se ha leído el artículo
array:25 [ "pii" => "S0211699517300711" "issn" => "02116995" "doi" => "10.1016/j.nefro.2017.03.013" "estado" => "S300" "fechaPublicacion" => "2018-01-01" "aid" => "365" "copyright" => "Sociedad Española de Nefrología" "copyrightAnyo" => "2017" "documento" => "article" "crossmark" => 0 "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/" "subdocumento" => "fla" "cita" => "Nefrologia. 2018;38:34-40" "abierto" => array:3 [ "ES" => true "ES2" => true "LATM" => true ] "gratuito" => true "lecturas" => array:2 [ "total" => 4663 "formatos" => array:3 [ "EPUB" => 260 "HTML" => 3592 "PDF" => 811 ] ] "Traduccion" => array:1 [ "en" => array:20 [ "pii" => "S2013251417301992" "issn" => "20132514" "doi" => "10.1016/j.nefroe.2017.11.015" "estado" => "S300" "fechaPublicacion" => "2018-01-01" "aid" => "365" "copyright" => "Sociedad Española de Nefrología" "documento" => "article" "crossmark" => 0 "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/" "subdocumento" => "fla" "cita" => "Nefrologia (English Version). 2018;38:34-40" "abierto" => array:3 [ "ES" => true "ES2" => true "LATM" => true ] "gratuito" => true "lecturas" => array:2 [ "total" => 4239 "formatos" => array:3 [ "EPUB" => 316 "HTML" => 3274 "PDF" => 649 ] ] "en" => array:13 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Original article</span>" "titulo" => "Evaluation of the dialyzer inner diameter in online haemodiafiltration" "tienePdf" => "en" "tieneTextoCompleto" => "en" "tieneResumen" => array:2 [ 0 => "en" 1 => "es" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "34" "paginaFinal" => "40" ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Valoración del diámetro interno del dializador en hemodiafiltración <span class="elsevierStyleItalic">on-line</span>" ] ] "contieneResumen" => array:2 [ "en" => true "es" => true ] "contieneTextoCompleto" => array:1 [ "en" => true ] "contienePdf" => array:1 [ "en" => true ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0010" "etiqueta" => "Fig. 2" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr2.jpeg" "Alto" => 1310 "Ancho" => 1625 "Tamanyo" => 79063 ] ] "descripcion" => array:1 [ "en" => "<p id="spar0050" class="elsevierStyleSimplePara elsevierViewall">Variations in the dose of dialysis, measured by ionic dialysance, expressed as liters of Kt in the different study situations (<span class="elsevierStyleItalic">n</span><span class="elsevierStyleHsp" style=""></span>=<span class="elsevierStyleHsp" style=""></span>16) ANOVA for repeated measurements.</p>" ] ] ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "Francisco Maduell, Raquel Ojeda, Lara Belmar, Paula Munguía, Cristina Sango, Ana Isabel Martinez-Díaz, Marta Arias-Guillén, Manel Vera, Néstor Fontseré, Miquel Gómez, Lida Rodas, Nayra Rico" "autores" => array:12 [ 0 => array:2 [ "nombre" => "Francisco" "apellidos" => "Maduell" ] 1 => array:2 [ "nombre" => "Raquel" "apellidos" => "Ojeda" ] 2 => array:2 [ "nombre" => "Lara" "apellidos" => "Belmar" ] 3 => array:2 [ "nombre" => "Paula" "apellidos" => "Munguía" ] 4 => array:2 [ "nombre" => "Cristina" "apellidos" => "Sango" ] 5 => array:2 [ "nombre" => "Ana Isabel" "apellidos" => "Martinez-Díaz" ] 6 => array:2 [ "nombre" => "Marta" "apellidos" => "Arias-Guillén" ] 7 => array:2 [ "nombre" => "Manel" "apellidos" => "Vera" ] 8 => array:2 [ "nombre" => "Néstor" "apellidos" => "Fontseré" ] 9 => array:2 [ "nombre" => "Miquel" "apellidos" => "Gómez" ] 10 => array:2 [ "nombre" => "Lida" "apellidos" => "Rodas" ] 11 => array:2 [ "nombre" => "Nayra" "apellidos" => "Rico" ] ] ] ] ] "idiomaDefecto" => "en" "Traduccion" => array:1 [ "es" => array:9 [ "pii" => "S0211699517300711" "doi" => "10.1016/j.nefro.2017.03.013" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => true "ES2" => true "LATM" => true ] "gratuito" => true "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0211699517300711?idApp=UINPBA000064" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2013251417301992?idApp=UINPBA000064" "url" => "/20132514/0000003800000001/v1_201802180616/S2013251417301992/v1_201802180616/en/main.assets" ] ] "itemSiguiente" => array:20 [ "pii" => "S0211699517301315" "issn" => "02116995" "doi" => "10.1016/j.nefro.2017.05.008" "estado" => "S300" "fechaPublicacion" => "2018-01-01" "aid" => "396" "copyright" => "Sociedad Española de Nefrología" "documento" => "article" "crossmark" => 0 "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/" "subdocumento" => "fla" "cita" => "Nefrologia. 2018;38:41-7" "abierto" => array:3 [ "ES" => true "ES2" => true "LATM" => true ] "gratuito" => true "lecturas" => array:2 [ "total" => 18477 "formatos" => array:3 [ "EPUB" => 385 "HTML" => 17143 "PDF" => 949 ] ] "es" => array:13 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Original</span>" "titulo" => "La corrección del déficit de 25-OH-vitamina D mejora el control del hiperparatiroidismo secundario y el estado inflamatorio de pacientes estables en hemodiálisis" "tienePdf" => "es" "tieneTextoCompleto" => "es" "tieneResumen" => array:2 [ 0 => "es" 1 => "en" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "41" "paginaFinal" => "47" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Correction of 25-OH-vitamin D deficiency improves control of secondary hyperparathyroidism and reduces the inflammation in stable haemodialysis patients" ] ] "contieneResumen" => array:2 [ "es" => true "en" => true ] "contieneTextoCompleto" => array:1 [ "es" => true ] "contienePdf" => array:1 [ "es" => true ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0020" "etiqueta" => "Figura 4" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr4.jpeg" "Alto" => 1362 "Ancho" => 2669 "Tamanyo" => 136512 ] ] "descripcion" => array:1 [ "es" => "<p id="spar0070" class="elsevierStyleSimplePara elsevierViewall">Determinación del estado de microinflamación de los pacientes, antes y después de recibir el tratamiento, dado por el porcentaje de monocitos activados (CD14+/CD16+) antes y después del tratamiento (A), y por los niveles de proteína C reactiva (PCR) (B).</p>" ] ] ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "Raquel Ojeda López, Elvira Esquivias de Motta, Andrés Carmona, Victoria García Montemayor, Isabel Berdud, Alejandro Martín Malo, Pedro Aljama García" "autores" => array:7 [ 0 => array:2 [ "nombre" => "Raquel" "apellidos" => "Ojeda López" ] 1 => array:2 [ "nombre" => "Elvira" "apellidos" => "Esquivias de Motta" ] 2 => array:2 [ "nombre" => "Andrés" "apellidos" => "Carmona" ] 3 => array:2 [ "nombre" => "Victoria" "apellidos" => "García Montemayor" ] 4 => array:2 [ "nombre" => "Isabel" "apellidos" => "Berdud" ] 5 => array:2 [ "nombre" => "Alejandro" "apellidos" => "Martín Malo" ] 6 => array:2 [ "nombre" => "Pedro" "apellidos" => "Aljama García" ] ] ] ] ] "idiomaDefecto" => "es" "Traduccion" => array:1 [ "en" => array:9 [ "pii" => "S2013251418300026" "doi" => "10.1016/j.nefroe.2018.01.002" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => true "ES2" => true "LATM" => true ] "gratuito" => true "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "en" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2013251418300026?idApp=UINPBA000064" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0211699517301315?idApp=UINPBA000064" "url" => "/02116995/0000003800000001/v1_201801090621/S0211699517301315/v1_201801090621/es/main.assets" ] "itemAnterior" => array:20 [ "pii" => "S0211699517301030" "issn" => "02116995" "doi" => "10.1016/j.nefro.2017.04.002" "estado" => "S300" "fechaPublicacion" => "2018-01-01" "aid" => "383" "copyright" => "Sociedad Española de Nefrología" "documento" => "article" "crossmark" => 0 "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/" "subdocumento" => "ssu" "cita" => "Nefrologia. 2018;38:27-33" "abierto" => array:3 [ "ES" => true "ES2" => true "LATM" => true ] "gratuito" => true "lecturas" => array:2 [ "total" => 5624 "formatos" => array:3 [ "EPUB" => 322 "HTML" => 4550 "PDF" => 752 ] ] "es" => array:13 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Revisión breve</span>" "titulo" => "Avances en la valoración de la salud ósea en el trasplantado renal" "tienePdf" => "es" "tieneTextoCompleto" => "es" "tieneResumen" => array:2 [ 0 => "es" 1 => "en" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "27" "paginaFinal" => "33" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Advances in the evaluation of bone health in kidney transplant patients" ] ] "contieneResumen" => array:2 [ "es" => true "en" => true ] "contieneTextoCompleto" => array:1 [ "es" => true ] "contienePdf" => array:1 [ "es" => true ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0005" "etiqueta" => "Figura 1" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr1.jpeg" "Alto" => 1981 "Ancho" => 2780 "Tamanyo" => 292090 ] ] "descripcion" => array:1 [ "es" => "<p id="spar0030" class="elsevierStyleSimplePara elsevierViewall">Comparación entre las diferentes pruebas diagnósticas para estimar la salud ósea.</p>" ] ] ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "María José Pérez-Sáez, Daniel Prieto-Alhambra, Adolfo Díez-Pérez, Julio Pascual" "autores" => array:4 [ 0 => array:2 [ "nombre" => "María José" "apellidos" => "Pérez-Sáez" ] 1 => array:2 [ "nombre" => "Daniel" "apellidos" => "Prieto-Alhambra" ] 2 => array:2 [ "nombre" => "Adolfo" "apellidos" => "Díez-Pérez" ] 3 => array:2 [ "nombre" => "Julio" "apellidos" => "Pascual" ] ] ] ] ] "idiomaDefecto" => "es" "Traduccion" => array:1 [ "en" => array:9 [ "pii" => "S2013251417302158" "doi" => "10.1016/j.nefroe.2017.04.018" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => true "ES2" => true "LATM" => true ] "gratuito" => true "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "en" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2013251417302158?idApp=UINPBA000064" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0211699517301030?idApp=UINPBA000064" "url" => "/02116995/0000003800000001/v1_201801090621/S0211699517301030/v1_201801090621/es/main.assets" ] "es" => array:20 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Original</span>" "titulo" => "Valoración del diámetro interno del dializador en hemodiafiltración <span class="elsevierStyleItalic">on-line</span>" "tieneTextoCompleto" => true "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "34" "paginaFinal" => "40" ] ] "autores" => array:1 [ 0 => array:4 [ "autoresLista" => "Francisco Maduell, Raquel Ojeda, Lara Belmar, Paula Munguía, Cristina Sango, Ana Isabel Martinez-Díaz, Marta Arias-Guillén, Manel Vera, Néstor Fontseré, Miquel Gómez, Lida Rodas, Nayra Rico" "autores" => array:12 [ 0 => array:4 [ "nombre" => "Francisco" "apellidos" => "Maduell" "email" => array:1 [ 0 => "fmaduell@clinic.ub.es" ] "referencia" => array:2 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">*</span>" "identificador" => "cor0005" ] ] ] 1 => array:3 [ "nombre" => "Raquel" "apellidos" => "Ojeda" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] ] ] 2 => array:3 [ "nombre" => "Lara" "apellidos" => "Belmar" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] ] ] 3 => array:3 [ "nombre" => "Paula" "apellidos" => "Munguía" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] ] ] 4 => array:3 [ "nombre" => "Cristina" "apellidos" => "Sango" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] ] ] 5 => array:3 [ "nombre" => "Ana Isabel" "apellidos" => "Martinez-Díaz" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] ] ] 6 => array:3 [ "nombre" => "Marta" "apellidos" => "Arias-Guillén" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] ] ] 7 => array:3 [ "nombre" => "Manel" "apellidos" => "Vera" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] ] ] 8 => array:3 [ "nombre" => "Néstor" "apellidos" => "Fontseré" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] ] ] 9 => array:3 [ "nombre" => "Miquel" "apellidos" => "Gómez" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] ] ] 10 => array:3 [ "nombre" => "Lida" "apellidos" => "Rodas" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] ] ] 11 => array:3 [ "nombre" => "Nayra" "apellidos" => "Rico" "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">b</span>" "identificador" => "aff0010" ] ] ] ] "afiliaciones" => array:2 [ 0 => array:3 [ "entidad" => "Servicio de Nefrología, Hospital Clínic, Barcelona, España" "etiqueta" => "a" "identificador" => "aff0005" ] 1 => array:3 [ "entidad" => "Servicio de Bioquímica, Hospital Clínic, Barcelona, España" "etiqueta" => "b" "identificador" => "aff0010" ] ] "correspondencia" => array:1 [ 0 => array:3 [ "identificador" => "cor0005" "etiqueta" => "⁎" "correspondencia" => "<span class="elsevierStyleItalic">Autor para correspondencia</span>." ] ] ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Evaluation of the dialyser inner diameter in online haemodiafiltration" ] ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0010" "etiqueta" => "Figura 2" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr2.jpeg" "Alto" => 1310 "Ancho" => 1625 "Tamanyo" => 75600 ] ] "descripcion" => array:1 [ "es" => "<p id="spar0050" class="elsevierStyleSimplePara elsevierViewall">Variaciones en la dosis de diálisis, medidas por dialisancia iónica, expresada como litros de Kt en las diferentes situaciones de estudio (n<span class="elsevierStyleHsp" style=""></span>=<span class="elsevierStyleHsp" style=""></span>16) ANOVA para datos repetidos.