array:19 [
  "pii" => "X0211699500012483"
  "issn" => "02116995"
  "estado" => "S300"
  "fechaPublicacion" => "2000-06-01"
  "documento" => "article"
  "licencia" => "http://www.elsevier.com/open-access/userlicense/1.0/"
  "subdocumento" => "fla"
  "cita" => "Nefrologia. 2000;20:269-76"
  "abierto" => array:3 [
    "ES" => true
    "ES2" => true
    "LATM" => true
  ]
  "gratuito" => true
  "lecturas" => array:2 [
    "total" => 5799
    "formatos" => array:3 [
      "EPUB" => 174
      "HTML" => 4806
      "PDF" => 819
    ]
  ]
  "itemSiguiente" => array:15 [
    "pii" => "X0211699500012475"
    "issn" => "02116995"
    "estado" => "S300"
    "fechaPublicacion" => "2000-06-01"
    "documento" => "article"
    "licencia" => "http://www.elsevier.com/open-access/userlicense/1.0/"
    "subdocumento" => "fla"
    "cita" => "Nefrologia. 2000;20:277-83"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 3562
      "formatos" => array:3 [
        "EPUB" => 180
        "HTML" => 2942
        "PDF" => 440
      ]
    ]
    "es" => array:8 [
      "idiomaDefecto" => true
      "titulo" => "Metodología para evaluar la capacidad de crecimiento ex vivo de las células mesoteliales obtenidas directamente del efluente peritoneal"
      "tienePdf" => "es"
      "tieneTextoCompleto" => "es"
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "277"
          "paginaFinal" => "283"
        ]
      ]
      "contieneTextoCompleto" => array:1 [
        "es" => true
      ]
      "contienePdf" => array:1 [
        "es" => true
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "C. DÍAZ , R. SELGAS , M. A. BAJO , G. DEL PESO , M. A. CASTRO , M. J. SÁNCHEZ-CABEZUDO , M. FERNÁNDEZ DE CASTRO , M. E. MARTÍNEZ"
          "autores" => array:1 [
            0 => array:1 [
              "nombre" => "C. DÍAZ , R. SELGAS , M. A. BAJO , G. DEL PESO , M. A. CASTRO , M. J. SÁNCHEZ-CABEZUDO , M. FERNÁNDEZ DE CASTRO , M. E. MARTÍNEZ"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "es"
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/X0211699500012475?idApp=UINPBA000064"
    "url" => "/02116995/0000002000000003/v0_201502091336/X0211699500012475/v0_201502091336/es/main.assets"
  ]
  "itemAnterior" => array:15 [
    "pii" => "X0211699500012491"
    "issn" => "02116995"
    "estado" => "S300"
    "fechaPublicacion" => "2000-06-01"
    "documento" => "article"
    "licencia" => "http://www.elsevier.com/open-access/userlicense/1.0/"
    "subdocumento" => "fla"
    "cita" => "Nefrologia. 2000;20:262-8"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 4464
      "formatos" => array:3 [
        "EPUB" => 178
        "HTML" => 3680
        "PDF" => 606
      ]
    ]
    "es" => array:8 [
      "idiomaDefecto" => true
      "titulo" => "Vía de la L-arginina-óxido nítrico en la hemodiálisis"
      "tienePdf" => "es"
      "tieneTextoCompleto" => "es"
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "262"
          "paginaFinal" => "268"
        ]
      ]
      "contieneTextoCompleto" => array:1 [
        "es" => true
      ]
      "contienePdf" => array:1 [
        "es" => true
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "J. ESTEBAN , M. ALMARAZ , P. GÓMEZ FERNÁNDEZ , G. VELASCO , V. G. MORENO , D. A. GUILLÉN , C. GARCÍA BARROSO"
          "autores" => array:1 [
            0 => array:1 [
              "nombre" => "J. ESTEBAN , M. ALMARAZ , P. GÓMEZ FERNÁNDEZ , G. VELASCO , V. G. MORENO , D. A. GUILLÉN , C. GARCÍA BARROSO"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "es"
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/X0211699500012491?idApp=UINPBA000064"
    "url" => "/02116995/0000002000000003/v0_201502091336/X0211699500012491/v0_201502091336/es/main.assets"
  ]
  "es" => array:8 [
    "idiomaDefecto" => true
    "titulo" => "Comparación de dializadores en hemodiafiltración en línea"
    "tieneTextoCompleto" => true
    "paginas" => array:1 [
      0 => array:2 [
        "paginaInicial" => "269"
        "paginaFinal" => "276"
      ]
    ]
    "autores" => array:1 [
      0 => array:2 [
        "autoresLista" => "F. MADUELL , C. CALVO , V. NAVARRO , J. HERNÁNDEZ-JARAS"
        "autores" => array:1 [
          0 => array:1 [
            "nombre" => "F. MADUELL , C. CALVO , V. NAVARRO , J. HERNÁNDEZ-JARAS"
          ]
        ]
      ]
    ]
    "textoCompleto" => "NEFROLOGÍA. Vol. XX. Número 3. 2000 Comparación de dializadores en hemodiafiltración en línea F. Maduell, V. Navarro, J. Hernández-Jaras y C. Calvo Servicio de Nefrología. Hospital General de Castellón. Castellón. RESUMEN En la actualidad disponemos de una gran variedad de dializadores de alta permeabilidad cuyas características in vitro parecen similares. La HDF en línea es la modalidad de tratamiento de máximo aprovechamiento de los dializadores gracias a la combinación de difusión con una elevada convección, hasta 12 l/h, limitada por el QB y por la PTM (presión transmembrana). Conscientes de esta amplia oferta de mercado, el objetivo del presente trabajo fue valorar las prestaciones in vivo de distintos dializadores en HDF en línea, para identificar las mejores opciones. Se estudiaron once pacientes, 7 hombres y 4 mujeres. Cada uno recibió 11 sesiones de HDF en línea con monitor 4008B, UF 0,5 l/h, QB 400 ml/min, Qi 100 ml/min o 6 l/h, QD 800 ml/min y Td 60 min. Sólo se varió el dializador: triacetato celulosa 1,9 m2 (Tricea 190G), PMMA de 2,1 m2 (BK-2,1P), PEPA de 1,8 m2 (FLX-18GWS), AN69 de 2,0 m2 (Filtral 20), poliamida de 2,1 m2 (Poliflux 2,1) y polisulfonas de 1,8-2 m2 (HF 80, BS-1,8S, APS-900, Arylane H9, Idemsa 2000) y de 2,4 m2 (HdF 100). Se realizó un seguimiento de la presión arterial (PA), venosa (PV) y PTM. Se determinaron urea, creatinina, fósforo, ácido úrico y 2-m inicial, pre y postfiltro para calcular recirculación, aclaramiento puntual (K) y porcentaje de reducción de los distintos solutos. No se observaron variaciones en la PA, PV ni en la recirculación. La depuración de pequeñas moléculas fue similar excepto en el BK-2,1 y el Hdf 100 que fueron inferior y superior respectivamente. La PTM y la depuración de 2m presentaron diferencias entre los dializadores estudiados: Tricea 190G (PTM 336 mm Hg, K 2-m 79 ml/min y reducción del 44,9%), BK-2,1P (PTM 485, K 102 y 48,3%), FLX-18 GWS (PTM 195, K 140 y 54,6%), Filtral 20 (PTM 245, K 132 y 54,1%), Poliflux 2,1 (PTM 209, K 158 y 56,0%) HF 80 (PTM 208, K 160 y 57,4%), BS-1,8S (PTM 186, K 179 y 59,6%), APS-900 (PTM 174, K 176 y 64,8%), Arylane H9 (PTM 206, K 171 y 59,9%), Idemsa 2000 (PTM 203, K 169 y 60,4%), HDF 100 (PTM 152, K 186 y 64,6%). Conclusiones: De los dializadores evaluados en HDF en línea, el triacetato de celulosa y el PMMA