In the supplement “Recomendaciones para el trasplante renal de donante vivo” (nefrologia2022;42(S2):1–128) the following errors have been detected:
In the article “Living-donor kidney transplant: guidelines with updated evidence” doi: 10.1016/j.nefroe.2022.01.009
In the article “Living Donor Renal Transplantation: Guideline with updated evidence” (doi: 10.1016/j.nefro.2022.01.007), the following paragraph is replaced: It is recommended to clamp the donors's artery, for greater safety; the use of double Hem-o-loks is recommended, applied with a separation of 2 mm and at the same distance from the section border17.
for this one:
In the clipping of the donor renal artery, the use of hem-o-lok system is not recommended due to the death of a donor in an exceptional way, due to hemorrhage17.
2. 17th bibliographic citation must be substituted by:
S Janki, D Verver, KWJ Klop et al.
Vascular management during live donor nephrectomy: an online survey among transplant surgeons. Am J Transplant. 2015; 15(6):1701-7. doi: 10.1111/ajt.13142.
3. In table 1 the sentence: Renal artery ligation should be performed with a double Hem-o-lok-type clip.
Must be substituted by:
Renal artery ligation should not be performed with a hem-o-lok clip system.