</p>" ] ] ] "textoCompleto" => "<span class="elsevierStyleSections"><span id="sec0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0065">Introducción</span><p id="par0005" class="elsevierStylePara elsevierViewall">La hemodiafiltración <span class="elsevierStyleItalic">on-line</span> (HDF-OL) con alto volumen de reposición combina el tratamiento difusivo con el convectivo, permite un mayor aclaramiento de solutos de mediano y alto peso molecular y mejora la tolerancia hemodinámica intradiálisis<a class="elsevierStyleCrossRefs" href="#bib0135"><span class="elsevierStyleSup">1,2</span></a>. El estudio ESHOL<a class="elsevierStyleCrossRef" href="#bib0145"><span class="elsevierStyleSup">3</span></a> demostró que la HDF-OL posdilucional reduce la mortalidad por cualquier causa respecto a la hemodiálisis (HD) en pacientes prevalentes en HD. Posteriormente, la inclusión de los principales ensayos clínicos aleatorizados en un <span class="elsevierStyleItalic">pooling project</span> con más de 2.700 pacientes<a class="elsevierStyleCrossRef" href="#bib0150"><span class="elsevierStyleSup">4</span></a> y varios metaanálisis<a class="elsevierStyleCrossRefs" href="#bib0155"><span class="elsevierStyleSup">5,6</span></a> ha confirmado la disminución de la mortalidad global y cardiovascular. En un análisis <span class="elsevierStyleItalic">post hoc</span>, los 3<span class="elsevierStyleHsp" style=""></span>ensayos clínicos que tenían la mortalidad como variable principal<a class="elsevierStyleCrossRefs" href="#bib0145"><span class="elsevierStyleSup">3,7,8</span></a> observaron una asociación entre el volumen convectivo y la supervivencia. A raíz de estos resultados se ha recomendado conseguir un volumen de sustitución superior a 21 L por sesión<a class="elsevierStyleCrossRef" href="#bib0175"><span class="elsevierStyleSup">9</span></a>.</p><p id="par0010" class="elsevierStylePara elsevierViewall">Los principales factores limitantes en la consecución de altos volúmenes convectivos son el flujo de sangre (Qb), el tiempo y el dializador. La industria farmacéutica ha mejorado los dializadores optimizando el tamaño del poro para conseguir mayores volúmenes de sustitución y mayor depuración<a class="elsevierStyleCrossRefs" href="#bib0180"><span class="elsevierStyleSup">10,11</span></a>. Sin embargo, la cuestión del diámetro interno de las fibras capilares del dializador resulta contradictoria en la literatura. En el año 2000, Ronco et al.<a class="elsevierStyleCrossRef" href="#bib0190"><span class="elsevierStyleSup">12</span></a>, en un estudio <span class="elsevierStyleItalic">in vitro</span> e <span class="elsevierStyleItalic">in vivo</span> en HD, mostraron que la reducción del diámetro interno se asoció con un aumento de la filtración proximal y retrofiltración distal, lo que mejoró, a través de un mayor volumen convectivo interno, la depuración de grandes moléculas. Recomendaron reducir el diámetro interno de 200<span class="elsevierStyleHsp" style=""></span>μm (estándar en aquellos años) a uno inferior, siempre que se disponga de un líquido de diálisis ultrapuro. Sin embargo, con el progresivo crecimiento de la HDF-OL, la industria farmacéutica ha ofrecido nuevamente dializadores con un diámetro interno superior, probablemente para reducir la presión de entrada de sangre al dializador, ya que, en algunos monitores, condicionaba la presión transmembrana. Con el fin de clarificar este aspecto, el objetivo del estudio fue valorar el efecto del aumento del diámetro interno de las fibras capilares sobre el volumen convectivo y la capacidad depurativa.</p></span><span id="sec0010" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0070">Material y métodos</span><p id="par0015" class="elsevierStylePara elsevierViewall">Estudio monocéntrico en pacientes estables en HDF-OL. Se incluyeron 16 pacientes (12 varones y 4 mujeres) con una edad media de 64,1<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>13 años (intervalo 42-91 años) que se encontraban en programa de HD con un promedio de 64<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>67 meses (intervalo 5-251 meses). La etiología de la insuficiencia renal crónica fue 4<span class="elsevierStyleHsp" style=""></span>glomerulonefritis crónicas (10,8%), 3<span class="elsevierStyleHsp" style=""></span>nefropatías diabéticas (8,1%), 2<span class="elsevierStyleHsp" style=""></span>poliquistosis (5,4%), 2<span class="elsevierStyleHsp" style=""></span>nefropatías vasculares (5,4%), 3<span class="elsevierStyleHsp" style=""></span>por causas urológicas (8,1%), una enfermedad sistémica (2,7%) y una de etiología no filiada (2,7%). Todos los pacientes se dializaron a través de fístula arteriovenosa excepto uno, que se dializó a través de fístula protésica. La anticoagulación utilizada fue heparina de bajo peso molecular (tinzaparina) en el 50%, heparina sódica en el 25% de los pacientes y el 25% restante se dializaron sin heparina.</p><p id="par0020" class="elsevierStylePara elsevierViewall">Cada paciente fue analizado en 4 sesiones, siempre a mitad de semana, en las que se varió el diámetro interno de las fibras capilares del dializador, 185<span class="elsevierStyleHsp" style=""></span>μm (FX60 Cordiax y FX80 Cordiax) versus 210<span class="elsevierStyleHsp" style=""></span>μm (FX600 Cordiax y FX800 Cordiax). Las características completas de los dializadores están recogidas en la <a class="elsevierStyleCrossRef" href="#tbl0005">tabla 1</a>. Se mantuvieron constantes en cada una de las sesiones estudiadas los demás parámetros dialíticos: membrana de helixona plus; tiempo de diálisis, 293<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>17<span class="elsevierStyleHsp" style=""></span>min (240-300<span class="elsevierStyleHsp" style=""></span>min); flujo del baño de diálisis (Qd) 400<span class="elsevierStyleHsp" style=""></span>ml/min y monitor 5008 Cordiax, HDF-OL posdilucional con sistema de autosustitución. Se aleatorizó el orden de las sesiones. Los parámetros de diálisis recogidos en cada sesión fueron: tiempo programado, duración real, dializador, Qb, Qd, calibre de las agujas, Kt medido automáticamente por dialisancia iónica, índice de recirculación medido por el módulo de temperatura, presión arterial, presión venosa, presión transmembrana, hematocrito inicial y final, ultrafiltración, volumen de sangre procesada y volumen de sustitución.</p><elsevierMultimedia ident="tbl0005"></elsevierMultimedia><p id="par0025" class="elsevierStylePara elsevierViewall">Analíticamente se determinaron las concentraciones de urea (60<span class="elsevierStyleHsp" style=""></span>Da), creatinina (113<span class="elsevierStyleHsp" style=""></span>Da), β<span class="elsevierStyleInf">2</span>-microglobulina (11.800<span class="elsevierStyleHsp" style=""></span>Da), mioglobina (17.200<span class="elsevierStyleHsp" style=""></span>Da), prolactina (23.000<span class="elsevierStyleHsp" style=""></span>Da), α<span class="elsevierStyleInf">1</span>-microglobulina (33.000<span class="elsevierStyleHsp" style=""></span>Da) y α<span class="elsevierStyleInf">1</span>-glicoproteína ácida (41.000<span class="elsevierStyleHsp" style=""></span>Da) y albúmina (66.000<span class="elsevierStyleHsp" style=""></span>Da) en suero al inicio y al final de cada sesión para calcular el porcentaje de reducción de estos solutos. La concentración final de β<span class="elsevierStyleInf">2</span>-microglobulina, mioglobina, prolactina, α<span class="elsevierStyleInf">1</span>-microglobulina, α<span class="elsevierStyleInf">1</span>-glicoproteína y albúmina se corrigieron para la hemoconcentración y el volumen de distribución (aproximadamente el volumen extracelular) según Bergström y Wehle<a class="elsevierStyleCrossRef" href="#bib0195"><span class="elsevierStyleSup">13</span></a>. Las concentraciones de urea, creatinina y albúmina se midieron por espectrometría de absorción molecular en el analizador ADVIA 2400 (Chemistry System de Siemens Healthineers, Tarrytown, EE. UU.). La β<span class="elsevierStyleInf">2</span>-microglobulina y la α<span class="elsevierStyleInf">1</span>-glicoproteína ácida se midieron por inmunonefelometría con el analizador Dimension Vista (Siemens Healthineers) y la α<span class="elsevierStyleInf">1</span>-microglobulina por inmunonefelometría por el analizador BNII (Siemens Healthineers). Las concentraciones de mioglobina se midieron por enzimoinmunoanálisis de tipo «sandwich» con el analizador Dimension EXL (Siemens Healthineers). Las concentraciones de prolactina se midieron por enzimoinmunoanálisis de tipo «sandwich» con el analizador ADVIA Centaur (Siemens Healthineers).</p><p id="par0030" class="elsevierStylePara elsevierViewall">En todos los casos se utilizaron reactivos dedicados. Los valores de referencia de nuestro laboratorio son 10-50<span class="elsevierStyleHsp" style=""></span>mg/dl para la urea, 0,3-1,3<span class="elsevierStyleHsp" style=""></span>mg/dl para la creatinina, 0,1-2,3<span class="elsevierStyleHsp" style=""></span>mg/L para la β<span class="elsevierStyleInf">2</span>-microglobulina, 0-100<span class="elsevierStyleHsp" style=""></span>ng/ml para la mioglobina, 2,8-15<span class="elsevierStyleHsp" style=""></span>ng/ml para la prolactina, 5-25<span class="elsevierStyleHsp" style=""></span>mg/L para α<span class="elsevierStyleInf">1</span>-microglobulina, 0,38-1,18<span class="elsevierStyleHsp" style=""></span>g/L para la α<span class="elsevierStyleInf">1</span>-glicoproteína ácida y 34-48<span class="elsevierStyleHsp" style=""></span>g/l para la albúmina.</p><p id="par0035" class="elsevierStylePara elsevierViewall">Asimismo, se recogió una parte proporcional del líquido de diálisis para cuantificar la pérdida de solutos y también de albúmina. La urea, creatinina y prolactina se midieron igual que en suero. Sin embargo, como las concentraciones de β<span class="elsevierStyleInf">2</span>-microglobulina y de albúmina eran muy bajas, fue necesario analizar dichas magnitudes con la misma tecnología, pero con los métodos de determinación en orina para aumentar la sensibilidad analítica. La β<span class="elsevierStyleInf">2</span>-microglobulina se midió con un mejor índice de detección: 0,004625<span class="elsevierStyleHsp" style=""></span>mg/l.