tienen una menor depuración de 2-m y están limitados por la PTM. Las polisulfonas presentan la mayor depuración de 2-m y PTM más bajas, destacando el APS-900 y HDF 100. El AN69, PEPA y poliamida han demostrado ser igualmente útiles aunque con una depuración de 2-m ligeramente inferior. Palabras clave: Coeficiente cribado. Dializador. Eficacia depurativa. HDF en línea. PTM. Recibido: 3-XI-99 En versión definitiva: 7-II-00 Aceptado: 28-III-00 Correspondencia: Dr. Francisco Maduell Canals Servicio de Nefrología Hospital General de Castellón Avda. Benicasim, s/n 12004 Castellón 269 F. MADUELL y cols. ON-LINE HEMODIAFILTRATION: COMPARISON OF ELEVEN DIFFERENT HIGH-FLUX DIALYZERS SUMMARY At present we have a great variety of high-flux dialyzers whose characteristics in vitro seem similar. On-line HDF is a technique which combines diffusion with elevated convection and uses dialysate as replacement fluid. On-line HDF provides the highest clearances for small, medium-sized and large molecules and gives the best performance from the dialyzers. Conscious of this wide choice of dialyzers we evaluated the performance of different dialyzers in renowing small and medium-large molecules. Eleven patients were included in this study, 7 males and 4 females. Every patient received 11 on-line HDF sessions with Fresenius 4008B machine, Qi 100 ml/min or 6 L/h, QB 400 ml/min, QB 800 ml/min, UF 0.5 L/h and Td 60 min. only the dialyzer was changed: 1.9 m2 cellulose triacetate (Tricea 190G), 2.1 m2 poly methyl methacrylate of PMMA (BK-2.1P), 1.8 m2 polyester-polymer Allol or PEPA (FLX-18GWS), 2,05 m2 acrylonitrile (Filtral 20), 2.1 m2 polyamide (Poliflux 2.1) and 1.8-2.4 m2 polysulfones (HF 80, BS-1.8S, APS-900, Arylane H9, Idemsa 2000, HdF 100). Arterial pressure, venous pressure and transmembrane pressure (TMP) were monitored. Plasma, urea, creatinine, phosphate, uric acid and 2m concentrations were measured at the beginning and at the end dialysis from arterial and venous blood lines, and arterial blood line with the slow flow method. Recirculation, dialyzer solutes clearance and solute reduction rates were calculated. No significant differences were found in arterial pressure, venous pressure and recirculation. Small molecule removal was similar except in BK-2.1P and HdF 100 dialyzers which were lower and higher respectively. There were differences in TMP and 2m removal among dialyzers employed. Mean TMP, 2m clearance and 2m reduction ratio were: Tricea 190G (TMP 336 mmHg, 2m K 79 ml/min and 2m reduction ratio 44.9%), BK-2.1P (TMP 485, 2m K 102 and 2mRR 48.3%), FLX-18 GWS (TMP 195, 2m K 140 and 2mRR 54.6%), Filtral 20 (TMP 245, 2m K 132 and 2mRR 54.1%), Poliflux 2.1 (TMP 209, 2m K 158 and 2mRR 56.0%), HF 80 (TMP 208, 2m K 160 and 2mRR 57.4%), BS-1.8S (TMP 186, 2m K 179 and 2mRR 59.6%), APS-900 (TMP 174, 2m K 176 and 2mRR 64.8%), Arylane H9 (TMP 206, 2m K 171 and 2mRR 59.9%), Idemsa 2000 (TMP 203, 2m K 169 and 2mRR 60.4%), HdF 100 (TMP 152, 2m K 186 and 2mRR 64.6%). Conclusions: Of the dialyzers evaluated in on-line HDF, cellulose triacetate and PMMA have a smaller 2m removal and their use is limited by an elevated TMP. The polysulfones provide greater 2m removal with lower TMP, particularly the APS-900 and HdF 100 dialyzers. The acrylonitrile, PEPA and polyamide are intermediate. Key words: Dialyzer. Efficacy. On line HDF. Sieving coefficient. Transmembrane pressure. INTRODUCCIÓN La industria farmacéutica acorde con los avances tecnológicos de los monitores, ha desarrollado y perfeccionado sus dializadores a lo largo de los años. 270 Mayor superficie, mejor disposición geométrica de las fibras capilares, menor espesor de pared, menor diámetro interno de las fibras, mayor tamaño de los poros, etc., con el fin de conseguir una mayor depuración tanto de pequeñas como de medianas- HDF EN LÍNEA grandes moléculas. En la actualidad disponemos de una gran variedad de dializadores de alta permeabilidad cuyas características in vitro parecen similares. Las técnicas de hemodiafiltración (HDF) parecen ofrecernos la forma óptima de tratamiento extracorpóreo en los pacientes en diálisis. Utilizan dializadores biocompatibles de alto flujo, proporcionan el mayor aclaramiento por unidad de superficie tanto para pequeñas, medianas como grandes moléculas combinando los procesos de difusión y convección 1-3. Con la modalidad de HDF en línea se consigue el máximo aprovechamiento de los dializadores gracias a la combinación de difusión con una elevada convección, hasta 12 l/h, sólo limitada por el flujo sanguíneo (QB) y por la presión transmembrana (PTM). Es una técnica segura, bien tolerada y permite un aumento considerable del volumen de convección gracias a su sencillez tecnológica y el bajo coste que representa el utilizar el propio líquido de diálisis como solución de reinfus i ó n 4 - 6. La elección del dializador en técnicas de HDF en línea es importante. El filtro ideal debe acercarse a las siguientes características: alta depuración de moléculas pequeñas&#59; elevado coeficiente de cribado para 2m para conseguir una elevada depuración de moléculas medias-grandes&#59; bajo coeficiente de cribado para la albúmina (pérdida casi nula de albúmina, 66.000 daltons, o moléculas de mayor tamaño)&#59; PTM bajas que no limiten el flujo de infusión (Qi)&#59; poseer un gran poder de atrapamiento de endotoxinas y una buena relación calidad-precio. El objetivo del presente trabajo fue valorar en la modalidad de HDF en línea las prestaciones y comportamiento in vivo de once dializadores de alto flujo, para identificar, entre la amplia oferta de mercado, las mejores opciones de eficacia depurativa y facilidad de uso. PACIENTES Y MÉTODOS Se estudiaron once pacientes, 7 hombres y 4 mujeres, en programa regular de hemodiálisis. Los pacientes se dializaron con monitor 4008B Fresenius adecuado para realizar HDF en línea, baño de diálisis con bicarbonato, flujo de líquido de diálisis (QD) 800 ml/min, QB 400 ml/min, Qi 100 ml/min en forma postdilucional, ultrafiltración constante de 0,5 litros/hora y tiempo de duración de 60 minutos. A cada paciente se le realizaron once sesiones de hemodiálisis en las que únicamente se varió el dializador. Las características y prestaciones in vitro de los dializadores se especifican en las tablas I y II respectivamente. El tiempo de diálisis, al igual que un estudio previo 7, fue de una hora porque permite mantener constantes las condiciones del estudio principalmente el Qi. Tiempos superiores obligarían a disminuir el Qi a lo largo de la sesión por un incremento progresivo de la PTM y los resultados no serían comparables. Se realizó un seguimiento del flujo de sangre efectivo (QBe), de la presión arterial (PA), de la presión venosa (PV) y de la PTM, todos ellos cuantificados por los sensores de presión del propio monitor de diálisis. Mensualmente se calibraron las bombas de sangre y de líquido de diálisis de los monitores utilizados en el estudio. En cada una de las sesiones se determinó la concentración de pequeñas moléculas, urea (60 daltons), creatinina (113 daltons), fósforo (96 daltons) y ácido úrico (168 daltons)&#59; y como marcador de grandes moléculas la beta 2 microglobulina, 2m, (11.818 daltons). Una toma al inicio (CI) (directamente del paciente previa a la conexión) y tres tomas a los 60 minutos: de la línea arterial (CA), de la línea venosa (CV) (una vez ya infundido el líquido de reposición) y una última de la línea arterial tras bajar el QB a 50 ml/min durante un minuto (CP). Tabla I. Características de las fibras de los dializadores Membrana Tricea 190G (Baxter ) BK-2.1P (Toray®) FLX-18GWS (Palex®) Filtral 20 (Hospal®) Poliflux 2.1 (Gambro®) HF 80 (Fresenius®) BS-1.8S (Toray®) APS-900 (Izasa®) Arylane H9 (Hospal®) Idemsa 2000 (Idemsa®) HdF 100 S (Fresenius®) ® Superficie (m2) 1,90 2,10 1,80 2,05 2,10 1,89 1,80 1,80 2,01 2,00 2,40 Espesor (µ) 15 30 30 50 50 40 40 45 50 40 35 Diámetro interno (µ) 200 200 210 250 215 200 200 200 215 200 185 CUF (ml/h/mm Hg) 37 41 47 88 83 55 52 75 98 103 > 60 Triacetato celulosa PMMA PEPA AN69 Poliamida Polisulfona Polisulfona Polisulfona Poliarileter-sulfona Polieter-sulfona Polisulfona 271 F. MADUELL y cols. Tabla II. Características in vitro de los dializadores (QB 300, QD 500, Qi 0-10 ml/min) C. Cribado 2m Tricea 190G (Baxter®) BK-2.1P (Toray®) FLX-18GWS (Palex®) Filtral 20 (Hospal®) Poliflux 2.1 (Gambro®) HF 80 (Fresenius®) BS-1.8S (Toray®) APS-900 (Izasa®) Arylane H9 (Hospal®) Idemsa 2000 (Idemsa®) HdF 100 S (Fresenius®) 0,78 0,55 0,88 0,50 0,63 0,65 0,66 0,87 0,75 0,75 0,80 C. Cribado albúmina < < < < < < < < < < < 0,001 0,01 0,004 0,01 0,01 0,001 0,01 0,004 0,01 0,08 0,001 Aclaram. urea 294 (ml/min) 265 274 252 267 248 273 258 268 264 271 Aclaram. fosfato 245 (ml/min) 210 251 199 240 220 246 213 237 242 240 Aclaram. vit B12 191 (ml/min) 145 206 131 178 155 181 188 182 190 190 Las determinaciones de urea (método de la ureasa/glutamato deshidrogenasa), creatinina (Jaffé cinético), fosfato (método del molibdato amónico), urato (uricasa/peroxidasa) y 2m (inmunoturbimetría de partículas) se realizaron con un autoanalizador ILAB 600 Instrumentation Laboratory, Milan). Se realizaron los siguientes cálculos: 1. Índice de recirculación para los diferentes solutos (método de 2 agujas): R (%) = 100* (CP - CA) / (CP - CV) 2. Aclaramiento puntual del dializador (K) in vivo para cada soluto, corregido para el flujo efectivo y la recirculación: K = (QBe = 0,0085 * R * QBe) * (CA - CV) / CA 3. Porcentaje de reducción para cada soluto según las determinaciones pre y postdiálisis: PR = 100 * (CI - CP) / CI Los resultados se expresan como la media aritmética ± desviación típica. Para el análisis de la significación estadística de parámetros cuantitativos se ha empleado el test de ANOVA (Prueba de Newman-Keuls). Se ha considerado estadísticamente significativa una p < 0,05. RESULTADOS Observamos una buena tolerancia en todas las situaciones del estudio. No hubo reacciones anómalas en la conexión, desconexión ni durante la sesión de HDF. No se observaron variaciones en el QB efectivo, PA, PV ni en la recirculación de urea (tabla III) garantizando un adecuado estado del acceso vascular de los pacientes incluidos en el estudio. La PTM estaba significativamente elevada en los dializadores Tricea 190G y BK-2.1P (fig. 1) y obligó a disminuir el Qi antes de los 60 minutos en algunos pacientes. Asimismo con estos dializadores hubo un mayor número de alarmas por elevación de la PTM. No hubo grandes diferencias en la depuración de pequeñas moléculas. El BK-2.1P presentó un aclaramiento significativamente inferior de urea (p < 0,01), creatinina (p < 0,05) y ácido úrico (p < 0,05) en comparación al resto de los dializadores estudiados&#59; diferencias también observadas en el porcentaje de reducción de urea (p < 0,01), creatinina (p < 0,05), fósforo (p < 0,01) y ácido úrico (p < 0,01). El HdF 100 evidenció una depuración Tabla III. QB efectivo, PA, PV y recirculación urea in vivo de los dializadores QB efectivo (ml/min) Tricea 190G (Baxter®) BK-2.1P (Toray®) FLX-18GWS (Palex®) Filtral 20 (Hospal®) Poliflux 2.1 (Gambro®) HF 80 (Fresenius®) BS-1.8S (Toray®) APS-900 (Izasa®) Arylane H9 (Hospal®) Idemsa 2000 (Idemsa®) HdF 100 S (Fresenius®) 361 362 365 358 368 361 365 359 362 364 361 ± ± ± ± ± ± ± ± ± ± ± 8 5 8 8 8 6 7 9 7 6 6 P. Arterial (mm Hg) 176 165 156 189 158 165 156 178 165 157 169 ± ± ± ± ± ± ± ± ± ± ± 34 25 37 29 32 30 28 24 30 25 24 P. Venosa (mm Hg) 180 180 169 174 163 185 164 189 191 176 186 ± ± ± ± ± ± ± ± ± ± ± 40 18 34 16 29 31 29 24 23 32 32 Recirculación (%) 4,5 5,1 5,9 5,9 4,0 4,2 4,3 5,5 5,4 5,7 4,2 ± ± ± ± ± ± ± ± ± ± ± 3 4 6 4 3 4 4 4 3 7 4 272 HDF EN LÍNEA mm Hg 500 400 336 300 200 100 485 PTM 245 195 209 208 186 174 206 203 152 Fig. 1.--PTM (mm Hg) obtenidas en relación al dializador utilizado (HDF en línea, QB 400 ml/min, QD 800 ml/min y Qi 100 ml/min). de urea, creatinina y ácido úrico superiores al resto de los filtros evaluados (p < 0,01), con una tendencia a una mayor eliminación de fósforo sin al- canzar significación estadística (tablas IV y V y fig. 2). Las diferencias más sobresalientes se dieron en la depuración de la 2m oscilando su aclaramiento entre 70 y 186 ml/min y su porcentaje de reducción entre 44,9 y 64,8% (tablas IV y V y fig. 3). El aclaramiento de 2m (tabla IV) separó estadísticamente los dializadores en cinco grupos que de menor a mayor aclaramiento fueron: a) el Tricea 190G (79 ml/min)&#59; b) el BK-2.1P (102 ml/min), p < 0,01 respecto al anterior&#59; c) el FLX-18 GWS (140 ml/min) y el Filtral 20 (132 ml/min), p < 0,01 respecto a los grupos anteriores&#59; d) el Poliflux 2.1 (158 ml/min), el HF 80 (160 ml/min) y el Idemsa 2000 (169 ml/min), p < 0,01 con respecto a los grupos anteriores&#59; e) el BS-1.8S (174 ml/min), APS-900 (181 ml/min, Arylane H9 (171 ml/min) y HdF 100 (186 ml/min), p < 0,01 respecto a los primeros tres grupos y p < 0,05 respecto al cuarto grupo. El porcentaje de reducción de 2m (tabla V y fig. 3) separó los dializadores evaluados en 4 grupos que ordenados de menor a mayor depuración fueron: a) El Tricea 190G (44,9%) y el BK-2.1P (48,3%)&#59; b) el Idemsa 2000 FLX-18GWS Filtral 20 APS-900 BK-2.1P BS-1.8S Arylane H9 HF 80 Tabla IV. Aclaramientos puntuales in vivo de los dializadores (QB 400, QD 800, Qi 100 ml/min) Aclaramiento Tricea 