2 => "L&#46;Y&#46; Agodoa"
                            3 => "J&#46;T&#46; Daugirdas"
                            4 => "T&#46; Greene"
                            5 => "P&#46;R&#46; Keshaviah"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Kidney Int"
                        "fecha" => "1997"
                        "volumen" => "51"
                        "paginaInicial" => "2013"
                        "paginaFinal" => "2017"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/9186896"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            9 => array:3 [
              "identificador" => "bib0175"
              "etiqueta" => "10"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Increasing dialysate flow rate increases dialyzer urea mass transfer-area coefficients during clinical use"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:2 [
                            0 => "R&#46; Ouseph"
                            1 => "R&#46;A&#46; Ward"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1053/ajkd.2001.21296"
                      "Revista" => array:6 [
                        "tituloSerie" => "Am J Kidney Dis"
                        "fecha" => "2001"
                        "volumen" => "37"
                        "paginaInicial" => "316"
                        "paginaFinal" => "320"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/11157372"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            10 => array:3 [
              "identificador" => "bib0180"
              "etiqueta" => "11"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Experimental evaluation of flow and dialysis performance of hollow-fiber dialyzers with different packing densities"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:4 [
                            0 => "A&#46; Hirano"
                            1 => "S&#46; Kida"
                            2 => "K&#46; Yamamoto"
                            3 => "K&#46; Sakai"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "J Int Organs"
                        "fecha" => "2012"
                        "volumen" => "15"
                        "paginaInicial" => "168"
                        "paginaFinal" => "175"
                        "itemHostRev" => array:3 [
                          "pii" => "S0090825812002211"
                          "estado" => "S300"
                          "issn" => "00908258"
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            11 => array:3 [
              "identificador" => "bib0185"
              "etiqueta" => "12"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Evaluation of dialyzer jacket structure and hollow-fiber dialysis membranes to achieve high dialysis performance"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "A&#46; Hirano"
                            1 => "K&#46; Yamamoto"
                            2 => "M&#46; Matsuda"
                            3 => "T&#46; Ogawa"
                            4 => "T&#46; Yakushiji"
                            5 => "T&#46; Miyasaka"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1111/j.1744-9987.2010.00869.x"
                      "Revista" => array:6 [
                        "tituloSerie" => "Ther Apher Dial"
                        "fecha" => "2011"
                        "volumen" => "15"
                        "paginaInicial" => "66"
                        "paginaFinal" => "74"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/21272255"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            12 => array:3 [
              "identificador" => "bib0190"
              "etiqueta" => "13"
              "referencia" => array:1 [
                0 => array:1 [
                  "referenciaCompleta" => "Kim JC&#44; Kim JH&#44; Kimg HC&#44; Kang E&#44; Kim KG&#44; Kim HC&#44; et al&#46; Effect of fiber structure on dialysate flow profile and hollow-fiber hemodialyzer reliability&#58; CT perfusion study&#46; Int J Art Organs&#46; 2088&#59;31&#58;944-950&#46;"
                ]
              ]
            ]
            13 => array:3 [
              "identificador" => "bib0195"
              "etiqueta" => "14"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "A model to predict optimal dialysate flow"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "A&#46; Alayoud"
                            1 => "M&#46; Benyahia"
                            2 => "D&#46; Montassir"
                            3 => "A&#46; Hamzi"
                            4 => "Y&#46; Zajjari"
                            5 => "A&#46; Bahadi"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1111/j.1744-9987.2011.01040.x"
                      "Revista" => array:7 [
                        "tituloSerie" => "Ther Apher Dial"
                        "fecha" => "2012"
                        "volumen" => "16"
                        "paginaInicial" => "152"
                        "paginaFinal" => "158"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22458394"
                            "web" => "Medline"
                          ]
                        ]
                        "itemHostRev" => array:3 [
                          "pii" => "S0090825898949733"
                          "estado" => "S300"
                          "issn" => "00908258"
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            14 => array:3 [
              "identificador" => "bib0200"
              "etiqueta" => "15"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Increasing dialysate flow rate increases dialyzer urea clearance and dialysis efficiency&#58; An in vivo study"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:1 [
                            0 => "A&#46; Azar"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Saudi J Kidney Dis Transplant"
                        "fecha" => "2009"
                        "volumen" => "20"
                        "paginaInicial" => "1023"
                        "paginaFinal" => "1029"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            15 => array:3 [
              "identificador" => "bib0205"
              "etiqueta" => "16"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Effect of increasing dialysate flow rate on diffusive mass transfer of urea&#44; phosphate and &#946;2-microglobulin during clinical haemodialysis"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "J&#46; Bhimani"
                            1 => "R&#46; Ouseph"
                            2 => "R&#46; Ward"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1093/ndt/gfq326"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nephrol Dial Transplant"
                        "fecha" => "2010"
                        "volumen" => "25"
                        "paginaInicial" => "3990"
                        "paginaFinal" => "3995"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/20543211"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            16 => array:3 [
              "identificador" => "bib0210"
              "etiqueta" => "17"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Effects of reduced dialysis fluid flow in hemodialysis"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "T&#46; Kahiwagi"
                            1 => "K&#46; Sato"
                            2 => "S&#46; Kawakami"
                            3 => "M&#46; Kiyomoto"
                            4 => "M&#46; Enomoto"
                            5 => "T&#46; Suzuki"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "J Nippon Med Sch"
                        "fecha" => "2013"
                        "volumen" => "80"
                        "paginaInicial" => "119"
                        "paginaFinal" => "130"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23657065"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            17 => array:3 [
              "identificador" => "bib0215"
              "etiqueta" => "18"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Dialysate flow rate and delivered KT&#47;V urea for dialyzers with enhanced dialysate flow distribution"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:6 [
                            0 => "R&#46;A&#46; Ward"
                            1 => "J&#46;W&#46; Idoux"
                            2 => "H&#46; Hamdan"
                            3 => "R&#46; Ouseph"
                            4 => "T&#46;A&#46; Depner"
                            5 => "T&#46;A&#46; Golper"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.2215/CJN.02630311"
                      "Revista" => array:6 [
                        "tituloSerie" => "Clin J Am Soc Nephrol"
                        "fecha" => "2011"
                        "volumen" => "6"
                        "paginaInicial" => "2235"