</p><p id="par0040" class="elsevierStylePara elsevierViewall">Los resultados se expresan como la media aritmética<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>desviación típica. Para el análisis de la significación estadística de parámetros cuantitativos se ha empleado el test de la t de Student para datos pareados y ANOVA para datos repetidos. Se ha considerado estadísticamente significativa una p<span class="elsevierStyleHsp" style=""></span><<span class="elsevierStyleHsp" style=""></span>0,05.</p></span><span id="sec0015" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0075">Resultados</span><p id="par0045" class="elsevierStylePara elsevierViewall">Todas las sesiones de diálisis se realizaron sin incidencias clínicas destacables. No hubo ninguna sesión con coagulación de las líneas o del dializador. No hubo diferencias en los parámetros de diálisis, Qb, sangre total procesada por el monitor, Qd, duración real de las sesiones, peso inicial, peso final, ganancia de peso, mediciones por el propio monitor de diálisis del hematocrito inicial y final, tamaño de las agujas, recirculación del acceso vascular, presión arterial, presión venosa o presión transmembrana (<a class="elsevierStyleCrossRef" href="#tbl0010">tabla 2</a>).</p><elsevierMultimedia ident="tbl0010"></elsevierMultimedia><p id="par0050" class="elsevierStylePara elsevierViewall">El incremento de diámetro interno en las 2<span class="elsevierStyleHsp" style=""></span>series de comparaciones no reflejó incremento en el volumen de reposición (29,61<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3,5 con FX60 Cordiax vs. 29,07<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3,8 L/sesión con FX600 Cordiax y 30,99<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,5 con FX80 Cordiax vs. 30,83<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,1 L/sesión con FX800 Cordiax) ni tampoco, lógicamente en el volumen convectivo total (<a class="elsevierStyleCrossRef" href="#fig0005">fig. 1</a>).</p><elsevierMultimedia ident="fig0005"></elsevierMultimedia><p id="par0055" class="elsevierStylePara elsevierViewall">El incremento del diámetro interno de las fibras del dializador no mostró diferencias significativas de la dosis de diálisis, expresada como Kt (71,4<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>5,7 con FX60 Cordiax vs. 73,4<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>5,9<span class="elsevierStyleHsp" style=""></span>L con FX600 Cordiax y 72,4<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>7,0 con FX80 Cordiax vs.74,4<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>7,9<span class="elsevierStyleHsp" style=""></span>L con FX800 Cordiax) (<a class="elsevierStyleCrossRef" href="#fig0010">fig. 2</a>), ni tampoco como porcentaje de reducción de urea (<a class="elsevierStyleCrossRef" href="#tbl0015">tabla 3</a>).</p><elsevierMultimedia ident="fig0010"></elsevierMultimedia><elsevierMultimedia ident="tbl0015"></elsevierMultimedia><p id="par0060" class="elsevierStylePara elsevierViewall">El porcentaje de reducción del resto de los solutos (creatinina, β<span class="elsevierStyleInf">2</span>-microglobulina, mioglobina, prolactina, α<span class="elsevierStyleInf">1</span>-microglobulina y α<span class="elsevierStyleInf">1</span>-glicoproteína ácida) se recoge en la <a class="elsevierStyleCrossRef" href="#tbl0015">tabla 3</a>. Se puede observar que no hay diferencias significativas en estos porcentajes de reducción de solutos entre la variación del diámetro interno ni tampoco entre los 2<span class="elsevierStyleHsp" style=""></span>tipos de dializadores comparados. Tampoco se observaron diferencias significativas en la albúmina eliminada en el líquido de diálisis en ninguna de las 2<span class="elsevierStyleHsp" style=""></span>series de comparaciones: 2,7<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>1,8<span class="elsevierStyleHsp" style=""></span>g para FX60 Cordiax vs. 1,6<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0,9<span class="elsevierStyleHsp" style=""></span>g con FX600 Cordiax y 3,2<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>1,9<span class="elsevierStyleHsp" style=""></span>g con FX80 Cordiax vs. 3,0<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>1,9<span class="elsevierStyleHsp" style=""></span>g con FX800 Cordiax.</p></span><span id="sec0020" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0080">Discusión</span><p id="par0065" class="elsevierStylePara elsevierViewall">El presente estudio muestra que, en HDF-OL posdilucional, la comparación de 2<span class="elsevierStyleHsp" style=""></span>series de dializadores con diámetros internos de fibra capilar de 185 y 210<span class="elsevierStyleHsp" style=""></span>μm no mostró diferencias sobre el volumen convectivo y la eficacia depurativa. Revisada la literatura, el presente estudio representa el primer estudio en HDF-OL en que se compara el diámetro interno sin variar el resto de los parámetros de diálisis. El volumen convectivo alcanzado, que varió entre 29 y 31 L por sesión, era adecuado, si bien no se observaron diferencias estadísticamente significativas en ninguna de las 2<span class="elsevierStyleHsp" style=""></span>series comparadas. En términos de eficacia, tampoco fueron observadas diferencias significativas en la reducción de solutos de pequeño y alto peso molecular.</p><p id="par0070" class="elsevierStylePara elsevierViewall">La efectividad del tratamiento con HD se mide en términos de supervivencia, morbilidad y calidad de vida obtenida tanto durante la sesión de diálisis como en el período interdiálisis. La HDF-OL combina el trasporte difusivo y permite un aumento considerable del transporte convectivo<a class="elsevierStyleCrossRef" href="#bib0200"><span class="elsevierStyleSup">14</span></a>, lo que permite un mayor aclaramiento de moléculas de mediano y alto peso molecular<a class="elsevierStyleCrossRefs" href="#bib0205"><span class="elsevierStyleSup">15,16</span></a>. La HDF-OL es una técnica segura que mejora la tolerancia hemodinámica intradiálisis<a class="elsevierStyleCrossRefs" href="#bib0135"><span class="elsevierStyleSup">1,3</span></a>, contribuye, entre otras, a la corrección de la anemia, el estado inflamatorio crónico, la amiloidosis, el hiperparatiroidismo, el estrés oxidativo y el perfil lipídico<a class="elsevierStyleCrossRefs" href="#bib0215"><span class="elsevierStyleSup">17–19</span></a>, y que aumenta la supervivencia<a class="elsevierStyleCrossRefs" href="#bib0145"><span class="elsevierStyleSup">3–6</span></a> y la calidad de vida<a class="elsevierStyleCrossRefs" href="#bib0150"><span class="elsevierStyleSup">4,20</span></a>.</p><p id="par0075" class="elsevierStylePara elsevierViewall">A lo largo de los últimos años se han desarrollado nuevos dializadores con mayor superficie, mejor disposición geométrica de las fibras capilares, variación del espesor de pared, mayor tamaño de los poros, con el fin de conseguir una mayor depuración tanto de moléculas pequeñas como de medianas-grandes. El filtro ideal debe acercarse a las siguientes características: alta depuración de moléculas pequeñas; elevado coeficiente de cribado para β<span class="elsevierStyleInf">2</span>-microglobulina y mioglobina; bajo coeficiente de cribado para la albúmina; presiones transmembranas bajas que no limiten el flujo de infusión; poseer un gran poder de atrapamiento de endotoxinas y una buena relación calidad-precio<a class="elsevierStyleCrossRef" href="#bib0235"><span class="elsevierStyleSup">21</span></a>.</p><p id="par0080" class="elsevierStylePara elsevierViewall">La capacidad convectiva de los dializadores atiende a la ley de Hagen-Poiseuille Δp=Qb×8ηl/π.r4, la caída de presión en el interior de la fibra del dializador es directamente proporcional al Qb, la longitud (l) y la viscosidad sanguínea η e inversamente proporcional al diámetro interno r4. Una caída de presión en el interior de la fibra incrementará el gradiente de presión entre el compartimento sanguíneo y el compartimento de diálisis, dando lugar a un mayor transporte convectivo. Teniendo en cuenta que <span class="elsevierStyleItalic">Δp</span><span class="elsevierStyleHsp" style=""></span>∼<span class="elsevierStyleHsp" style=""></span>1/<span class="elsevierStyleItalic">r</span><span class="elsevierStyleSup">4</span>, una mínima reducción del diámetro de la fibra capilar tiene un gran impacto en la caída de presión en su interior, lo que incrementará el gradiente de presión entre la sangre y el líquido de diálisis a lo largo de toda la longitud de la fibra, con mejora tanto de la difusión como de la convección. En términos de eficacia, mientras el incremento de la difusión apenas implica variación en el aclaramiento de pequeñas moléculas, un mayor trasporte convectivo origina un mayor aclaramiento de moléculas de elevado peso molecular.</p><p id="par0085" class="elsevierStylePara elsevierViewall">En un estudio previo<a class="elsevierStyleCrossRef" href="#bib0240"><span class="elsevierStyleSup">22</span></a>, se puso de manifiesto que el aumento del Qb probablemente sea la mejor opción para alcanzar el mayor volumen convectivo. Por cada 50<span class="elsevierStyleHsp" style=""></span>ml/min de incremento del Qb, el volumen convectivo aumenta más de medio litro por hora. El Qb aumenta la capacidad depurativa de las moléculas pequeñas y favorece la de la β<span class="elsevierStyleInf">2</span>-microglobulina y la mioglobina. En otro estudio<a class="elsevierStyleCrossRef" href="#bib0245"><span class="elsevierStyleSup">23</span></a> se valoró el efecto del aumento de la superficie del dializador, y se concluyó que el incremento de la superficie del dializador originaba un pequeño incremento del volumen convectivo sin evidenciar una mejoría en la capacidad depurativa, especialmente si el coeficiente de ultrafiltración era superior a 45<span class="elsevierStyleHsp" style=""></span>ml/h/mmHg. En el presente estudio, no observamos variaciones significativas de volumen convectivo en ninguna de las 2<span class="elsevierStyleHsp" style=""></span>series comparadas. A diferencia del estudio anterior, en el presente, además de un incremento del diámetro interno de la fibra capilar del dializador de 185<span class="elsevierStyleHsp" style=""></span>μm a 210<span class="elsevierStyleHsp" style=""></span>μm, se acompañó de un pequeño aumento de 0,2 m<span class="elsevierStyleSup">2</span> la superficie del dializador (1,4 m<span class="elsevierStyleSup">2</span> para FX CorDiax 60 vs. 1,6 m<span class="elsevierStyleSup">2</span> para FX CorDiax 600 y 1,8 m<span class="elsevierStyleSup">2</span> para FX CorDiax 80 vs. 2,0 m<span class="elsevierStyleSup">2</span> para FX CorDiax 800). Por tanto, entendemos que la no variación observada en el volumen convectivo puede ser el resultado de las variaciones opuestas, derivadas de un incremento simultáneo de superficie y diámetro que pueden compensarse entre sí.</p><p id="par0090" class="elsevierStylePara elsevierViewall">Son limitadas las referencias sobre los efectos de la variación del diámetro interno de las fibras capilares con relación al volumen convectivo y la capacidad depurativa de los dializadores. Dellanna et al.