190G (Baxter®) BK-2.1P (Toray®) FLX-18GWS (Palex®) Filtral 20 (Hospal®) Poliflux 2.1 (Gambro®) HF 80 (Fresenius®) BS-1.8S (Toray®) APS-900 (Izasa®) Arylane H9 (Hospal®) Idemsa 2000 (Idemsa®) HdF 100 S (Fresenius®) Urea (ml/min) 275 257 284 280 304 289 294 282 298 293 309 ± ± ± ± ± ± ± ± ± ± ± 20 22 26 21 17 15 17 15 13 17 14 Creatinina (ml/min) 218 212 225 235 228 232 233 224 226 232 239 ± ± ± ± ± ± ± ± ± ± ± 15 11 20 15 32 23 26 21 29 22 23 Fósforo (ml/min) 192 197 216 196 181 193 221 206 216 217 221 ± ± ± ± ± ± ± ± ± ± ± 28 27 35 15 42 24 22 36 43 25 33 A. Úrico (ml/min) 187 165 196 198 206 196 207 194 199 192 215 ± ± ± ± ± ± ± ± ± ± ± 24 19 29 18 29 20 32 22 33 21 20 2m (ml/min) 79 102 140 132 158 160 174 181 171 169 186 ± ± ± ± ± ± ± ± ± ± ± 16 15 22 21 21 16 19 16 19 17 21 Tabla V. Porcentaje de reducción in vivo de los dializadores (QB 400 ml/min, QD 800 ml/min, Qi 100 ml/min, Td 60 min) Urea (%) Tricea 190G (Baxter ) BK-2.1P (Toray®) FLX-18GWS (Palex®) Filtral 20 (Hospal®) Poliflux 2.1 (Gambro®) HF 80 (Fresenius®) BS-1.8S (Toray®) APS-900 (Izasa®) Arylane H9 (Hospal®) Idemsa 2000 (Idemsa®) HdF 100 S (Fresenius®) ® Tricea 190 G Poliflux 2.1 HdF 100 Creatinina (%) 43,3 40,6 42,6 43,7 41,3 44,5 42,9 45,4 44,3 42,3 48,3 ± ± ± ± ± ± ± ± ± ± ± 6 5 4 5 6 5 6 5 7 6 6 Fósforo (%) 47,5 42,6 49,3 47,5 44,9 46,4 48,3 49,4 49,0 46,9 52,2 ± ± ± ± ± ± ± ± ± ± ± 9 7 4 4 6 3 4 4 6 5 5 Ácido Úrico (%) 50,9 46,0 50,7 52,3 49,7 51,3 50,7 53,9 52,4 50,4 56,1 ± ± ± ± ± ± ± ± ± ± ± 6 6 4 6 7 5 4 6 6 6 6 2m (%) 44,9 48,3 54,6 54,1 56,0 57,4 59,6 64,8 59,9 60,4 64,6 ± ± ± ± ± ± ± ± ± ± ± 7 7 4 4 9 5 5 4 8 4 6 45,5 39,4 44,2 44,6 44,4 45,3 42,2 45,9 45,3 44,1 48,7 ± ± ± ± ± ± ± ± ± ± ± 5 6 4 5 6 4 5 4 4 5 5 273 F. MADUELL y cols. * % Porcentaje Reducción Urea 48,7 49 *p < 0,01 respecto a los demas dializadores 47 45,9 45,3 45,5 45,3 45 44,2 44,6 44,4 44,1 43 42,2 41 * 39,4 39 37 35 Idemsa 2000 FLX-18GWS HF 80 Filtral 20 APS-900 BS-1.8S Arylane H9 BK-2.1P Tricea 190 G Poliflux 2.1 HdF 100 Fig. 2.--Porcentajes de reducción de urea obtenidos en relación al dializador utilizado. N = 11, HDF en línea, QB 400 ml/min, QD 800 ml/min, Td 60 min y Qi 100 ml/min. % 70 65 60 55 50 Porcentaje Reducción Beta2 # ## * ** Grupos dializadores con p < 0,01 entre ellos * 57,4 # 54,6 54,1 5 6 48,3 ** * * * 59,6 64,8 59,9 60,4 ** 64,6 ## 45 44,9 FLX-18GWS Idemsa 2000 HF 80 Filtral 20 APS-900 BS-1.8S Arylane H9 BK-2.1P Tricea 190 G Poliflux 2.1 HdF 100 40 Fig. 3.--Porcentajes de reducción de 2m obtenidos en relación al dializador utilizado. N = 11, HDF en línea, QB 400 ml/min, QD 800 ml/min, Td 60 min y Qi 100 ml/min. FKX-18 GWS (54,6%), el Filtral 20 (54,1%) y el Poliflux 2,1 (56,0%), p < 0,01 respecto al grupo anterior&#59; c) el HF 80 (57,4%), BS-1,8S (59,6%), Arylane H9 (59,9%) y el Idemsa 2000 (60,4%), p < 0,01 respecto al primer grupo y p < 0,05 respecto al segundo&#59; d) el APS-900 (64,8%) y el HdF 100 (64,6%), p < 0,01 respecto a los primeros dos grupos y p < 0,05 respecto al anterior. DISCUSIÓN En un estudio anterior valoramos la influencia del QB y Qi en la modalidad de HDF en línea concluyendo que la depuración de pequeñas moléculas se 274 beneficia del incremento del QB y, en menor proporción, del Qi&#59; mientras que la depuración de grandes moléculas mejora con el incremento del Qi y no está influenciada por las variaciones del QB 7. En el presente estudio se ha valorado la influencia del dializador en la depuración de solutos en esta modalidad de tratamiento. Los estudios in vitro utilizan una solución estándar preparada (no es sangre y por tanto no hay elementos formes) para realizar una medición puntual, independientemente del tiempo, de una serie de solutos (urea, creatinina, fósforo, vitamina B12, insulina y/o 2m) en unas determinadas condiciones (QB 200 ml/min, QD 500 ml/min, UF 0, Qi 0-10 ml/min habitualmente). Se calcula un aclaramiento puntual de cada soluto en función de su concentración al inicio del dializador (CA), a la salida del dializador (CV) y del flujo de sangre (QB). El cálculo del aclaramiento puntual en un estudio in vivo se realiza exactamente igual. Se toma una muestra a la entrada (CA) y a la salida (CV) del dializador a un determinado QB. Hay que considerar que se trabaja con sangre y, por tanto, incluye elementos formes y otras sustancias como las proteínas que disminuyen el volumen capaz de ser depurado además de aumentar la viscosidad. Por tanto, es lógico que los aclaramientos obtenidos in vivo, en las mismas condiciones que in vitro, disminuyan entre un 20-30%. También influye el estado de la FAV que hace que el QB efectivo y la recirculación puedan variar. En este trabajo se han obtenido y calculado los aclaramientos puntuales in vivo corregidos tanto para el QBe como para la recirculación. Otra forma distinta de evaluar la capacidad depurativa es mediante el porcentaje de reducción de solutos. Sólo se realiza en estudios in vivo. Se calcula la diferencia entre la concentración inicial (CI) y la concentración final (CF) en un determinado tiempo. Cualquier tiempo es válido para conocer este parámetro y en este caso se optó por 60 minutos ya que nos permitía mantener constantes las condiciones del estudio (Qi y UF principalmente). Si se hubiera realizado con el tiempo de una sesión habitual, el incremento progresivo de la PTM obligaría a ajustar a la baja el Qi a lo largo de la misma en muchas ocasiones en relación a las características del paciente (hematocrito y formación de la capa proteica) y de los dializadores, por lo que los resultados no serían comparables. El porcentaje de reducción de solutos se mide en el compartimento sanguíneo del paciente e interviene, al igual que en el Kt/V, el volumen de distribución para cada soluto. En un estudio previo 7 observamos como el volumen de distribución para la urea era a los 60 minutos del 42,9% del peso corporal mientras que para HDF EN LÍNEA la 2m era tan sólo el 13,7%. Esto significa que la urea se está extrayendo de un volumen tres veces superior al de la 2m y justifica que el porcentaje de reducción de 2m obtenido sea superior al de la urea a pesar de que su aclaramiento sea inferior. La industria farmacéutica ha desarrollado y perfeccionado sus dializadores ofreciendo en la actualidad una amplia oferta. En este estudio se han valorado diez dializadores sintéticos (polimetilmetacrilato o PMMA, poliester-polímero alloy o PEPA, poliacrilonitrilo, poliamida y polisulfona) y también se ha incluido uno de celulosa modificada (triacetato de celulosa) con un elevado coeficiente de ultrafiltración (CUF 37 ml/h/mm Hg). La HDF en línea es la situación de máximo aprovechamiento de los dializadores de alto flujo