                        "paginaFinal" => "2239"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/21799145"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            18 => array:3 [
              "identificador" => "bib0220"
              "etiqueta" => "19"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Toward green dialysis&#58; Focus on water savings"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "L&#46; Ponson"
                            1 => "W&#46; Arkouche"
                            2 => "M&#46; Laville"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1111/hdi.12117"
                      "Revista" => array:7 [
                        "tituloSerie" => "Hemodial Int"
                        "fecha" => "2014"
                        "volumen" => "18"
                        "paginaInicial" => "7"
                        "paginaFinal" => "14"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/24319997"
                            "web" => "Medline"
                          ]
                        ]
                        "itemHostRev" => array:3 [
                          "pii" => "S0090825898953173"
                          "estado" => "S300"
                          "issn" => "00908258"
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            19 => array:3 [
              "identificador" => "bib0225"
              "etiqueta" => "20"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Dialysate saving by automated control of flow rates&#58; Comparison between individualized online hemodiafiltration and standard hemodialysis"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "E&#46; Mesic"
                            1 => "A&#46; Bock"
                            2 => "L&#46; Major"
                            3 => "L&#46; Vaslaki"
                            4 => "K&#46; Berta"
                            5 => "B&#46; Wikstrom"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1111/j.1542-4758.2011.00577.x"
                      "Revista" => array:6 [
                        "tituloSerie" => "Hemodial Int"
                        "fecha" => "2011"
                        "volumen" => "15"
                        "paginaInicial" => "522"
                        "paginaFinal" => "529"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22111821"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            20 => array:3 [
              "identificador" => "bib0230"
              "etiqueta" => "21"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "C&#225;lculo del Kt como indicador de calidad en el &#225;rea de adecuaci&#243;n en hemodi&#225;lisis"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "M&#46; Molina N&#250;&#241;ez"
                            1 => "S&#46; Roca Mero&#241;o"
                            2 => "R&#46;M&#46; de Alarc&#243;n"
                            3 => "M&#46;A&#46; Garc&#237;a"
                            4 => "C&#46; Jimeno"
                            5 => "G&#46;M&#46; &#193;lvarez"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.3265/Nefrologia.pre2010.Apr.10408"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nefrolog&#237;a"
                        "fecha" => "2010"
                        "volumen" => "30"
                        "paginaInicial" => "331"
                        "paginaFinal" => "336"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/20514099"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            21 => array:3 [
              "identificador" => "bib0235"
              "etiqueta" => "22"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Ten-year patient survival on maintenance haemodialysis&#58; Association with treatment time and dialysis dose"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "S&#46; Singh"
                            1 => "P&#46; Choi"
                            2 => "A&#46; Power"
                            3 => "D&#46; Ashby"
                            4 => "T&#46; Cairns"
                            5 => "M&#46; Griffith"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.5301/jn.5000234"
                      "Revista" => array:6 [
                        "tituloSerie" => "J Nephrol"
                        "fecha" => "2013"
                        "volumen" => "26"
                        "paginaInicial" => "763"
                        "paginaFinal" => "770"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23147685"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            22 => array:3 [
              "identificador" => "bib0240"
              "etiqueta" => "23"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Influence of the ionic dialysance monitor on Kt measurement in hemodialysis"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "F&#46; Maduell"
                            1 => "M&#46; Vera"
                            2 => "M&#46; Arias"
                            3 => "N&#46; Serra"
                            4 => "M&#46; Blasco"
                            5 => "E&#46; Bergad&#225;"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1053/j.ajkd.2008.03.014"
                      "Revista" => array:6 [
                        "tituloSerie" => "Am J Kid Dis"
                        "fecha" => "2008"
                        "volumen" => "52"
                        "paginaInicial" => "85"
                        "paginaFinal" => "92"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/18455852"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            23 => array:3 [
              "identificador" => "bib0245"
              "etiqueta" => "24"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "El sistema ultracontrol&#174; de HDF-OL posdilucional optimiza el volumen ultrafiltrado total por sesi&#243;n"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:6 [
                            0 => "R&#46; P&#233;rez-Garc&#237;a"
                            1 => "P&#46; de Sequera"
                            2 => "M&#46; Ortega"
                            3 => "M&#46; Puerta"
                            4 => "M&#46; Albalate"
                            5 => "R&#46; Alc&#225;zar"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.3265/NEFROLOGIA.2009.29.S.E.noID.36.free"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nefrolog&#237;a"
                        "fecha" => "2009"
                        "volumen" => "29"
                        "numero" => "Suppl 2"
                        "paginaInicial" => "63"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/20221231"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            24 => array:3 [
              "identificador" => "bib0250"
              "etiqueta" => "25"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Dialysis and ecology&#58; Can we do better in the future&#63;"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:4 [
                            0 => "Y&#46; Vuignier"
                            1 => "M&#46; Pruijm"
                            2 => "F&#46; Jarrayah"
                            3 => "M&#46; Burnier"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Rev Med Suisse"
                        "fecha" => "2013"
                        "volumen" => "9"
                        "paginaInicial" => "468"
                        "paginaFinal" => "472"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23539814"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
          ]
        ]
      ]
    ]
    "agradecimientos" => array:1 [
      0 => array:4 [
        "identificador" => "xack198752"
        "titulo" => "Agradecimientos"
        "texto" => "<p id="par0190" class="elsevierStylePara elsevierViewall">Este trabajo ha podido realizarse gracias a la colaboraci&#243;n del personal de enfermer&#237;a de la unidad de hemodi&#225;lisis&#46;</p>"
        "vista" => "all"
      ]
    ]
  ]
  "idiomaDefecto" => "es"
  "url" => "/02116995/0000003500000006/v1_201512190045/S0211699515001459/v1_201512190045/es/main.assets"
  "Apartado" => array:4 [
    "identificador" => "42448"
    "tipo" => "SECCION"
    "en" => array:2 [
      "titulo" => "Originales"
      "idiomaDefecto" => true
    ]
    "idiomaDefecto" => "en"
  ]
  "PDF" => "https://static.elsevier.es/multimedia/02116995/0000003500000006/v1_201512190045/S0211699515001459/v1_201512190045/es/main.pdf?idApp=UINPBA000064&text.app=https://revistanefrologia.com/"
  "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0211699515001459?idApp=UINPBA000064"
]
Compartir
Información de la revista
Vol. 35. Núm. 6.noviembre - diciembre 2015
Páginas 517-602
Visitas
18990
Vol. 35. Núm. 6.noviembre - diciembre 2015
Páginas 517-602
Original
Open Access
¿Cuál es el flujo de baño óptimo en la hemodiafiltración on-line posdilucional?
What is the optimum dialysate flow in post-dilution online haemodiafiltration?
Visitas
18990
Marta Albalate Ramón
Autor para correspondencia
malbalater@senefro.org