<a class="elsevierStyleCrossRef" href="#bib0250"><span class="elsevierStyleSup">24</span></a> testaron en 10 pacientes en HD de alto flujo 3<span class="elsevierStyleHsp" style=""></span>tipos de dializadores de polisulfona con idéntico número y longitud de fibras, con diámetros internos de 175, 200 y 250<span class="elsevierStyleHsp" style=""></span>μm, superficies de 0,55, 0,65 y 0,79 m<span class="elsevierStyleSup">2</span>, y coeficientes de cribado para β<span class="elsevierStyleInf">2</span>-microglobulina 0,82, 0,79 y 0,71, respectivamente. Con Qb 250 y Qd 500<span class="elsevierStyleHsp" style=""></span>ml/min no observaron apenas variación en el aclaramiento de pequeñas moléculas como la urea o la creatinina. Por el contrario, el dializador con menor diámetro (175<span class="elsevierStyleHsp" style=""></span>μm), a pesar de ser el de menor superficie, mostró un aclaramiento de β<span class="elsevierStyleInf">2</span>-microglobulina del doble del mostrado por el dializador de 200<span class="elsevierStyleHsp" style=""></span>μm y casi 5<span class="elsevierStyleHsp" style=""></span>veces superior al de 250<span class="elsevierStyleHsp" style=""></span>μm. Ronco et al.<a class="elsevierStyleCrossRef" href="#bib0190"><span class="elsevierStyleSup">12</span></a>, también en HD, compararon <span class="elsevierStyleItalic">in vitro</span> e <span class="elsevierStyleItalic">in vivo</span> 2<span class="elsevierStyleHsp" style=""></span>tipos de dializadores de alto flujo con fibra hueca de polisulfona, de 0,7 m<span class="elsevierStyleSup">2</span> de superficie, uno estándar con un diámetro de 200<span class="elsevierStyleHsp" style=""></span>μm y otro modificado a un diámetro interno de fibra de 175<span class="elsevierStyleHsp" style=""></span>μm, respectivamente. Con parámetros de diálisis de Qb 300 y Qd 500<span class="elsevierStyleHsp" style=""></span>ml/min, observaron <span class="elsevierStyleItalic">in vitro</span> un incremento de la filtración interna y retrofiltración de 23,1<span class="elsevierStyleHsp" style=""></span>ml/min en el dializador con fibras de 200<span class="elsevierStyleHsp" style=""></span>μm a 48,2<span class="elsevierStyleHsp" style=""></span>ml/min en el dializador de 175<span class="elsevierStyleHsp" style=""></span>μm. Los estudios <span class="elsevierStyleItalic">in vivo</span> objetivaron que la reducción del diámetro supuso un incremento del 30% en el aclaramiento de solutos intermedios como la vitamina B<span class="elsevierStyleInf">12</span> o la inulina. Resultados similares obtuvieron Mineshima et al.<a class="elsevierStyleCrossRef" href="#bib0255"><span class="elsevierStyleSup">25</span></a>. En un estudio analítico-experimental analizaron los efectos del diámetro interno de las fibras capilares sobre la filtración interna y la eficiencia en la eliminación de solutos en HD. Evaluaron 5 dializadores de la misma superficie (1,5 m<span class="elsevierStyleSup">2</span>) y diámetros internos de 150, 175 y 3<span class="elsevierStyleHsp" style=""></span>sesiones con 200<span class="elsevierStyleHsp" style=""></span>μm variando el número y la longitud de las fibras capilares. Objetivaron que una disminución del diámetro interno de las fibras capilares incrementaba la filtración interna y aumentaba el aclaramiento de mioglobina. En este mismo estudio ponen de manifiesto que una excesiva reducción del diámetro interno puede suponer un mayor riesgo de hemólisis y transferencia de contaminantes biológicos, por lo que proponían que la reducción del diámetro interno no origine una caída de presión interna superior a 150<span class="elsevierStyleHsp" style=""></span>mmHg, por la propia seguridad del paciente<a class="elsevierStyleCrossRef" href="#bib0255"><span class="elsevierStyleSup">25</span></a>.</p><p id="par0095" class="elsevierStylePara elsevierViewall">No hemos encontrado en la literatura estudios comparativos del diámetro interno en HDF-OL. En un estudio que analizó los factores asociados a conseguir un mayor volumen convectivo, Marcelli et al.<a class="elsevierStyleCrossRef" href="#bib0260"><span class="elsevierStyleSup">26</span></a> observaron un volumen convectivo de 25,1<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,1<span class="elsevierStyleHsp" style=""></span>L en 325 pacientes con FX60 en comparación con 27,3<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,6<span class="elsevierStyleHsp" style=""></span>L en 2.572 pacientes con FX600. Sin embargo, estos 2,2 L de diferencia no pueden atribuirse al cambio del diámetro interno sino al aumento del Qb (352<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>54 vs. 361<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>70) y a la duración del tratamiento (241<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>11 vs. 255<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>19).</p><p id="par0100" class="elsevierStylePara elsevierViewall">Concluimos que el incremento del diámetro interno de las fibras capilares en HDF-OL no ha significado una mayor eficacia en el volumen convectivo ni en la capacidad depurativa. Por tanto, el diámetro interno en dializadores con elevado coeficiente de ultrafiltración no parece ser un factor limitante en el volumen convectivo, como lo es el flujo de sangre o el tiempo de diálisis.</p></span><span id="sec0025" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0085">Conflicto de intereses</span><p id="par0105" class="elsevierStylePara elsevierViewall">Los autores declaran no tener ningún conflicto de intereses.</p></span></span>" "textoCompletoSecciones" => array:1 [ "secciones" => array:11 [ 0 => array:3 [ "identificador" => "xres968865" "titulo" => "Resumen" "secciones" => array:4 [ 0 => array:2 [ "identificador" => "abst0005" "titulo" => "Introducción" ] 1 => array:2 [ "identificador" => "abst0010" "titulo" => "Material y métodos" ] 2 => array:2 [ "identificador" => "abst0015" "titulo" => "Resultados" ] 3 => array:2 [ "identificador" => "abst0020" "titulo" => "Conclusión" ] ] ] 1 => array:2 [ "identificador" => "xpalclavsec939864" "titulo" => "Palabras clave" ] 2 => array:3 [ "identificador" => "xres968866" "titulo" => "Abstract" "secciones" => array:4 [ 0 => array:2 [ "identificador" => "abst0025" "titulo" => "Introduction" ] 1 => array:2 [ "identificador" => "abst0030" "titulo" => "Material and methods" ] 2 => array:2 [ "identificador" => "abst0035" "titulo" => "Results" ] 3 => array:2 [ "identificador" => "abst0040" "titulo" => "Conclusion" ] ] ] 3 => array:2 [ "identificador" => "xpalclavsec939865" "titulo" => "Keywords" ] 4 => array:2 [ "identificador" => "sec0005" "titulo" => "Introducción" ] 5 => array:2 [ "identificador" => "sec0010" "titulo" => "Material y métodos" ] 6 => array:2 [ "identificador" => "sec0015" "titulo" => "Resultados" ] 7 => array:2 [ "identificador" => "sec0020" "titulo" => "Discusión" ] 8 => array:2 [ "identificador" => "sec0025" "titulo" => "Conflicto de intereses" ] 9 => array:2 [ "identificador" => "xack328125" "titulo" => "Agradecimientos" ] 10 => array:1 [ "titulo" => "Bibliografía" ] ] ] "pdfFichero" => "main.pdf" "tienePdf" => true "fechaRecibido" => "2017-02-08" "fechaAceptado" => "2017-03-16" "PalabrasClave" => array:2 [ "es" => array:1 [ 0 => array:4 [ "clase" => "keyword" "titulo" => "Palabras clave" "identificador" => "xpalclavsec939864" "palabras" => array:4 [ 0 => "Dializador" 1 => "Diámetro interno" 2 => "Hemodiafiltración <span class="elsevierStyleItalic">on-line</span>" 3 => "Volumen convectivo" ] ] ] "en" => array:1 [ 0 => array:4 [ "clase" => "keyword" "titulo" => "Keywords" "identificador" => "xpalclavsec939865" "palabras" => array:4 [ 0 => "Dialyser" 1 => "Inner diameter" 2 => "Online haemodiafiltration" 3 => "Convective volume" ] ] ] ] "tieneResumen" => true "resumen" => array:2 [ "es" => array:3 [ "titulo" => "Resumen" "resumen" => "<span id="abst0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0010">Introducción</span><p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">Se ha asociado la hemodiafiltración <span class="elsevierStyleItalic">on-line</span> (HDF-OL) a un aumento de la supervivencia. Hasta el momento no está bien establecida la influencia del diámetro interno de las fibras capilares del dializador sobre la capacidad convectiva. El objetivo del estudio fue valorar el efecto del aumento del diámetro interno del dializador sobre el volumen convectivo y la capacidad depurativa.</p></span> <span id="abst0010" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0015">Material y métodos</span><p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">Se incluyeron 16 pacientes en HDF-OL posdilucional con reposición automática. Cada paciente recibió 4 sesiones, en las que se varió el diámetro interno, 185<span class="elsevierStyleHsp" style=""></span>μm (FX60 Cordiax y FX80 Cordiax) versus 210<span class="elsevierStyleHsp" style=""></span>μm (FX600 Cordiax y FX800 Cordiax). En cada sesión se determinaron diferentes solutos al inicio y al final de la diálisis.</p></span> <span id="abst0015" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0020">Resultados</span><p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">El incremento de diámetro interno entre FX60 vs. FX600 y FX80 vs. FX800 no reflejó diferencias en el volumen convectivo: 32,3<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3,1 vs. 31,8<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3,6 y 33,7<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,3 vs. 33,5<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3,8<span class="elsevierStyleHsp" style=""></span>L/sesión, respectivamente. Los porcentajes de reducción tampoco mostraron diferencias: urea 83,7<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,5 vs. 84,1<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3,4 para FX60 y FX600 y 82,7<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,1 vs. 83,6<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3,8 para FX80 vs. FX800; creatinina similar 78,2<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>5,6 vs. 77,8<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,6 y 77,1<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>5,4 vs. 78,1<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,9; β<span class="elsevierStyleInf">2</span>-microglobulina 82,2<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,3 vs. 82,9<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,2 y 82,9<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,7 vs. 84,0<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3,8; mioglobina 71,0<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>10, vs. 70,2<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>9 y 72,8<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>11 vs. 75,0<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>10; prolactina 70,4<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>9 vs. 68,1<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>9 y 72,2<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>10 vs. 73,4<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>8,2; y α<span class="elsevierStyleInf">1</span>-microglobulina 22,9<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>10 vs. 21,6<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>10 y 26,5<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>12 vs. 28,8<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>11, respectivamente.</p></span> <span id="abst0020" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0025">Conclusión</span><p id="spar0020" class="elsevierStyleSimplePara elsevierViewall">El incremento del diámetro interno de las fibras capilares no ha significado una mayor eficacia en el volumen convectivo ni en la capacidad depurativa.