gracias a la combinación de difusión con una elevada convección. Las principales limitaciones para conseguir y mantener un buen Qi son el acceso vascular (el Qi debe ser como máximo un tercio del QB) y la PTM. En este estudio hemos observado que los dializadores de triacetato de celulosa y PMMA presentaron una elevada PTM lo que dificultó el desarrollo normal del protocolo y presentaron una menor depuración de 2m. La PTM está condicionada principalmente por el Qi (en este estudio se mantuvo constante a 100 ml/min) y a otros factores como la ultrafiltración (también constante en este estudio), el hematocrito y las proteínas totales (prácticamente constantes ya que cada paciente fue comparado consigo mismo), el tiempo de duración de la sesión (también se mantuvo constante) y por las características de cada dializador que fue el único factor que se modificó. El dializador influye sobre la PTM principalmente por su CUF. En este estudio hemos observado que los dializadores que presentaron PTM excesivas, triacetato de celulosa y PMMA, tenían los CUF más bajos (37 y 41 ml/h/mm Hg respectivamente). Por tanto, a raíz de estos resultados, parece razonable que para trabajar en modalidad de HDF en línea se elija un dializador con un CUF mínimo de 50 ml/h/mm Hg. También hemos observado que el dializador de poliacrilonitrilo, con un CUF de 88 ml/h/mm Hg, presentaba una PTM discretamente más elevada por lo que otros factores distintos al CUF, como el espesor y diámetro interno de las fibras u otras características intrínsecas de cada membrana, pueden influir en la PTM. La vitamina B12 (1.355 D), referencia habitual de los aclaramientos in vitro de moléculas medias, no sirve en los estudios in vivo por su alto grado de unión a las proteínas plasmáticas8. Tampoco se pueden realizar cálculos indirectos propuestos por Leypoldt y cols. 9, basados en las especificaciones in vitro de aclaramiento de vitamina B12 y el Kt/V in vivo de urea, porque en técnicas de HDF en línea la UF es muy superior a 20 ml/min, límite máximo especificado por estos autores. Por tanto, la única forma de valorar y comparar la depuración de medias-grandes moléculas, marcador del beneficio de la elevada convección de esta modalidad de tratamiento, ha sido mediante la 2m. Es interesante observar como los aclaramientos de 2m obtenidos in vivo en nuestro estudio (tabla IV) son en la mayoría de los dializadores similares a los aclaramientos de vitamina B12 obtenidos in vitro por los fabricantes (tabla II), a pesar que la 2m tiene un tamaño nueve veces superior. En las condiciones del estudio hemos observado que el aclaramiento de 2m oscilaba entre 70 y 186 ml/min y el porcentaje de reducción de 2m entre el 45 y el 65% en relación al dializador empleado. El grupo de dializadores de polisulfona presentaron las mejores prestaciones en eficacia depurativa de 2m en HDF en línea. Dos destacaron por encima de las demás, el APS-900 por un elevado coeficiente de cribado para la 2m (0,87) y el HdF 100 por una mayor superficie (2,4 m2) junto con un elevado coeficiente de cribado para la 2m (0,80). Sin embargo, llama la atención que el FLX-18 GWS, con el mayor coeficiente de cribado para la 2m in vitro (0,88) así como el mayor aclaramiento in vitro de vitamina B12, presentó in vivo el octavo aclaramiento y porcentaje de reducción de 2m de los filtros contrastados. Estudios multicéntricos 10-15 sugieren que los dializadores de alto flujo aumentan la supervivencia, disminuyen la amiloidosis de diálisis y juegan un papel importante en la evolución clínica gracias a la mayor depuración de moléculas medias-grandes y a la mejor biocompatibilidad que ofrecen. En la actualidad está en curso un estudio prospectivo y multicéntrico, el estudio HEMO 16-17, que compara la evolución de pacientes dializados con membranas de baja permeabilidad versus membranas de alta permeabilidad. La HDF en línea no sólo utiliza dializadores de alta permeabilidad sino que consigue un óptimo aprovechamiento de los mismos gracias al incremento de la convección 7, 18, lo que potencialmente podría mejorar los efectos beneficiosos de este tipo de dializadores. Concluimos que la elección del dializador para realizar HDF en línea es importante. De los once dializadores evaluados en este estudio destacamos que el triacetato de celulosa y el PMMA tienen una menor depuración de 2m y su uso en HDF en línea están limitados por la elevada PTM&#59; los dializadores de polisulfona presentaron la mayor depuración de 2m, destacando entre las mismas el APS-900 y HdF 275 F. MADUELL y cols. 100. Los dializadores de poliamida, poliacrilonitrilo y PEPA han demostrado ser igualmente útiles en esta modalidad de tratamiento aunque con una depuración de 2m ligeramente inferior. BIBLIOGRAFÍA 1. Wizemann V, Kramer W, Knopp G, Rawer P, Mueller K, Schütterle G: Ultrashort hemodiafiltration: efficiency and hemodynamic tolerance. Clin Nephrol 19: 24-30, 1983. 2. Ronco C: Hemofiltration and hemodiafiltration. In: Bosch JP, Stein JH (ed.). Hemodialysis: high-efficiency treatments. Churchill Livingstone, New York, pp. 119-133, 1993. 3. Baldamus CA, Pollok M: Ultrafiltration and hemofiltration: pratical applications. En: Maher (ed.). Replacement of renal function by dialysis. 3rd ed. Kluwer, Boston pp. 327-339, 1989. 4. Canaud B, Kerr P, Argiles A, Flavier JL, Stec F, Mion C: Is hemodiafiltration the dialysis modality of choice for the next decade? Kidney Int 43: 296-299, 1993. 5. Canaud B, Flavier JL, Argiles A, Stec F, Nguyen QV, Bouloux Ch, Garred LJ, MiIon C: Hemodiafiltration with On-Line production of substitution fluid: Long-term safety and quantitative assessment of efficacy. Contrib Nephrol 108: 12-22, 1994. 6. Maduell F, Pozo C, García H, Sánchez L, Hernández-Jaras J, Albero D, Calvo C, Torregrosa I, Navarro V: Change from conventional haemodiafiltration to on-line haemodiafiltration. Nephrol Dial Transplant 14: 1202-1207, 1999. 7. Maduell F, García H, Hernández-Jaras J, Calvo C, Navarro V&#59; Depuración de solutos en hemodiafiltración en línea. Influencia del flujo de sangre y de infusión. Nefrología 19: 3138, 1999. 8. Chandna SM, Tattersall JE, Nevett G, Tew CJ, O'Sullivan J, Greenwood RN, Farrington K: Low serum vitamin B12 levels in chronic high-flux haemodialysis patients. Nephron 75: 259-263, 1997. 9. Leypoldt JK, Cheung AK, Carroll CE, Stannard DC, Pereira BJG, Agodoa LY, Port FK: Effect of dialysis membranes and middle molecule removal on chronic hemodialysis patient survival. Am J Kidney Dis 33: 349-355, 1999. 10. Hornberger JC, Chernew M, Petersen J, Garber AM: A multivariate analysis of mortality and hospital admissions with high-flux dialysis. J Am Soc Nephrol 3: 1227-1237, 1992. 