Autor para correspondencia.
, Patricia de Sequera Ortiz, Rafael Pérez-García, Elena Corchete Prats, Roberto Alcázar Arroyo, Mayra Ortega Díaz, Marta Puerta Carretero
Servicio de Nefrología, Hospital Infanta Leonor, Madrid, España
Este artículo ha recibido

Under a Creative Commons license
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Tablas (3)
Tabla 1. Resultados de la HDFOL con los diferentes Qd
Tabla 2. Resultados de la HDFOL-P con los diferentes monitores, en la columna de la derecha se señalan las diferencias significativas entre cada pares de grupos (prueba post-hoc)
Tabla 3. Líquido de diálisis consumido con los diferentes flujos de baño
Mostrar másMostrar menos
Resumen
Introducción

En la hemodiafiltración en línea posdilucional (HDFOL) la única recomendación acerca del líquido de diálisis (LD) hace referencia a su pureza. No se ha definido si usar flujos de baño (Qd) elevados tiene alguna utilidad para aumentar el Kt o el volumen de ultrafiltración-infusión (VI).

Objetivo

Estudiar cómo influye el Qd en el Kt y en el VI en la HDFOL.

Material y métodos

Estudio cruzado prospectivo. Se incluyó a 37 pacientes a los que se les realizaron 6 sesiones de HDFOL con cada Qd: 500, 600 y 700ml/min. Veintiún pacientes se dializaron en monitor 5008® y 17 con AK-200®. Los dializadores utilizados fueron: 20 con FX800® y 17 con Polyflux-210®. El resto de los parámetros se mantuvieron constantes. Se recogieron del monitor: flujo efectivo de sangre, tiempo efectivo de diálisis, Kt final y VI.

Resultados

Encontramos que usando un Qd=600 o 700ml/min, el Kt aumentó un 1,7% respecto al uso de Qd=500ml/min. Las diferencias de VI no fueron significativas.

Aumentar el Qd de 500ml/min a 600 y 700ml/min aumenta el consumo de LD un 20 y un 40%, respectivamente.

Conclusiones

En la HDFOL con los monitores y dializadores utilizados no son útiles los Qd superiores a 500ml/min para aumentar la eficacia del Kt ni el VI, por lo que su utilización implica un despilfarro de un recurso como el agua, tan importante tanto desde el punto de vista ecológico como económico.

Palabras clave:
Flujo de líquido de diálisis
Kt
Hemodiafiltración en línea
Flujo de infusión
Abstract
Introduction

In post-dilution online hemodiafiltration (OL-HDF), the only recommendation concerning the dialysate, or dialysis fluid, refers to its purity. No study has yet determined whether using a high dialysate flow (Qd) is useful for increasing Kt or ultrafiltration-infusion volume.

Objective

Study the influence of Qd on Kt and on infusion volume in OL-HDF.

Material and methods

This was a prospective crossover study. There were 37 patients to whom 6 sessions of OL-HDF were administered at 3 different Qds: 500, 600 and 700ml/min. A 5008® monitor was used for the dialysis in 21 patients, while an AK-200® was used in 17. The dialysers used were: 20 with FX 800® and 17 with Polyflux-210®. The rest of the parameters were kept constant. Monitor data collected were effective blood flow, effective dialysis time, final Kt and infused volume.

Results

We found that using a Qd of 600 or 700ml/min increased Kt by 1.7% compared to using a Qd of 500ml/min. Differences in infusion volume were not significant. Increasing Qd from 500ml/min to 600 and 700ml/min increased dialysate consumption by 20% and 40%, respectively.

Conclusions

With the monitors and dialysers currently used in OL-HDF, a Qd higher than 500ml/min is unhelpful for increasing the efficacy of Kt or infusion volume. Consequently, using a high Qd wastes water, a truly important resource both from the ecological and economic points of view.

Keywords:
Dialysate flow rate
Kt
Hemodiafiltration on-line
Infusion volume
Texto completo

La hemodiafiltración en línea posdilucional (HDFOL) es una técnica de tratamiento sustitutivo que tiene diversas ventajas respecto a la hemodiálisis (HD): mejoría de la estabilidad hemodinámica, de la respuesta a los agentes estimulantes de la eritropoyesis y a la hormona del crecimiento en niños en diálisis, mayor eliminación de fosfatos y β2-microglobulina, disminución de la incidencia de la amiloidosis relacionada con la diálisis y de los marcadores-mediadores de inflamación crónica, mejor preservación del estado nutricional y de la función renal residual (FRR), respuesta favorable de la encefalopatía hepática y, en estudios recientes, mejor supervivencia1. En ella se usa el propio líquido de diálisis (LD) (ultrapuro) como líquido de reposición y, aunque se considera que es coste-efectiva2, su uso en ocasiones se ha limitado por la necesidad de utilizar grandes volúmenes de LD.