</p></span>" "secciones" => array:4 [ 0 => array:2 [ "identificador" => "abst0005" "titulo" => "Introducción" ] 1 => array:2 [ "identificador" => "abst0010" "titulo" => "Material y métodos" ] 2 => array:2 [ "identificador" => "abst0015" "titulo" => "Resultados" ] 3 => array:2 [ "identificador" => "abst0020" "titulo" => "Conclusión" ] ] ] "en" => array:3 [ "titulo" => "Abstract" "resumen" => "<span id="abst0025" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0035">Introduction</span><p id="spar0025" class="elsevierStyleSimplePara elsevierViewall">Online haemodiafiltration (OL-HDF) has been associated with increased survival. To date, the influence of the inner diameter of the hollow fibres of the dialyser on convective volume has not been well established. The objective of the study was to evaluate the effect of increasing the inner diameter of the dialyser on the convective volume and removal capacity.</p></span> <span id="abst0030" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0040">Material and methods</span><p id="spar0030" class="elsevierStyleSimplePara elsevierViewall">We included 16 patients in posdilutional OL-HDF with autosubstitution. Each patient was analysed in 4 sessions in which the inner diameter varied; 185<span class="elsevierStyleHsp" style=""></span>μm (FX60 Cordiax and FX80 Cordiax) versus 210<span class="elsevierStyleHsp" style=""></span>μm (FX600 Cordiax and FX800 Cordiax). Different solutes were measured at the beginning and end of each dialysis session.</p></span> <span id="abst0035" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0045">Results</span><p id="spar0035" class="elsevierStyleSimplePara elsevierViewall">No differences in the convective volume were found with an increased inner diameter: 32.3<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3.1 vs. 31.8<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3.6 l/session (FX60 vs. FX600) and 33.7<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4.3 vs. 33.5<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3.8 l/session (FX80 vs. FX800). The reduction percentages also did not differ: urea 83.7<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4.5 vs. 84.1<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3.4 for FX60 and FX600, and 82.7<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4.1 vs. 83.6<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3.8 for FX80 vs. FX800; creatinine similar 78.2<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>5.6 vs. 77.8<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4.6 y 77.1<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>5.4 vs. 78.1<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4.9; β<span class="elsevierStyleInf">2</span>-microglobulin 82.2<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4.3 vs. 82.9<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4.2, and 82.9<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4.7 vs. 84.0<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3.8; myoglobin 71.0<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>10 vs. 70.2<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>9 and 72.8<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>11 vs. 75.0<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>10; prolactin 70.4<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>9 vs. 68.1<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>9, and 72.2<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>10 vs. 73.4<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>8.2; and α<span class="elsevierStyleInf">1</span>-microglobulin 22.9<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>10 vs. 21.6<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>10, and 26.5<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>12 vs. 28.8<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>11, respectively.</p></span> <span id="abst0040" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0050">Conclusion</span><p id="spar0040" class="elsevierStyleSimplePara elsevierViewall">The increase in the inner diameter of the hollow fibres did not result in improved convective volume and removal capacity.</p></span>" "secciones" => array:4 [ 0 => array:2 [ "identificador" => "abst0025" "titulo" => "Introduction" ] 1 => array:2 [ "identificador" => "abst0030" "titulo" => "Material and methods" ] 2 => array:2 [ "identificador" => "abst0035" "titulo" => "Results" ] 3 => array:2 [ "identificador" => "abst0040" "titulo" => "Conclusion" ] ] ] ] "multimedia" => array:5 [ 0 => array:7 [ "identificador" => "fig0005" "etiqueta" => "Figura 1" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr1.jpeg" "Alto" => 1182 "Ancho" => 1625 "Tamanyo" => 73843 ] ] "descripcion" => array:1 [ "es" => "<p id="spar0045" class="elsevierStyleSimplePara elsevierViewall">Variaciones en el volumen convectivo en hemodiafiltración <span class="elsevierStyleItalic">on line</span> según las situaciones de estudio (n<span class="elsevierStyleHsp" style=""></span>=<span class="elsevierStyleHsp" style=""></span>16) ANOVA para datos repetidos.</p>" ] ] 1 => array:7 [ "identificador" => "fig0010" "etiqueta" => "Figura 2" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr2.jpeg" "Alto" => 1310 "Ancho" => 1625 "Tamanyo" => 75600 ] ] "descripcion" => array:1 [ "es" => "<p id="spar0050" class="elsevierStyleSimplePara elsevierViewall">Variaciones en la dosis de diálisis, medidas por dialisancia iónica, expresada como litros de Kt en las diferentes situaciones de estudio (n<span class="elsevierStyleHsp" style=""></span>=<span class="elsevierStyleHsp" style=""></span>16) ANOVA para datos repetidos.</p>" ] ] 2 => array:8 [ "identificador" => "tbl0005" "etiqueta" => "Tabla 1" "tipo" => "MULTIMEDIATABLA" "mostrarFloat" => true "mostrarDisplay" => false "detalles" => array:1 [ 0 => array:3 [ "identificador" => "at1" "detalle" => "Tabla " "rol" => "short" ] ] "tabla" => array:2 [ "leyenda" => "<p id="spar0060" class="elsevierStyleSimplePara elsevierViewall">CUF: coeficiente de ultrafiltración; KoA: coeficiente de transferencia de masas.</p>" "tablatextoimagen" => array:1 [ 0 => array:2 [ "tabla" => array:1 [ 0 => """ <table border="0" frame="\n \t\t\t\t\tvoid\n \t\t\t\t" class=""><thead title="thead"><tr title="table-row"><th class="td" title="table-head " align="" valign="top" scope="col" style="border-bottom: 2px solid black"> \t\t\t\t\t\t\n \t\t\t\t</th><th class="td" title="table-head " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">FX CorDiax 60 \t\t\t\t\t\t\n \t\t\t\t</th><th class="td" title="table-head " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">FX CorDiax 600 \t\t\t\t\t\t\n \t\t\t\t</th><th class="td" title="table-head " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">FX CorDiax 80 \t\t\t\t\t\t\n \t\t\t\t</th><th class="td" title="table-head " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">FX CorDiax 800 \t\t\t\t\t\t\n \t\t\t\t</th></tr></thead><tbody title="tbody"><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Membrana superficie m<span class="elsevierStyleSup">2</span> \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">Helixona®plus 1,4 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">Helixona®plus 1,6 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">Helixona®plus 1,8 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">Helixona®plus 2,0 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Grosor de pared (μm) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">35 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">35 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">35 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">35 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Diámetro interno (μm) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">185 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">210 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">185 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">210 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">KoA urea (ml/min) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">1164 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">1148 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">1429 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">1365 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">CUF (ml/h/mmHg) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">47 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">46 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">64 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">62 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">CUF (ml/h/mmHg/m<span class="elsevierStyleSup">2</span>)<br>Esterilización \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">33,6<br>Vapor \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">28,8<br>Vapor \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">35,6<br>Vapor \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">31,0<br>Vapor \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Coeficiente de cribado β<span class="elsevierStyleInf">2</span>-microglobulina \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">0,9 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">0,9 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">0,9 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">0,9 \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Coeficiente de cribado mioglobina<br>Coeficiente de cribado albúmina \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">0,5<br><0,001 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">0,5<br><0,001 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">0,5<br><0,001 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">0,5<br><0,001 \t\t\t\t\t\t\n \t\t\t\t</td></tr></tbody></table> """ ] "imagenFichero" => array:1 [ 0 => "xTab1639255.png" ] ] ] ] "descripcion" => array:1 [ "es" => "<p id="spar0055" class="elsevierStyleSimplePara elsevierViewall">Características de los dializadores</p>" ] ] 3 => array:8 [ "identificador" => "tbl0010" "etiqueta" => "Tabla 2" "tipo" => "MULTIMEDIATABLA" "mostrarFloat" => true "mostrarDisplay" => false "detalles" => array:1 [ 0 => array:3 [ "identificador" => "at2" "detalle" => "Tabla " "rol" => "short" ] ] "tabla" => array:2 [ "leyenda" => "<p id="spar0070" class="elsevierStyleSimplePara elsevierViewall">NS: no significativo; Qb: flujo de sangre; Qd: flujo de líquido de diálisis; Td: tiempo de diálisis.