11. Hakim RM, Held PJ, Stannard DC, Wolfe RA, Port FK, Daugirdas JT, Agodoa L: Effect of the dialysis membrane on mortality of chronic hemodialysis patients. Kidney Int 50: 566570, 1996. 12. Locatelli F, Mastrangelo F, Redaelli B, Ronco C, Marcelli D, La Greca G, Orlandini G and the Italian Cooperative Dialysis Study Group. Effects of different membranes and dialysis technologies on patient treatment tolerance and nutritional parameters. Kidney Int 50: 1293-1302, 1996. 13. Koda Y, Nishi S, Miyazaki S, Haginoshita S, Sakurabayashi T, Suzuki M, Sakai S, Yuasa Y, Hirasawa Y, Nishi T: Switch from conventional to high-flux membrane reduces the risk of carpal tunnel syndrome and mortality of hemodialysis patients. Kidney Int 52: 1096-1101, 1997. 14. Hakim RM: The influence of high-flux biocompatible membrane on carpal tunnel syndrome and mortality. Am J Kidney Dis 32: 338-343, 1998. 15. Bloemberger WE, Hakim RM, Stannard DC, Held PJ, Wolfe RA, Agodoa LYC, Port FK: Relationship of dialysis membrane and cause-specific mortality. Am J Kidney Dis 33: 1-10, 1999. 16. Eknoyan G, Levey AS, Beck GJ, Agodoa LY, Daugirdas JT, Kusec JW, Levin NW, Schulman G: Hemodialysis (HEMO) study: Rationale for selection of interventions. Semin Dial 9: 24-33, 1996. 17. Depner TA, Beck G, Daugirdas JT, Kusec J, Eknoyan G: Lessons from hemodialysis (HEMO) study. An improved measure of the actual hemodialysis dose. Am J Kidney Dis 33: 142149, 1999. 18. Ahrenholz P, Winkler E, Ramlow W, Tiess M, Müller W: Online hemodiafiltration with pre- and postdilution: A comparison of efficacy. Int J Artif Organs 20: 81-90, 1997. 276 "
    "pdfFichero" => "P1-E173-S132-A1958.pdf"
    "tienePdf" => true
  ]
  "idiomaDefecto" => "es"
  "url" => "/02116995/0000002000000003/v0_201502091336/X0211699500012483/v0_201502091336/es/main.assets"
  "Apartado" => array:4 [
    "identificador" => "35393"
    "tipo" => "SECCION"
    "es" => array:2 [
      "titulo" => "Artículos Originales"
      "idiomaDefecto" => true
    ]
    "idiomaDefecto" => "es"
  ]
  "PDF" => "https://static.elsevier.es/multimedia/02116995/0000002000000003/v0_201502091336/X0211699500012483/v0_201502091336/es/P1-E173-S132-A1958.pdf?idApp=UINPBA000064&text.app=https://revistanefrologia.com/"
  "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/X0211699500012483?idApp=UINPBA000064"
]
Compartir
Información de la revista

Estadísticas

Siga este enlace para acceder al texto completo del artículo

Comparación de dializadores en hemodiafiltración en línea
F. MADUELL , C. CALVO , V. NAVARRO , J. HERNÁNDEZ-JARAS
Leído
12225
Veces
se ha leído el artículo
3009
Total PDF
9216
Total HTML
Compartir estadísticas
 array:19 [
  "pii" => "X0211699500012483"
  "issn" => "02116995"
  "estado" => "S300"
  "fechaPublicacion" => "2000-06-01"
  "documento" => "article"
  "licencia" => "http://www.elsevier.com/open-access/userlicense/1.0/"
  "subdocumento" => "fla"
  "cita" => "Nefrologia. 2000;20:269-76"
  "abierto" => array:3 [
    "ES" => true
    "ES2" => true
    "LATM" => true
  ]
  "gratuito" => true
  "lecturas" => array:2 [
    "total" => 5799
    "formatos" => array:3 [
      "EPUB" => 174
      "HTML" => 4806
      "PDF" => 819
    ]
  ]
  "itemSiguiente" => array:15 [
    "pii" => "X0211699500012475"
    "issn" => "02116995"
    "estado" => "S300"
    "fechaPublicacion" => "2000-06-01"
    "documento" => "article"
    "licencia" => "http://www.elsevier.com/open-access/userlicense/1.0/"
    "subdocumento" => "fla"
    "cita" => "Nefrologia. 2000;20:277-83"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 3562
      "formatos" => array:3 [
        "EPUB" => 180
        "HTML" => 2942
        "PDF" => 440
      ]
    ]
    "es" => array:8 [
      "idiomaDefecto" => true
      "titulo" => "Metodología para evaluar la capacidad de crecimiento ex vivo de las células mesoteliales obtenidas directamente del efluente peritoneal"
      "tienePdf" => "es"
      "tieneTextoCompleto" => "es"
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "277"
          "paginaFinal" => "283"
        ]
      ]
      "contieneTextoCompleto" => array:1 [
        "es" => true
      ]
      "contienePdf" => array:1 [
        "es" => true
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "C. DÍAZ , R. SELGAS , M. A. BAJO , G. DEL PESO , M. A. CASTRO , M. J. SÁNCHEZ-CABEZUDO , M. FERNÁNDEZ DE CASTRO , M. E. MARTÍNEZ"
          "autores" => array:1 [
            0 => array:1 [
              "nombre" => "C. DÍAZ , R. SELGAS , M. A. BAJO , G. DEL PESO , M. A. CASTRO , M. J. SÁNCHEZ-CABEZUDO , M. FERNÁNDEZ DE CASTRO , M. E. MARTÍNEZ"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "es"
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/X0211699500012475?idApp=UINPBA000064"
    "url" => "/02116995/0000002000000003/v0_201502091336/X0211699500012475/v0_201502091336/es/main.assets"
  ]
  "itemAnterior" => array:15 [
    "pii" => "X0211699500012491"
    "issn" => "02116995"
    "estado" => "S300"
    "fechaPublicacion" => "2000-06-01"
    "documento" => "article"
    "licencia" => "http://www.elsevier.com/open-access/userlicense/1.0/"
    "subdocumento" => "fla"
    "cita" => "Nefrologia. 2000;20:262-8"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 4464
      "formatos" => array:3 [
        "EPUB" => 178
        "HTML" => 3680
        "PDF" => 606
      ]
    ]
    "es" => array:8 [
      "idiomaDefecto" => true
      "titulo" => "Vía de la L-arginina-óxido nítrico en la hemodiálisis"
      "tienePdf" => "es"
      "tieneTextoCompleto" => "es"
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "262"
          "paginaFinal" => "268"
        ]
      ]
      "contieneTextoCompleto" => array:1 [
        "es" => true
      ]
      "contienePdf" => array:1 [
        "es" => true
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "J. ESTEBAN , M. ALMARAZ , P. GÓMEZ FERNÁNDEZ , G. VELASCO , V. G. MORENO , D. A. GUILLÉN , C. GARCÍA BARROSO"
          "autores" => array:1 [
            0 => array:1 [
              "nombre" => "J. ESTEBAN , M. ALMARAZ , P. GÓMEZ FERNÁNDEZ , G. VELASCO , V. G. MORENO , D. A. GUILLÉN , C. GARCÍA BARROSO"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "es"
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/X0211699500012491?idApp=UINPBA000064"
    "url" => "/02116995/0000002000000003/v0_201502091336/X0211699500012491/v0_201502091336/es/main.assets"
  ]
  "es" => array:8 [
    "idiomaDefecto" => true
    "titulo" => "Comparación de dializadores en hemodiafiltración en línea"
    "tieneTextoCompleto" => true
    "paginas" => array:1 [
      0 => array:2 [
        "paginaInicial" => "269"
        "paginaFinal" => "276"