En HD para controlar la dosis de diálisis administrada se utilizan el Kt/V o el Kt basados en unos niveles mínimos por debajo de los cuales aumenta la mortalidad. Las guías clínicas recomiendan un Kt/V mínimo de 1,2 o un ratio de reducción de urea del 65%, pero los diferentes monitores de HD han incorporado biosensores que miden de forma no invasiva la dialisancia iónica efectiva que es equivalente al aclaramiento de urea (K). Estos sensores permiten calcular la dosis de diálisis sin carga de trabajo, sin determinaciones analíticas ni coste adicional, evitando los sesgos que conlleva la inclusión del término V (volumen de distribución de urea) y dando una medida real de la dosis de diálisis recibida en cada sesión. En 1999, Lowrie et al. propusieron el Kt como marcador de dosis de diálisis y mortalidad, recomendando un Kt mínimo de 40-45 L para las mujeres y 45-50 para los hombres3. En un estudio de 3.009 pacientes, observaron que un mayor Kt se acompañaba de una mayor supervivencia e individualizaron la prescripción del Kt ajustándola al área de superficie corporal (SC), en una medida tremendamente exigente4. Aunque está por aclarar si las dosis de diálisis son las mismas en HDFOL, mientras no contemos con otras evidencias, los pacientes en HDFOL deberían tener los mismos objetivos que los de HD. Además, distintos estudios han mostrado que la cantidad de volumen convectivo administrado parece ser decisivo en la mejora de supervivencia, que fue de 15 l/sesión en el European Dialysis Outcomes and Practice Pattern Study (DOPPS)5, 17,4 l/sesión en el estudio turco6, 21,9 L en el Convective Transport Study (CONTRAST)7 y de 23,1 L en el Estudio de Supervivencia de Hemodiafiltración On-Line (ESHOL)8. Estos estudios ponen en evidencia la necesidad de alcanzar volúmenes convectivos altos para reducir la mortalidad y, por ello, nosotros, siguiendo los estándares de calidad más exigentes, nos marcamos como objetivo conseguir volúmenes superiores a 24 L.

La dosis de diálisis (o Kt) depende del KoA del dializador, de las condiciones de flujo (sangre [Qb], líquido de diálisis [Qd] y ultrafiltración) y del tiempo de diálisis. Estudios realizados en los años 90 encontraron que el KoA y el aclaramiento podrían aumentar al incrementar el Qd9,10. Los resultados de estos estudios en HD llevaron a aumentar el Qd a 700-800ml/min para mejorar el aclaramiento. Pero en los últimos años los cambios en el diseño de los dializadores (fibras cruzadas con un cierto ángulo u onduladas, con diferente densidad de empaquetado y distribuidores del flujo en la entrada del baño) han mejorado sus prestaciones11–13. De este modo, trabajos más recientes han mostrado que con estos dializadores, aumentar el Qd no modifica prácticamente la eficacia de la HD14–18. Pero, ¿qué ocurre en HDFOL? Nosotros no hemos encontrado ningún trabajo que estudie el efecto que tiene utilizar distintos Qd, ni que mencione qué Qd es más adecuado en HDFOL valorando sus efectos sobre el Kt o el VI. Usar un Qd elevado supone un mayor consumo de agua y de concentrados, de modo que esta medida solo debería usarse si se consigue mejorar el resultado de las diálisis en cuanto a Kt o VI. El cuidado de los recursos naturales es vital para la sociedad y en los últimos años se ha tomado plenamente conciencia de la verdadera necesidad de cuidar el agua. En muchos lugares del mundo el agua es un bien escaso y, aunque en las unidades de HD se debería cuidar su consumo, en la mayoría se desperdician grandes volúmenes19. Para mejorar, se han propuesto varias soluciones como reciclar el agua rechazada, aunque una medida inicial y básica es no utilizar el agua de forma innecesaria. Saber qué Qd es el óptimo en HDFOL pasa a convertirse en un objetivo básico para lograr un consumo más racional de agua.En el presente estudio nos planteamos estudiar el efecto que tiene el Qd sobre el Kt y el VI en HDFOL.

Objetivos

  • 1.

    Estudiar la influencia del Qd (500, 600 y 700ml/min) en el Kt y VI en HDFOL.

  • 2.

    Cuantificar el ahorro de agua que conlleva.

Material y métodos

Se trata de un estudio prospectivo realizado en un único centro de diálisis, con un diseño cruzado. Los sujetos incluidos debían ser mayores de 18 años y llevar en HDFOL más de 3 meses.

Los datos demográficos recogidos fueron: sexo, edad, tiempo en HD y etiología de la enfermedad renal. Se calculó el Kt objetivo (Ktobj) individual ajustado a la SC.

Se incluyó a 37 pacientes (16 mujeres y 21 hombres). Los monitores y dializadores fueron idénticos a lo largo de todo el estudio. Un total de 16 pacientes fueron dializados con AK 200® y 21 con Fresenius 5008®. Las membranas utilizadas fueron distribuidas de la siguiente manera: 20 FX800® y 17 Polyflux 210H®.Todos los pacientes fueron dializados en HDFOL tal y como sigue:

  • -

    6 sesiones con Qd a 500ml/min.

  • -

    6 sesiones con Qd a 600ml/min.

  • -

    6 sesiones con Qd a 700ml/min.