</p>" "tablatextoimagen" => array:1 [ 0 => array:2 [ "tabla" => array:1 [ 0 => """ <table border="0" frame="\n \t\t\t\t\tvoid\n \t\t\t\t" class=""><thead title="thead"><tr title="table-row"><th class="td" title="table-head " align="" valign="top" scope="col" style="border-bottom: 2px solid black"> \t\t\t\t\t\t\n \t\t\t\t</th><th class="td" title="table-head " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">FX CorDiax 60 \t\t\t\t\t\t\n \t\t\t\t</th><th class="td" title="table-head " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">FX CorDiax 600 \t\t\t\t\t\t\n \t\t\t\t</th><th class="td" title="table-head " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">FX CorDiax 80 \t\t\t\t\t\t\n \t\t\t\t</th><th class="td" title="table-head " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">FX CorDiax 800 \t\t\t\t\t\t\n \t\t\t\t</th><th class="td" title="table-head " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">p \t\t\t\t\t\t\n \t\t\t\t</th></tr></thead><tbody title="tbody"><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Qd (ml/min) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">400 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">400 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">400 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">400 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Qb (ml/min) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">453<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>34 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">453<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>34 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">453<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>34 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">453<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>34 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Sangre depurada (L) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">127,9<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>13,7 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">128,1<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>13,6 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">127,4<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>13,5 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">127,9<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>13,1 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Agujas \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">15 G \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">15 G \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">15 G \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">15 G \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Recirculación (%) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">13,3<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>2,9 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">14,4<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3,5 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">14,2<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3,3 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">14,2<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3,1 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Td real (min) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">283,4<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>17,0 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">283,4<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>17,0 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">282,8<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>17,0 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">282,9<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>17,0 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Peso inicial (kg) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">72,6<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>18,0 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">72,7<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>18,0 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">72,8<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>18,3 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">72,6<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>18,1 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Peso final (kg) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">69,9<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>17,5 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">70,0<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>17,7 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">70,1<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>17,7 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">69,9<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>17,6 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Ganancia de peso (kg) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">2,7<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>1,0 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">2,7<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0,9 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">2,8<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>1,0 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">2,7<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0,9 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Hematocrito inicial (%) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">29,2<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,3 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">28,9<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,6 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">29,6<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,3 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">29,1<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,3 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Hematocrito final (%) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">36,2<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>5,6 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">35,9<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>6,5 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">36,4<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>5,4 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">36,1<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>5,5 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Presión arterial (mmHg) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">−233<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>18 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">−232<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>21 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">−234<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>18 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">−228<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>18 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Presión venosa (mmHg) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">234<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>26 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">235<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>23 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">223<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>28 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">226<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>25 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Presión transmembrana (mmHg) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">183<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>23 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">192<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>20 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">185<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>25 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">191<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>20 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr></tbody></table> """ ] "imagenFichero" => array:1 [ 0 => "xTab1639254.png" ] ] ] ] "descripcion" => array:1 [ "es" => "<p id="spar0065" class="elsevierStyleSimplePara elsevierViewall">Comparación de los parámetros de diálisis en las 4<span class="elsevierStyleHsp" style=""></span>sesiones</p>" ] ] 4 => array:8 [ "identificador" => "tbl0015" "etiqueta" => "Tabla 3" "tipo" => "MULTIMEDIATABLA" "mostrarFloat" => true "mostrarDisplay" => false "detalles" => array:1 [ 0 => array:3 [ "identificador" => "at3" "detalle" => "Tabla " "rol" => "short" ] ] "tabla" => array:1 [ "tablatextoimagen" => array:1 [ 0 => array:2 [ "tabla" => array:1 [ 0 => """ <table border="0" frame="\n \t\t\t\t\tvoid\n \t\t\t\t" class=""><thead title="thead"><tr title="table-row"><th class="td" title="table-head " align="" valign="top" scope="col" style="border-bottom: 2px solid black"> \t\t\t\t\t\t\n \t\t\t\t</th><th class="td" title="table-head " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">FX CorDiax 60 \t\t\t\t\t\t\n \t\t\t\t</th><th class="td" title="table-head " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">FX CorDiax 600 \t\t\t\t\t\t\n \t\t\t\t</th><th class="td" title="table-head " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">p \t\t\t\t\t\t\n \t\t\t\t</th><th class="td" title="table-head " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">FX CorDiax 80 \t\t\t\t\t\t\n \t\t\t\t</th><th class="td" title="table-head " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">FX CorDiax 800 \t\t\t\t\t\t\n \t\t\t\t</th><th class="td" title="table-head " align="center" valign="top" scope="col" style="border-bottom: 2px solid black">p \t\t\t\t\t\t\n \t\t\t\t</th></tr></thead><tbody title="tbody"><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Urea (60<span class="elsevierStyleHsp" style=""></span>Da) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">83,7<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,5 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">84,1<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3,4 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">82,7<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,1 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">83,6<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3,8 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Creatinina (113 Da) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">78,2<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>5,6 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">77,8<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,6 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">77,1<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>5,4 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">78,1<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,9 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">β2-microglobulina (11.818<span class="elsevierStyleHsp" style=""></span>Da) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">82,2<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,3 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">82,9<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,2 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">82,9<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,7 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">84,0<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>3,8 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Mioglobina (17.200<span class="elsevierStyleHsp" style=""></span>Da) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">71,0<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>10,0 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">70,2<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>9,3 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">72,8<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>11,0 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">75,0<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>10,0 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Prolactina (23.000<span class="elsevierStyleHsp" style=""></span>Da) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">70,4<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>9,3 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">68,1<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>8,6 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">72,3<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>10,0 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">73,4<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>8,2 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">α1-microglobulina (33.000<span class="elsevierStyleHsp" style=""></span>Da) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">22,9<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>10,0 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">21,6<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>9,8 