      ]
    ]
    "autores" => array:1 [
      0 => array:2 [
        "autoresLista" => "F. MADUELL , C. CALVO , V. NAVARRO , J. HERNÁNDEZ-JARAS"
        "autores" => array:1 [
          0 => array:1 [
            "nombre" => "F. MADUELL , C. CALVO , V. NAVARRO , J. HERNÁNDEZ-JARAS"
          ]
        ]
      ]
    ]
    "textoCompleto" => "NEFROLOGÍA. Vol. XX. Número 3. 2000 Comparación de dializadores en hemodiafiltración en línea F. Maduell, V. Navarro, J. Hernández-Jaras y C. Calvo Servicio de Nefrología. Hospital General de Castellón. Castellón. RESUMEN En la actualidad disponemos de una gran variedad de dializadores de alta permeabilidad cuyas características in vitro parecen similares. La HDF en línea es la modalidad de tratamiento de máximo aprovechamiento de los dializadores gracias a la combinación de difusión con una elevada convección, hasta 12 l/h, limitada por el QB y por la PTM (presión transmembrana). Conscientes de esta amplia oferta de mercado, el objetivo del presente trabajo fue valorar las prestaciones in vivo de distintos dializadores en HDF en línea, para identificar las mejores opciones. Se estudiaron once pacientes, 7 hombres y 4 mujeres. Cada uno recibió 11 sesiones de HDF en línea con monitor 4008B, UF 0,5 l/h, QB 400 ml/min, Qi 100 ml/min o 6 l/h, QD 800 ml/min y Td 60 min. Sólo se varió el dializador: triacetato celulosa 1,9 m2 (Tricea 190G), PMMA de 2,1 m2 (BK-2,1P), PEPA de 1,8 m2 (FLX-18GWS), AN69 de 2,0 m2 (Filtral 20), poliamida de 2,1 m2 (Poliflux 2,1) y polisulfonas de 1,8-2 m2 (HF 80, BS-1,8S, APS-900, Arylane H9, Idemsa 2000) y de 2,4 m2 (HdF 100). Se realizó un seguimiento de la presión arterial (PA), venosa (PV) y PTM. Se determinaron urea, creatinina, fósforo, ácido úrico y 2-m inicial, pre y postfiltro para calcular recirculación, aclaramiento puntual (K) y porcentaje de reducción de los distintos solutos. No se observaron variaciones en la PA, PV ni en la recirculación. La depuración de pequeñas moléculas fue similar excepto en el BK-2,1 y el Hdf 100 que fueron inferior y superior respectivamente. La PTM y la depuración de 2m presentaron diferencias entre los dializadores estudiados: Tricea 190G (PTM 336 mm Hg, K 2-m 79 ml/min y reducción del 44,9%), BK-2,1P (PTM 485, K 102 y 48,3%), FLX-18 GWS (PTM 195, K 140 y 54,6%), Filtral 20 (PTM 245, K 132 y 54,1%), Poliflux 2,1 (PTM 209, K 158 y 56,0%) HF 80 (PTM 208, K 160 y 57,4%), BS-1,8S (PTM 186, K 179 y 59,6%), APS-900 (PTM 174, K 176 y 64,8%), Arylane H9 (PTM 206, K 171 y 59,9%), Idemsa 2000 (PTM 203, K 169 y 60,4%), HDF 100 (PTM 152, K 186 y 64,6%). Conclusiones: De los dializadores evaluados en HDF en línea, el triacetato de celulosa y el PMMA tienen una menor depuración de 2-m y están limitados por la PTM. Las polisulfonas presentan la mayor depuración de 2-m y PTM más bajas, destacando el APS-900 y HDF 100. El AN69, PEPA y poliamida han demostrado ser igualmente útiles aunque con una depuración de 2-m ligeramente inferior. Palabras clave: Coeficiente cribado. Dializador. Eficacia depurativa. HDF en línea. PTM. Recibido: 3-XI-99 En versión definitiva: 7-II-00 Aceptado: 28-III-00 Correspondencia: Dr. Francisco Maduell Canals Servicio de Nefrología Hospital General de Castellón Avda. Benicasim, s/n 12004 Castellón 269 F. MADUELL y cols. ON-LINE HEMODIAFILTRATION: COMPARISON OF ELEVEN DIFFERENT HIGH-FLUX DIALYZERS SUMMARY At present we have a great variety of high-flux dialyzers whose characteristics in vitro seem similar. On-line HDF is a technique which combines diffusion with elevated convection and uses dialysate as replacement fluid. On-line HDF provides the highest clearances for small, medium-sized and large molecules and gives the best performance from the dialyzers. Conscious of this wide choice of dialyzers we evaluated the performance of different dialyzers in renowing small and medium-large molecules. Eleven patients were included in this study, 7 males and 4 females. Every patient received 11 on-line HDF sessions with Fresenius 4008B machine, Qi 100 ml/min or 6 L/h, QB 400 ml/min, QB 800 ml/min, UF 0.5 L/h and Td 60 min. only the dialyzer was changed: 1.9 m2 cellulose triacetate (Tricea 190G), 2.1 m2 poly methyl methacrylate of PMMA (BK-2.1P), 1.8 m2 polyester-polymer Allol or PEPA (FLX-18GWS), 2,05 m2 acrylonitrile (Filtral 20), 2.1 m2 polyamide (Poliflux 2.1) and 1.8-2.4 m2 polysulfones (HF 80, BS-1.8S, APS-900, Arylane H9, Idemsa 2000, HdF 100). Arterial pressure, venous pressure and transmembrane pressure (TMP) were monitored. Plasma, urea, creatinine, phosphate, uric acid and 2m concentrations were measured at the beginning and at the end dialysis from arterial and venous blood lines, and arterial blood line with the slow flow method. Recirculation, dialyzer solutes clearance and solute reduction rates were calculated. No significant differences were found in arterial pressure, venous pressure and recirculation. Small molecule removal was similar except in BK-2.1P and HdF 100 dialyzers which were lower and higher respectively. There were differences in TMP and 2m removal among dialyzers employed. Mean TMP, 2m clearance and 2m reduction ratio were: Tricea 190G (TMP 336 mmHg, 2m K 79 ml/min and 2m reduction ratio 44.9%), BK-2.1P (TMP 485, 2m K 102 and 2mRR 48.3%), FLX-18 GWS (TMP 195, 2m K 140 and 2mRR 54.6%), Filtral 20 (TMP 245, 2m K 132 and 2mRR 54.1%), Poliflux 2.1 (TMP 209, 2m K 158 and 2mRR 56.0%), HF 80 (TMP 208, 2m K 160 and 2mRR 57.4%), BS-1.8S (TMP 186, 2m K 179 and 2mRR 59.6%), APS-900 (TMP 174, 2m K 176 and 2mRR 64.8%), Arylane H9 (TMP 206, 2m K 171 and 2mRR 59.9%), Idemsa 2000 (TMP 203, 2m K 169 and 2mRR 60.4%), HdF 100 (TMP 152, 2m K 186 and 2mRR 64.6%). Conclusions: Of the dialyzers evaluated in on-line HDF, cellulose triacetate and PMMA have a smaller 2m removal and their use is limited by an elevated TMP. The polysulfones provide greater 2m removal with lower TMP, particularly the APS-900 and HdF 100 dialyzers. The acrylonitrile, PEPA and polyamide are intermediate. Key words: Dialyzer. Efficacy. On line HDF. Sieving coefficient. Transmembrane pressure. INTRODUCCIÓN La industria farmacéutica acorde con los avances tecnológicos de los monitores, ha desarrollado y perfeccionado sus dializadores a lo largo de los años. 270 Mayor superficie, mejor disposición geométrica de las fibras capilares, menor espesor de pared, menor diámetro interno de las fibras, mayor tamaño de los poros, etc., con el fin de conseguir una mayor depuración tanto de pequeñas como de medianas- HDF EN LÍNEA grandes moléculas. En la actualidad disponemos de una gran variedad de dializadores de alta permeabilidad cuyas características in vitro parecen