Se mantuvieron durante todo el periodo: el tiempo de diálisis, la anticoagulación y el flujo de sangre. Los volúmenes de ultrafiltración fueron ajustados de acuerdo con las necesidades clínicas. Cuando el sistema 5008® mide la recirculación, el Qd se incrementa temporalmente a 800ml/min. Nuestro trabajo rutinario mide la recirculación una vez en la sesión.

Se recogieron directamente desde la pantalla del monitor los siguientes parámetros: flujo de sangre efectivo (Qbe), el Qd, el tiempo efectivo de diálisis, Kt final (Ktf) y VI final.

A partir de los datos recogidos, se calcularon:

  • 1.

    Los valores medios individuales de Qbe, tiempo efectivo de diálisis, VI y Ktf con cada Qd.

  • 2.

    Diferencias de Kt: Ktobj-Ktf.

  • 3.

    Diferencias de VI (objetivo = 24 l): VIobj-VI final.

Estadística

Las variables cualitativas se muestran con porcentajes y las variables cuantitativas como medias (desviación estándar) o medianas (mínimo-máximo). Los estudios de t-pareada y Anova fueron utilizados para comparar variables cuantitativas. Los test chi-cuadrado fueron utilizados para las variables cualitativas. Un valor de p menor de 0,05 fue considerado como estadísticamente significativo.Los análisis fueron realizados con el programa informático SPSS versión 15.0.

Resultados

Los 37 pacientes incluidos tenían una mediana de edad de 67,4 años (36-92). La etiología de la ERC era: 13 diabetes mellitus, 7 glomerular, 6 desconocida, 5 vascular, 4 intersticial y 2 poliquísticos. Un total de 36 se dializaban 3 veces a la semana y un paciente 2 veces a la semana por tener buena función renal residual, que definimos como un aclaramiento medio de urea y creatinina en orina de 24 h superior a 5ml/min. La duración de la diálisis programada fue 240min en 7 pacientes, 255min en 25 pacientes, 270min en 4 pacientes y 300min para un paciente. Treinta pacientes se dializaban con fístula y el resto con catéter tunelizado.

Recogimos 565 sesiones: 192 con 500ml/min, 194 con 600ml/min y 179 con 700ml/min. Se excluyeron las sesiones en las que existía desviación en el tiempo de tratamiento prescrito, en el Qb o en las que por problemas técnicos no se había medido K. Todos los pacientes se hicieron al menos 3 sesiones con cada Qd.

Eficacia de la diálisis

La tabla 1 muestra los resultados obtenidos respecto al Kt y VI: Kt ligeramente más alto si el Qd era más elevado y lo contrario con el VI. El Kt se incrementó un 1,7% (500 frente a 600 o 700ml/min). No se encontraron diferencias en el Qbe entre los diferentes Qd utilizados, aunque el tiempo efectivo era un minuto inferior con un Qd de 700ml/min.

Tabla 1.

Resultados de la HDFOL con los diferentes Qd

Qd  500ml/min (a)M (DE)  600ml/min (b)M (DE)  700ml/min (c)M (DE)  p post-hoc 
Tiempo efectivo (min)  246,7(9,6)  246,3 (10,0)  245,0 (10,0)  <0,010 a,cb,c 
Qb efectivo (ml/min)  390,0 (33,6)  388,8 (34,7)  387,9 (37,0)  NS 
Kt (L)  61,4 (5,9)  62,5 (6,5)  62,9 (7,2)  <0,005 a,c 
DifKtobj (L)  12,4 (6,0)  13,4 (6,4)  13,3 (8,0)  NS 
VI (L)  27,7 (3,1)  27,7 (3,2)  27,1 (3,4)  <0,009 a,c<0,010 b,c 

DifKtobj: diferencia entre el Kt objetivo y Kt final con los diferentes Qd, Abreviaturas: M: media, DE: desviación estándar a: 500ml/min, b: 600ml/min y c: 700ml/min. En la columna de la derecha se señalan las diferencias significativas entre cada pares de grupos (prueba post-hoc).

En el estudio de la adecuación individual, el Ktobj medio era 49 (4,2) L (36-56,7 L). En la tabla 1 aparece la diferencia entre el Kt alcanzado y el objetivo, con un Kt alcanzado muy por encima del Ktobj ajustado a SC con todos los Qd. Solo un paciente no alcanzó el Ktobj por problemas con su acceso vascular y no logró alcanzarlo con ninguno de los Qd empleados.

No se alcanzaron los 24 L en: 2 pacientes con 500ml/min (VI medio: 23,7 L), 2 pacientes con 600ml/min (VI medio: 23,8 L) y en 5 pacientes con 700ml/min (VI 23,2 L). Solo un paciente tuvo un VI medio «bajo» (20 L). Se trata de un paciente con una amputación bilateral supracondílea, que se dializa por un catéter tunelizado con problemas para lograr Qb superiores a 350ml/min. No existieron diferencias estadísticamente significativas entre los que no y sí alcanzaban VI con Qd=700ml/min (el grupo más numeroso) ni en Kt ni tiempo efectivo, aunque el Qbe tendía a ser inferior 376,5 (39,3) vs. 393 (35,2) ml/min. Todos se dializaban en un monitor 5008®.

Diferencias según monitor

Separamos el resultado por monitores basándonos en los diferentes métodos utilizados para controlar el volumen convectivo y los resultados pueden verse en la tabla 2. Con ambos monitores la tendencia es a un Kt más elevado con Qd más elevado. En cambio, en el VI, mientras con el monitor Fresenius® el VI es similar con cualquier Qd, en el monitor Gambro® el VI era ligeramente inferior si se usaba un Qd más alto.

Tabla 2.