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">26,5<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>12,0 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">28,8<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>11,0 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">α1 glicoproteína ácida (41.000<span class="elsevierStyleHsp" style=""></span>Da) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">15,6<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>8,2 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">11,5<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>5,8 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">17,3<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>9,3 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">15,4<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>7,1 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Albúmina (66.000<span class="elsevierStyleHsp" style=""></span>Da) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">9,2<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>6,7 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">8,9<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>4,9 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">10,1<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>5,8 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">7,8<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>5,2 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">Pérdida de albúmina en el dializado (g) \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">2,7<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>1,8 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">1,6<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>0,9 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">3,2<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>1,9 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="char" valign="top">3,0<span class="elsevierStyleHsp" style=""></span>±<span class="elsevierStyleHsp" style=""></span>1,9 \t\t\t\t\t\t\n \t\t\t\t</td><td class="td" title="table-entry " align="left" valign="top">NS \t\t\t\t\t\t\n \t\t\t\t</td></tr></tbody></table> """ ] "imagenFichero" => array:1 [ 0 => "xTab1639253.png" ] ] ] ] "descripcion" => array:1 [ "es" => "<p id="spar0075" class="elsevierStyleSimplePara elsevierViewall">Porcentaje de reducción de solutos en hemodiálisis</p>" ] ] ] "bibliografia" => array:2 [ "titulo" => "Bibliografía" "seccion" => array:1 [ 0 => array:2 [ "identificador" => "bibs0005" "bibliografiaReferencia" => array:26 [ 0 => array:3 [ "identificador" => "bib0135" "etiqueta" => "1" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Hemofiltration and hemodiafiltration reduce intradialytic hypotension in ESRD" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "F. Locatelli" 1 => "P. Altieri" 2 => "S. Andrulli" 3 => "P. Bolasco" 4 => "G. Sau" 5 => "L.A. Pedrini" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1681/ASN.2010030280" "Revista" => array:6 [ "tituloSerie" => "J Am Soc Nephrol" "fecha" => "2010" "volumen" => "21" "paginaInicial" => "1798" "paginaFinal" => "1807" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/20813866" "web" => "Medline" ] ] ] ] ] ] ] ] 1 => array:3 [ "identificador" => "bib0140" "etiqueta" => "2" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Effects of high efficiency post-dilution on-line hemodiafiltration or conventional hemodialysis on residual renal function and left ventricular hypertrophy" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "H. Schiffl" 1 => "S.M. Lang" 2 => "R. Fischer" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1007/s11255-012-0336-4" "Revista" => array:6 [ "tituloSerie" => "Int Urol Nephrol." "fecha" => "2013" "volumen" => "45" "paginaInicial" => "1389" "paginaFinal" => "1396" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23225079" "web" => "Medline" ] ] ] ] ] ] ] ] 2 => array:3 [ "identificador" => "bib0145" "etiqueta" => "3" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "High-efficiency postdilution online hemodiafiltration reduces all-cause mortality in hemodialysis patients" "autores" => array:1 [ 0 => array:3 [ "colaboracion" => "ESHOL Study Group" "etal" => true "autores" => array:6 [ 0 => "F. Maduell" 1 => "F. Moreso" 2 => "M. Pons" 3 => "R. Ramos" 4 => "J. Mora-Macià" 5 => "J. Carreras" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1681/ASN.2012080875" "Revista" => array:6 [ "tituloSerie" => "J Am Soc Nephrol" "fecha" => "2013" "volumen" => "24" "paginaInicial" => "487" "paginaFinal" => "497" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23411788" "web" => "Medline" ] ] ] ] ] ] ] ] 3 => array:3 [ "identificador" => "bib0150" "etiqueta" => "4" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "HDF Pooling Project Investigators. Sanne NDT. Haemodiafiltration and mortality in end-stage kidney disease patients: A pooled individual participant data analysis from four randomized controlled trials" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:7 [ 0 => "S.A. Peters" 1 => "M.L. Bots" 2 => "B. Canaud" 3 => "A. Davenport" 4 => "M.P. Grooteman" 5 => "F. Kircelli" 6 => "F. Locatelli" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1093/ndt/gfv349" "Revista" => array:6 [ "tituloSerie" => "Nephrol Dial Transplant" "fecha" => "2016" "volumen" => "31" "paginaInicial" => "978" "paginaFinal" => "984" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26492924" "web" => "Medline" ] ] ] ] ] ] ] ] 4 => array:3 [ "identificador" => "bib0155" "etiqueta" => "5" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Clinical evidence on hemodiafiltration: A systematic review and a meta-analysis" "autores" => array:1 [ 0 => array:3 [ "colaboracion" => "EUDIAL Group" "etal" => false "autores" => array:6 [ 0 => "I.M. Mostovaya" 1 => "P.J. Blankestijn" 2 => "M.L. Bots" 3 => "A. Covic" 4 => "A. Davenport" 5 => "M. Grooteman" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Semin Dial" "fecha" => "2014" "volumen" => "27" "paginaInicial" => "119" "paginaFinal" => "127" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/24738146" "web" => "Medline" ] ] ] ] ] ] ] ] 5 => array:3 [ "identificador" => "bib0160" "etiqueta" => "6" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Convective versus diffusive dialysis therapies for chronic kidney failure: An updated systematic review of randomized controlled trials" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:6 [ 0 => "I. Nistor" 1 => "S.C. Palmer" 2 => "J.C. Craig" 3 => "V. Saglimbene" 4 => "M. Vecchio" 5 => "A. Covic" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1053/j.ajkd.2013.12.004" "Revista" => array:6 [ "tituloSerie" => "Am J Kidney Dis" "fecha" => "2014" "volumen" => "63" "paginaInicial" => "954" "paginaFinal" => "967" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/24434188" "web" => "Medline" ] ] ] ] ] ] ] ] 6 => array:3 [ "identificador" => "bib0165" "etiqueta" => "7" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Effect of online hemodiafiltration on all-cause mortality and cardiovascular outcomes" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "M.P. Grooteman" 1 => "M.A. van den Dorpel" 2 => "M.L. Bots" 3 => "E.L. Penne" 4 => "N.C. van der Weerd" 5 => "A.H. Mazairac" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1681/ASN.2011121140" "Revista" => array:6 [ "tituloSerie" => "J Am Soc Nephrol" "fecha" => "2012" "volumen" => "23" "paginaInicial" => "1087" "paginaFinal" => "1096" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22539829" "web" => "Medline" ] ] ] ] ] ] ] ] 7 => array:3 [ "identificador" => "bib0170" "etiqueta" => "8" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Mortality and cardiovascular events in online haemodiafiltration (OL-HDF) compared with high-flux dialysis: Results from the Turkish OL-HDF Study" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "E. Ok" 1 => "G. Asci" 2 => "H. Toz" 3 => "E.S. Ok" 4 => "F. Kircelli" 5 => "M. Yilmaz" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1093/ndt/gfs407" "Revista" => array:6 [ "tituloSerie" => "Nephrol Dial Transplant" "fecha" => "2013" "volumen" => "28" "paginaInicial" => "192" "paginaFinal" => "202" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23229932" "web" => "Medline" ] ] ] ] ] ] ] ] 8 => array:3 [ "identificador" => "bib0175" "etiqueta" => "9" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Emerging clinical evidence on online hemodiafiltration: Does volume of ultrafiltration matter?" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "B. Canaud" 1 => "S.K. Bowry" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1159/000346371" "Revista" => array:6 [ "tituloSerie" => "Blood Purif" "fecha" => "2013" "volumen" => "35" "paginaInicial" => "55" "paginaFinal" => "62" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23466380" "web" => "Medline" ] ] ] ] ] ] ] ] 9 => array:3 [ "identificador" => "bib0180" "etiqueta" => "10" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Elimination of large uremic toxins by a dialyzer specifically designed for high-volume convective therapies" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "F. Maduell" 1 => "M. Arias-Guillen" 2 => "N. Fontseré" 3 => "R. Ojeda" 4 => "N. Rico" 5 => "M. Vera" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1159/000358214" "Revista" => array:6 [ "tituloSerie" => "Blood Purif" "fecha" => "2014" "volumen" => "37" "paginaInicial" => "125" "paginaFinal" => "130" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/24662288" "web" => "Medline" ] ] ] ] ] ] ] ] 10 => array:3 [ "identificador" => "bib0185" "etiqueta" => "11" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Experimental evaluation of flow and dialysis performance of hollow-fiber dialyzers with different packing densities" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "A. Hirano" 1 => "S. Kida" 2 => "K. Yamamoto" 3 => "K. Sakai" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1007/s10047-011-0620-6" "Revista" => array:6 [ "tituloSerie" => "J Artif Organs" "fecha" => "2012" "volumen" => "15" "paginaInicial" => "168" "paginaFinal" => "175" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22116168" "web" => "Medline" ] ] ] ] ] ] ] ] 11 => array:3 [ "identificador" => "bib0190" "etiqueta" => "12" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Effects of a reduced inner diameter of hollow fibers in hemodialyzers" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "C. Ronco" 1 => "A. Brendolan" 2 => "A. Lupi" 3 => "G. Metry" 4 => "N.W. Levin" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1046/j.1523-1755.2000.00230.x" "Revista" => array:6 [ "tituloSerie" => "Kidney Int" "fecha" => "2000" "volumen" => "58" "paginaInicial" => "809" "paginaFinal" => "817" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/10916106" "web" => "Medline" ] ] ] ] ] ] ] ] 12 => array:3 [ "identificador" => "bib0195" "etiqueta" => "13" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "No change in corrected ß<span class="elsevierStyleInf">2</span>-microglobulin concentration after cuprophane hemodialysis" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "J. Bergström" 1 => "B. Wehle" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Lancet" "fecha" => "1987" "volumen" => "1" "paginaInicial" => "628" "paginaFinal" => "629" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/2894556" "web" => "Medline" ] ] ] ] ] ] ] ] 13 => array:3 [ "identificador" => "bib0200" "etiqueta" => "14" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "The importance of convective transport" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "F. Locatelli" 1 => "C. Manzoni" 