Resultados de la HDFOL-P con los diferentes monitores, en la columna de la derecha se señalan las diferencias significativas entre cada pares de grupos (prueba post-hoc)

Qd500ml/min (a)M (DE)  600ml/min (b)M (DE)  700ml/min (c)M (DE)  p post-hoc 
Kt (L)AK200  59,8 (6,6)  60,8 (7,0)  61,1 (7,5)  <0,008 a,b<0,020 a,c 
5008  62,7 (5,1)  63,8 (5,9)  64,1 (7,0)  <0,020 a,b 
VI (L)AK200  28,9 (3,1)  29,0 (3,3)  28,0 (3,3)  <0,040 a,c<0,040 b,c 
5008  26,9 (3,0)  26,8 (2,8)  26,6 (3,7)  NS 
Consumo de líquido de diálisis

El consumo calculado de ácido y LD en una sesión de 255 min aparece en la tabla 3. Así con 600ml/min se necesita un 20% y con 700ml/min un 40% más de LD que con 500ml/min.

Tabla 3.

Líquido de diálisis consumido con los diferentes flujos de baño

Qd  LD consumido (l) sesión  Ácido consumido (l)/sesión  Exceso anual LD/pac (l)  Exceso anual con 75 pac (l)  Euros ahorrados Gambro 75 pac/año  Euros ahorrados Fresenius 75 pac/año 
500 ml/min  127,5  2,8       
600 ml/min  153  3,4  4.056  304.200  9.126  6.084 
700 ml/min  178,5  3,9  7.956  596.700  17.901  11.934 

El exceso anual/pac: consumo teórico de agua al usar 600 o 700 vs. 500ml/min en litros.

En la tabla 3 hemos reflejado el exceso de consumo que supone usar 600 o 700 vs. 500ml/min, no solo por paciente sino en el total de una unidad como la nuestra con 75 enfermos. Es importante resaltar que este consumo hace referencia al LD, no al consumo global de agua, que sería cerca del doble, ya que para formar un litro de LD ultrapuro se precisa desechar entre 0,5 y 1 L de agua en el proceso de tratamiento.

Hemos realizado un cálculo parcial del coste de un litro de LD (agua+ácido) para poder calcular el ahorro económico que supondría. Así un litro de LD cuesta 0,03 euros en el monitor Fresenius y 0,02 en Gambro, a coste local. En la tabla 3 se incluye el ahorro económico que supone por paciente/año disminuir el Qd.

Discusión

El principal resultado de nuestro trabajo es que aumentar el Qd en HDFOL logra una pequeña mejoría en el Kt y no tiene influencia práctica en el VI. Aunque el resultado pueda ser estadísticamente significativo, la relevancia clínica de estas diferencias es más que cuestionable, máxime si se tiene en cuenta el consumo de agua necesario para lograrlo.

La información existente sobre la utilidad de usar un Qd determinado en HDFOL es prácticamente nula. En la mayoría de las unidades se utiliza un Qd de 700ml/min con la idea de aumentar la eficacia del transporte difusivo, pero la base de este uso no está fundamentada. De hecho, solo hemos encontrado un trabajo acerca del efecto del Qd en la HDFOL. Este trabajo compara HD con HDFOL utilizando autoflujo (AF), sistema que incorporan los monitores 5008® en los que el Qd se ajusta al Qb. Los autores concluyen que con la HDFOL se puede obtener un mejor Kt/V usando menos LD que en HD20. Pero no hemos encontrado publicaciones en las que se compare el efecto que tienen distintos Qd sobre la eficacia o el VI en HDFOL, lo que da a nuestro trabajo un carácter novedoso y eminente práctico. Nuestros resultados muestran que, al igual que ocurre en la HD, aumentar el Qd tiene un mínimo efecto sobre la eficacia de la HD, dato que es mucho más relevante si se tiene en cuenta que no está basado en el Kt/V calculado con las concentraciones de urea pre- y posdiálisis o el V introducido en el monitor. Nuestra medida de adecuación se basa en el Kt ajustado a SC, que es una forma tremendamente exigente21. Con ello, solo en un paciente con problemas de FAV no se logró el objetivo con ninguno de los Qd utilizados, por lo que no parece que aumentar el Qd sea una medida útil para mejorarlo. Este resultado aboga por no utilizar Qd elevados en la HDFOL con el objetivo de aumentar la eficacia como clásicamente se ha indicado, máxime teniendo en cuenta que la disminución de la mortalidad con esta técnica se relaciona con la cantidad de volumen convectivo administrado. Se podría alegar que con el Qb = 700ml/min el tiempo efectivo era menor y que al igualar esa diferencia de tiempo se lograría aumentar más Kt. Dado que todos sabemos que prolongar el tiempo se asocia a una mejor supervivencia independientemente de la dosis de diálisis22, habría que poner en la balanza el efecto de pérdida de tiempo, posiblemente por controles internos de la máquina vs. mejoría del Kt y, dado que ambas diferencias son mínimas y posiblemente poco relevantes, creemos que usar un Qd superior a 500ml/min no es una medida eficaz.

En cuanto al VI, como era lógico, el Qd prácticamente no tiene influencia. Hoy en día las técnicas automáticas de HDFOL intentan conseguir un mayor rendimiento de transporte convectivo, pero cada monitor tiene diferentes sistemas de control y obtiene resultados diferentes. De hecho «regulan» el VI basándose en métodos que los nefrólogos no siempre conocemos. En cualquier caso, parece claro que usar Qd elevados no tiene repercusión ni utilidad para modificar el VI en la HDFOL. Cuando estudiamos si se logran los objetivos, solo un enfermo quedaba lejos de lograr los 24 l fijados (obteniendo en torno a 20 l) por un problema de Qb al dializarse por un CT. Es interesante tener en cuenta que este paciente tenía una amputación supracondílea bilateral. En el momento actual no contamos con ninguna forma de hacer una prescripción individualizada de VI, como ocurre con el Kt, de acuerdo con la SC. Este hecho nos sirve para reflexionar sobre la necesidad de conocer cuál es el objetivo de VI para cada paciente y desarrollar así una HDFOL plenamente individualizada. Para el resto de los que no lo lograban, aunque estaban cerca, el hecho no dependía tampoco del Qd utilizado. Eran pacientes con un VI muy ajustado a 24 l y quienes, posiblemente aumentando el Qb o el tiempo o revisando si se puede conseguir mejor rendimiento con otro método, lo alcanzarían independientemente del Qd. Finalmente cabe recordar que muchos trabajos incluyen en el volumen convectivo el VI más el volumen de ultrafiltración pautado para lograr el peso seco. Nosotros no hemos sumado el volumen de ultrafiltración, con lo que habríamos alcanzado el objetivo de los 24 l.

No comparamos el Kt ni VI que se obtenía con diferentes monitores, ya que no era el objetivo de nuestro estudio ni estaba diseñado para ello. Creemos que las diferencias observadas en la tabla 2 en cuanto al Kt están de acuerdo con los resultados del trabajo publicado por Maduell et al. que ya mostraba que la dialisancia iónica calculada por los monitores Fresenius era más elevada que la calculada por monitor AK200®23. Igualmente, el mayor VI que logra el método Ultracontrol® está de acuerdo con nuestros resultados previos24.

El agua potable, empleada para consumo humano, no sirve para la fabricación de LD: es imprescindible purificarla. Para la HDFOL el aspecto del agua en el que se hace hincapié es en la obligatoriedad de utilizar un agua y LD ultrapuros, haciendo mención a su calidad pero no a su cantidad. Tratar a un paciente durante varias horas 3 veces por semana requiere grandes cantidades de energía y agua, además de que genera productos médicos desechables. Se calcula que el balance ambiental promedio de una sesión de HD es de aproximadamente 400-500 l de agua, 10 kw/hora de electricidad y hasta 3 kg de desechos clínicos25. Por lo tanto, en lo que respecta al LD, fabricar LD ultrapuro conlleva problemas económicos y ecológicos. Aunque nosotros hemos mostrado el LD directamente utilizado, queremos insistir en que para producir ese litro, otro litro se ha perdido en el proceso de tratamiento; es decir, para generar un litro de LD en ósmosis inversa se necesitan 2 l de agua, lo que supone el doble de consumo. El agua es un elemento clave para la subsistencia de la vida, y su manejo es hoy absolutamente necesario desde la perspectiva del buen uso de los recursos naturales: es necesario aumentar la conciencia sobre temas ambientales entre el personal de la clínica de diálisis. Si pensamos en una sesión de 255min, bajar de 700 a 500ml/min y ahorrar 51 l de LD en cada paciente puede parecer poco relevante, pero implica en una unidad de 75 pacientes más de 500.000 l de LD en un año o, como hemos explicado, 1.000.000 l de agua potable, además del ahorro de ácido, con la consiguiente ventaja económica y ecológica. A este beneficio ecológico hay que sumar el económico. Hemos realizado una valoración del coste de un litro de LD teniendo en cuenta el agua más el ácido. No se ha sumado el bicarbonato, ya que asumimos que utilizamos un cartucho por sesión con cualquier Qd, para facilitar el cálculo, aunque en ocasiones es necesario pasar a usar un cartucho con mayor cantidad de bicarbonato y, por tanto mayor precio, al aumentar el Qd. Aunque a simple vista el precio de un litro parece desdeñable, se pone de relieve la importancia si tenemos en cuenta el consumo sobre una n: anual. Además, nuestros cálculos no han tenido en cuenta el agua consumida durante la preparación ni la desinfección (por lo que el ahorro podría ser mayor si se optimizasen esos consumos), ni otros gastos de mantenimiento de la planta de tratamiento de agua, que parcialmente se pueden ver afectados por un mayor consumo de agua.

La principal limitación de nuestro estudio es que el número de pacientes incluido es pequeño, pero el número de sesiones de diálisis es suficiente y el diseño cruzado permite comparar cada paciente consigo mismo, lo que refuerza los resultados. También nuestro estudio ha sido realizado en una única unidad de diálisis pero pensamos que nuestros resultados pueden ser extrapolados a todas las unidades que trabajan en condiciones similares.

Conclusiones

Nuestros datos indican que aumentar el Qd por encima de 500ml/min en HDFOL ofrece un beneficio limitado. Mejorar la eficacia de diálisis ahorrando agua es importante para el medio ambiente y para satisfacer la demanda humana actual y futura, logrando así una diálisis mucho más eficiente. Si utilizar Qd inferiores es factible es el terreno que queda por estudiar.

Conflicto de intereses

El Dr. Pérez García, la Dra. de Sequera y la Dra. M. Albalate han participado en reuniones de Fresenius y Gambro.

Agradecimientos

Este trabajo ha podido realizarse gracias a la colaboración del personal de enfermería de la unidad de hemodiálisis.