2 => "S. Di Filippo" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Kidney Int Suppl" "fecha" => "2002" "volumen" => "80" "paginaInicial" => "115" "paginaFinal" => "120" ] ] ] ] ] ] 14 => array:3 [ "identificador" => "bib0205" "etiqueta" => "15" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Effects of high-flux hemodialysis on clinical outcomes: Results of the HEMO study" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "A.K. Cheung" 1 => "N.W. Levin" 2 => "T. Greene" 3 => "L. Agodoa" 4 => "J. Bailey" 5 => "G. Beck" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "J Am Soc Nephrol" "fecha" => "2003" "volumen" => "14" "paginaInicial" => "3251" "paginaFinal" => "3263" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/14638924" "web" => "Medline" ] ] ] ] ] ] ] ] 15 => array:3 [ "identificador" => "bib0210" "etiqueta" => "16" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Osteocalcin and myoglobin removal in on-line hemodiafiltration versus lowand high-flux hemodialysis" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "F. Maduell" 1 => "V. Navarro" 2 => "M.C. Cruz" 3 => "E. Torregrosa" 4 => "D. Garcia" 5 => "V. Simon" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Am J Kidney Dis" "fecha" => "2002" "volumen" => "40" "paginaInicial" => "582" "paginaFinal" => "589" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/12200811" "web" => "Medline" ] ] ] ] ] ] ] ] 16 => array:3 [ "identificador" => "bib0215" "etiqueta" => "17" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Change from conventional haemodiafiltration to on-line haemodiafiltration" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "F. Maduell" 1 => "C. del Pozo" 2 => "H. Garcia" 3 => "L. Sanchez" 4 => "J. Hdez-Jaras" 5 => "M.D. Albero" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Nephrol Dial Transplant" "fecha" => "1999" "volumen" => "14" "paginaInicial" => "1202" "paginaFinal" => "1207" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/10344362" "web" => "Medline" ] ] ] ] ] ] ] ] 17 => array:3 [ "identificador" => "bib0220" "etiqueta" => "18" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Online haemodiafiltration versus haemodialysis: Stable haematocrit with less erythropoietin and improvement of other relevant blood parameters" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "L. Vaslaki" 1 => "L. Major" 2 => "K. Berta" 3 => "A. Karatson" 4 => "M. Misz" 5 => "F. Pethoe" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1159/000090117" "Revista" => array:6 [ "tituloSerie" => "Blood Purif" "fecha" => "2006" "volumen" => "24" "paginaInicial" => "163" "paginaFinal" => "173" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/16352871" "web" => "Medline" ] ] ] ] ] ] ] ] 18 => array:3 [ "identificador" => "bib0225" "etiqueta" => "19" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Online haemodiafiltration: Effective removal of high molecular weight toxins and improvement in clinical manifestations of chronic haemodialysis patients" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "S.T. Kim" 1 => "C. Yamamoto" 2 => "H. Asabe" 3 => "T. Sato" 4 => "T. Takamiya" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:7 [ "tituloSerie" => "Nephrology (Carlton)" "fecha" => "1996" "volumen" => "2" "numero" => "Supp 1" "paginaInicial" => "S183" "paginaFinal" => "S186" "itemHostRev" => array:3 [ "pii" => "S0140673615002755" "estado" => "S300" "issn" => "01406736" ] ] ] ] ] ] ] 19 => array:3 [ "identificador" => "bib0230" "etiqueta" => "20" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Can dialysis modality influence quality of life in chronic hemodialysis patients? Low-flux hemodialysis versus high-flux hemodiafiltration: A cross-over study" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "K. Kantartzi" 1 => "S. Panagoutsos" 2 => "E. Mourvati" 3 => "A. Roumeliotis" 4 => "K. Leivaditis" 5 => "V. Devetzis" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.3109/0886022X.2012.743858" "Revista" => array:6 [ "tituloSerie" => "Ren Fail" "fecha" => "2013" "volumen" => "35" "paginaInicial" => "216" "paginaFinal" => "221" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23176401" "web" => "Medline" ] ] ] ] ] ] ] ] 20 => array:3 [ "identificador" => "bib0235" "etiqueta" => "21" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Comparación de dializadores en hemodiafiltración en línea" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "F. Maduell" 1 => "V. Navarro" 2 => "J. Hernández-Jaras" 3 => "C. Calvo" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "Nefrologia" "fecha" => "2000" "volumen" => "20" "paginaInicial" => "269" "paginaFinal" => "276" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/10917004" "web" => "Medline" ] ] ] ] ] ] ] ] 21 => array:3 [ "identificador" => "bib0240" "etiqueta" => "22" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Hemodiafiltración on-line con autosustitución: valoración de los cambios del flujo de sangre sobre el volumen convectivo y eficacia" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "F. Maduell" 1 => "R. Ojeda" 2 => "L. Rodas" 3 => "N. Rico" 4 => "N. Fontseré" 5 => "M. Arias" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.3265/Nefrologia.pre2014.Sep.12726" "Revista" => array:6 [ "tituloSerie" => "Nefrologia" "fecha" => "2015" "volumen" => "35" "paginaInicial" => "50" "paginaFinal" => "57" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25611833" "web" => "Medline" ] ] ] ] ] ] ] ] 22 => array:3 [ "identificador" => "bib0245" "etiqueta" => "23" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Valoración de la superficie del dializador en la hemodiafiltración on-line. Elección objetiva de la superficie del dializador" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "F. Maduell" 1 => "R. Ojeda" 2 => "M. Arias-Guillén" 3 => "G. Bazan" 4 => "M. Vera" 5 => "N. Fontseré" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.nefro.2015.05.003" "Revista" => array:6 [ "tituloSerie" => "Nefrologia" "fecha" => "2015" "volumen" => "35" "paginaInicial" => "280" "paginaFinal" => "286" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26299171" "web" => "Medline" ] ] ] ] ] ] ] ] 23 => array:3 [ "identificador" => "bib0250" "etiqueta" => "24" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Internal filtration--advantage in haemodialysis?" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "F. Dellanna" 1 => "A. Wuepper" 2 => "C.A. Baldamus" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:7 [ "tituloSerie" => "Nephrol Dial Transplant" "fecha" => "1996" "volumen" => "11" "numero" => "Suppl 2" "paginaInicial" => "83" "paginaFinal" => "86" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/8804002" "web" => "Medline" ] ] ] ] ] ] ] ] 24 => array:3 [ "identificador" => "bib0255" "etiqueta" => "25" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Effects of internal filtration on the solute removal efficiency of a dialyzer" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "M. Mineshima" 1 => "I. Ishimori" 2 => "K. Ishida" 3 => "T. Hoshino" 4 => "I. Kaneko" 5 => "Y. Sato" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:6 [ "tituloSerie" => "ASAIO J." "fecha" => "2000" "volumen" => "46" "paginaInicial" => "456" "paginaFinal" => "460" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/10926146" "web" => "Medline" ] ] ] ] ] ] ] ] 25 => array:3 [ "identificador" => "bib0260" "etiqueta" => "26" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Modificable factors associated with achievement of high-volume post-dilution hemodiafiltration: Results of an international study" "autores" => array:1 [ 0 => array:2 [ "etal" => true "autores" => array:6 [ 0 => "D. Marcelli" 1 => "P. Kopperschmidt" 2 => "I. Bayh" 3 => "T. Jirka" 4 => "J.I. Merello" 5 => "P. Ponce" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.5301/ijao.5000414" "Revista" => array:6 [ "tituloSerie" => "Int J Artif Organs" "fecha" => "2015" "volumen" => "38" "paginaInicial" => "244" "paginaFinal" => "250" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26080930" "web" => "Medline" ] ] ] ] ] ] ] ] ] ] ] ] "agradecimientos" => array:1 [ 0 => array:4 [ "identificador" => "xack328125" "titulo" => "Agradecimientos" "texto" => "<p id="par0115" class="elsevierStylePara elsevierViewall">Queremos manifestar nuestro agradecimiento a todos los pacientes que han participado, así como a todo el personal de la Sección de Diálisis del Hospital Clínic de Barcelona por su colaboración en este estudio y su entusiasmo.</p>" "vista" => "all" ] ] ] "idiomaDefecto" => "es" "url" => "/02116995/0000003800000001/v1_201801090621/S0211699517300711/v1_201801090621/es/main.assets" "Apartado" => array:4 [ "identificador" => "42448" "tipo" => "SECCION" "en" => array:2 [ "titulo" => "Originales" "idiomaDefecto" => true ] "idiomaDefecto" => "en" ] "PDF" => "https://static.elsevier.es/multimedia/02116995/0000003800000001/v1_201801090621/S0211699517300711/v1_201801090621/es/main.pdf?idApp=UINPBA000064&text.app=https://revistanefrologia.com/" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0211699517300711?idApp=UINPBA000064" ]
año/Mes | Html | Total | |
---|---|---|---|
2024 Noviembre | 16 | 12 | 28 |
2024 Octubre | 125 | 38 | 163 |
2024 Septiembre | 114 | 27 | 141 |
2024 Agosto | 140 | 52 | 192 |
2024 Julio | 112 | 29 | 141 |
2024 Junio | 116 | 45 | 161 |
2024 Mayo | 97 | 41 | 138 |
2024 Abril | 132 | 54 | 186 |
2024 Marzo | 95 | 25 | 120 |
2024 Febrero | 82 | 42 | 124 |
2024 Enero | 75 | 31 | 106 |
2023 Diciembre | 73 | 26 | 99 |
2023 Noviembre | 98 | 39 | 137 |
2023 Octubre | 75 | 43 | 118 |
2023 Septiembre | 88 | 31 | 119 |
2023 Agosto | 86 | 29 | 115 |
2023 Julio | 91 | 32 | 123 |
2023 Junio | 115 | 38 | 153 |
2023 Mayo | 126 | 40 | 166 |
2023 Abril | 97 | 21 | 118 |
2023 Marzo | 111 | 25 | 136 |
2023 Febrero | 104 | 26 | 130 |
2023 Enero | 80 | 39 | 119 |
2022 Diciembre | 100 | 51 | 151 |
2022 Noviembre | 112 | 55 | 167 |
2022 Octubre | 130 | 67 | 197 |
2022 Septiembre | 98 | 53 | 151 |
2022 Agosto | 108 | 61 | 169 |
2022 Julio | 99 | 60 | 159 |
2022 Junio | 106 | 63 | 169 |
2022 Mayo | 106 | 46 | 152 |
2022 Abril | 172 | 66 | 238 |
2022 Marzo | 186 | 65 | 251 |
2022 Febrero | 179 | 65 | 244 |
2022 Enero | 138 | 56 | 194 |
2021 Diciembre | 98 | 54 | 152 |
2021 Noviembre | 115 | 52 | 167 |
2021 Octubre | 106 | 72 | 178 |
2021 Septiembre | 87 | 70 | 157 |
2021 Agosto | 65 | 64 | 129 |
2021 Julio | 86 | 46 | 132 |
2021 Junio | 101 | 41 | 142 |
2021 Mayo | 79 | 61 | 140 |
2021 Abril | 232 | 124 | 356 |
2021 Marzo | 104 | 46 | 150 |
2021 Febrero | 112 | 48 | 160 |
2021 Enero | 78 | 27 | 105 |
2020 Diciembre | 82 | 18 | 100 |
2020 Noviembre | 72 | 30 | 102 |
2020 Octubre | 89 | 37 | 126 |
2020 Septiembre | 99 | 42 | 141 |
2020 Agosto | 79 | 31 | 110 |
2020 Julio | 83 | 17 | 100 |
2020 Junio | 121 | 42 | 163 |
2020 Mayo | 102 | 28 | 130 |
2020 Abril | 72 | 37 | 109 |
2020 Marzo | 69 | 22 | 91 |
2020 Febrero | 86 | 21 | 107 |
2020 Enero | 108 | 34 | 142 |
2019 Diciembre | 108 | 34 | 142 |
2019 Noviembre | 87 | 32 | 119 |
2019 Octubre | 98 | 27 | 125 |
2019 Septiembre | 80 | 23 | 103 |
2019 Agosto | 85 | 32 | 117 |
2019 Julio | 73 | 26 | 99 |
2019 Junio | 68 | 38 | 106 |
2019 Mayo | 70 | 34 | 104 |
2019 Abril | 132 | 68 | 200 |
2019 Marzo | 101 | 54 | 155 |
2019 Febrero | 67 | 42 | 109 |
2019 Enero | 77 | 34 | 111 |
2018 Diciembre | 237 | 59 | 296 |
2018 Noviembre | 471 | 29 | 500 |
2018 Octubre | 435 | 21 | 456 |
2018 Septiembre | 187 | 28 | 215 |
2018 Agosto | 136 | 43 | 179 |
2018 Julio | 86 | 27 | 113 |
2018 Junio | 89 | 18 | 107 |
2018 Mayo | 87 | 23 | 110 |
2018 Abril | 105 | 19 | 124 |
2018 Marzo | 111 | 23 | 134 |
2018 Febrero | 295 | 13 | 308 |
2018 Enero | 154 | 16 | 170 |