Bibliografía
[1]
R. Pérez-García.
On-line haemodiafiltration after the ESHOL study.
[2]
T. Takura, H. Kawanishi, J. Minakuchi, Y. Nagake, S. Takahashi.
Cost-effectiveness analysis of on-line hemodiafiltration in Japan.
Blood Purif, 35 (2013), pp. 85-89
[3]
E.G. Lowrie, G.M. Chertow, N.L. Lew, J.M. Lazarus, W.F. Owen.
The urea {clearance x dialysis time} product (KT) as an outcome-based measure of hemodialysis dose.
Kidney Int, 56 (1999), pp. 729-737
[4]
E.G. Lowrie, Z. Li, N.J. Ofsthun.
Evaluating a new method to judge dialysis treatment using online measurements of ionic clearance.
Kidney Int, 70 (2006), pp. 211-217
[5]
B. Canaud, J.L. Bragg-Gresham, M.R. Marshall, S. Desmeules, B.W. Gillespie, T. Depner, et al.
Mortality risk for patients receiving hemodiafiltration versus hemodialysis: European results from the DOPPS.
Kidney Int, 69 (2006), pp. 2087-2093
[6]
E. Ok, G. Asci, E. Sevinc-Ok, F. Kircelli, M. Yilmaz, E. Hur, et al.
Comparison of posdilution on-line hemodiafiltration and hemodialysis (Turkish HDF Study).
Nephrol Dial Transplant, 28 (2013), pp. 192-202
[7]
M.P. Grooteman, M.A. van den Dorpel, M.L. Bots, E.L. Penne, N.C. van der Weerd, A.H. Mazairac, et al.
CONTRAST Investigators: Effect of on-line hemodiafiltration on all-cause mortality and cardiovascular outcomes.
J Am Soc Nephrol, 23 (2012), pp. 1087-1096
[8]
F. Maduell, F. Moreso, M. Pons, R. Ramos, J. Mora-Macià, J. Carreras, et al.
ESHOL Study Group, High-efficiency posdilution online hemodiafiltration reduces all-cause mortality in hemodialysis patients.
J Am Soc Nephrol, 24 (2013), pp. 487-497
[9]
J.K. Leypoldt, A.K. Cheung, L.Y. Agodoa, J.T. Daugirdas, T. Greene, P.R. Keshaviah.
Hemodialyzer mass transfer-area coefficients for urea increase at high dialysate flow rates.
Kidney Int, 51 (1997), pp. 2013-2017
[10]
R. Ouseph, R.A. Ward.
Increasing dialysate flow rate increases dialyzer urea mass transfer-area coefficients during clinical use.
Am J Kidney Dis, 37 (2001), pp. 316-320
[11]
A. Hirano, S. Kida, K. Yamamoto, K. Sakai.
Experimental evaluation of flow and dialysis performance of hollow-fiber dialyzers with different packing densities.
J Int Organs, 15 (2012), pp. 168-175
[12]
A. Hirano, K. Yamamoto, M. Matsuda, T. Ogawa, T. Yakushiji, T. Miyasaka, et al.
Evaluation of dialyzer jacket structure and hollow-fiber dialysis membranes to achieve high dialysis performance.
Ther Apher Dial, 15 (2011), pp. 66-74
[13]
Kim JC, Kim JH, Kimg HC, Kang E, Kim KG, Kim HC, et al. Effect of fiber structure on dialysate flow profile and hollow-fiber hemodialyzer reliability: CT perfusion study. Int J Art Organs. 2088;31:944-950.
[14]
A. Alayoud, M. Benyahia, D. Montassir, A. Hamzi, Y. Zajjari, A. Bahadi, et al.
A model to predict optimal dialysate flow.
Ther Apher Dial, 16 (2012), pp. 152-158
[15]
A. Azar.
Increasing dialysate flow rate increases dialyzer urea clearance and dialysis efficiency: An in vivo study.
Saudi J Kidney Dis Transplant, 20 (2009), pp. 1023-1029
[16]
J. Bhimani, R. Ouseph, R. Ward.
Effect of increasing dialysate flow rate on diffusive mass transfer of urea, phosphate and β2-microglobulin during clinical haemodialysis.
Nephrol Dial Transplant, 25 (2010), pp. 3990-3995
[17]
T. Kahiwagi, K. Sato, S. Kawakami, M. Kiyomoto, M. Enomoto, T. Suzuki, et al.
Effects of reduced dialysis fluid flow in hemodialysis.
J Nippon Med Sch, 80 (2013), pp. 119-130
[18]
R.A. Ward, J.W. Idoux, H. Hamdan, R. Ouseph, T.A. Depner, T.A. Golper.
Dialysate flow rate and delivered KT/V urea for dialyzers with enhanced dialysate flow distribution.
Clin J Am Soc Nephrol, 6 (2011), pp. 2235-2239
[19]
L. Ponson, W. Arkouche, M. Laville.
Toward green dialysis: Focus on water savings.
Hemodial Int, 18 (2014), pp. 7-14
[20]
E. Mesic, A. Bock, L. Major, L. Vaslaki, K. Berta, B. Wikstrom, et al.
Dialysate saving by automated control of flow rates: Comparison between individualized online hemodiafiltration and standard hemodialysis.
Hemodial Int, 15 (2011), pp. 522-529
[21]
M. Molina Núñez, S. Roca Meroño, R.M. de Alarcón, M.A. García, C. Jimeno, G.M. Álvarez, et al.
Cálculo del Kt como indicador de calidad en el área de adecuación en hemodiálisis.
[22]
S. Singh, P. Choi, A. Power, D. Ashby, T. Cairns, M. Griffith, et al.
Ten-year patient survival on maintenance haemodialysis: Association with treatment time and dialysis dose.
J Nephrol, 26 (2013), pp. 763-770
[23]
F. Maduell, M. Vera, M. Arias, N. Serra, M. Blasco, E. Bergadá, et al.
Influence of the ionic dialysance monitor on Kt measurement in hemodialysis.
Am J Kid Dis, 52 (2008), pp. 85-92
[24]
R. Pérez-García, P. de Sequera, M. Ortega, M. Puerta, M. Albalate, R. Alcázar.
El sistema ultracontrol® de HDF-OL posdilucional optimiza el volumen ultrafiltrado total por sesión.
[25]
Y. Vuignier, M. Pruijm, F. Jarrayah, M. Burnier.
Dialysis and ecology: Can we do better in the future?.
Rev Med Suisse, 9 (2013), pp. 468-472
Copyright © 2015. Sociedad Española de Nefrología
Descargar PDF
Idiomas
Nefrología
Opciones de artículo
Herramientas
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?