similares. Las técnicas de hemodiafiltración (HDF) parecen ofrecernos la forma óptima de tratamiento extracorpóreo en los pacientes en diálisis. Utilizan dializadores biocompatibles de alto flujo, proporcionan el mayor aclaramiento por unidad de superficie tanto para pequeñas, medianas como grandes moléculas combinando los procesos de difusión y convección 1-3. Con la modalidad de HDF en línea se consigue el máximo aprovechamiento de los dializadores gracias a la combinación de difusión con una elevada convección, hasta 12 l/h, sólo limitada por el flujo sanguíneo (QB) y por la presión transmembrana (PTM). Es una técnica segura, bien tolerada y permite un aumento considerable del volumen de convección gracias a su sencillez tecnológica y el bajo coste que representa el utilizar el propio líquido de diálisis como solución de reinfus i ó n 4 - 6. La elección del dializador en técnicas de HDF en línea es importante. El filtro ideal debe acercarse a las siguientes características: alta depuración de moléculas pequeñas&#59; elevado coeficiente de cribado para 2m para conseguir una elevada depuración de moléculas medias-grandes&#59; bajo coeficiente de cribado para la albúmina (pérdida casi nula de albúmina, 66.000 daltons, o moléculas de mayor tamaño)&#59; PTM bajas que no limiten el flujo de infusión (Qi)&#59; poseer un gran poder de atrapamiento de endotoxinas y una buena relación calidad-precio. El objetivo del presente trabajo fue valorar en la modalidad de HDF en línea las prestaciones y comportamiento in vivo de once dializadores de alto flujo, para identificar, entre la amplia oferta de mercado, las mejores opciones de eficacia depurativa y facilidad de uso. PACIENTES Y MÉTODOS Se estudiaron once pacientes, 7 hombres y 4 mujeres, en programa regular de hemodiálisis. Los pacientes se dializaron con monitor 4008B Fresenius adecuado para realizar HDF en línea, baño de diálisis con bicarbonato, flujo de líquido de diálisis (QD) 800 ml/min, QB 400 ml/min, Qi 100 ml/min en forma postdilucional, ultrafiltración constante de 0,5 litros/hora y tiempo de duración de 60 minutos. A cada paciente se le realizaron once sesiones de hemodiálisis en las que únicamente se varió el dializador. Las características y prestaciones in vitro de los dializadores se especifican en las tablas I y II respectivamente. El tiempo de diálisis, al igual que un estudio previo 7, fue de una hora porque permite mantener constantes las condiciones del estudio principalmente el Qi. Tiempos superiores obligarían a disminuir el Qi a lo largo de la sesión por un incremento progresivo de la PTM y los resultados no serían comparables. Se realizó un seguimiento del flujo de sangre efectivo (QBe), de la presión arterial (PA), de la presión venosa (PV) y de la PTM, todos ellos cuantificados por los sensores de presión del propio monitor de diálisis. Mensualmente se calibraron las bombas de sangre y de líquido de diálisis de los monitores utilizados en el estudio. En cada una de las sesiones se determinó la concentración de pequeñas moléculas, urea (60 daltons), creatinina (113 daltons), fósforo (96 daltons) y ácido úrico (168 daltons)&#59; y como marcador de grandes moléculas la beta 2 microglobulina, 2m, (11.818 daltons). Una toma al inicio (CI) (directamente del paciente previa a la conexión) y tres tomas a los 60 minutos: de la línea arterial (CA), de la línea venosa (CV) (una vez ya infundido el líquido de reposición) y una última de la línea arterial tras bajar el QB a 50 ml/min durante un minuto (CP). Tabla I. Características de las fibras de los dializadores Membrana Tricea 190G (Baxter ) BK-2.1P (Toray®) FLX-18GWS (Palex®) Filtral 20 (Hospal®) Poliflux 2.1 (Gambro®) HF 80 (Fresenius®) BS-1.8S (Toray®) APS-900 (Izasa®) Arylane H9 (Hospal®) Idemsa 2000 (Idemsa®) HdF 100 S (Fresenius®) ® Superficie (m2) 1,90 2,10 1,80 2,05 2,10 1,89 1,80 1,80 2,01 2,00 2,40 Espesor (µ) 15 30 30 50 50 40 40 45 50 40 35 Diámetro interno (µ) 200 200 210 250 215 200 200 200 215 200 185 CUF (ml/h/mm Hg) 37 41 47 88 83 55 52 75 98 103 > 60 Triacetato celulosa PMMA PEPA AN69 Poliamida Polisulfona Polisulfona Polisulfona Poliarileter-sulfona Polieter-sulfona Polisulfona 271 F. MADUELL y cols. Tabla II. Características in vitro de los dializadores (QB 300, QD 500, Qi 0-10 ml/min) C. Cribado 2m Tricea 190G (Baxter®) BK-2.1P (Toray®) FLX-18GWS (Palex®) Filtral 20 (Hospal®) Poliflux 2.1 (Gambro®) HF 80 (Fresenius®) BS-1.8S (Toray®) APS-900 (Izasa®) Arylane H9 (Hospal®) Idemsa 2000 (Idemsa®) HdF 100 S (Fresenius®) 0,78 0,55 0,88 0,50 0,63 0,65 0,66 0,87 0,75 0,75 0,80 C. Cribado albúmina < < < < < < < < < < < 0,001 0,01 0,004 0,01 0,01 0,001 0,01 0,004 0,01 0,08 0,001 Aclaram. urea 294 (ml/min) 265 274 252 267 248 273 258 268 264 271 Aclaram. fosfato 245 (ml/min) 210 251 199 240 220 246 213 237 242 240 Aclaram. vit B12 191 (ml/min) 145 206 131 178 155 181 188 182 190 190 Las determinaciones de urea (método de la ureasa/glutamato deshidrogenasa), creatinina (Jaffé cinético), fosfato (método del molibdato amónico), urato (uricasa/peroxidasa) y 2m (inmunoturbimetría de partículas) se realizaron con un autoanalizador ILAB 600 Instrumentation Laboratory, Milan). Se realizaron los siguientes cálculos: 1. Índice de recirculación para los diferentes solutos (método de 2 agujas): R (%) = 100* (CP - CA) / (CP - CV) 2. Aclaramiento puntual del dializador (K) in vivo para cada soluto, corregido para el flujo efectivo y la recirculación: K = (QBe = 0,0085 * R * QBe) * (CA - CV) / CA 3. Porcentaje de reducción para cada soluto según las determinaciones pre y postdiálisis: PR = 100 * (CI - CP) / CI Los resultados se expresan como la media aritmética ± desviación típica. Para el análisis de la significación estadística de parámetros cuantitativos se ha empleado el test de ANOVA (Prueba de Newman-Keuls). Se ha considerado estadísticamente significativa una p < 0,05. RESULTADOS Observamos una buena tolerancia en todas las situaciones del estudio. No hubo reacciones anómalas en la conexión, desconexión ni durante la sesión de HDF. No se observaron variaciones en el QB efectivo, PA, PV ni en la recirculación de urea (tabla III) garantizando un adecuado estado del acceso vascular de los pacientes incluidos en el estudio. La PTM estaba significativamente elevada en los dializadores Tricea 190G y BK-2.1P (fig. 1) y obligó a disminuir el Qi antes de los 60 minutos en algunos pacientes. Asimismo con estos dializadores hubo un mayor número de alarmas por elevación de la PTM. No hubo grandes diferencias en la depuración de pequeñas moléculas. El BK-2.1P presentó un aclaramiento significativamente inferior de urea (p < 0,01), creatinina (p < 0,05) y ácido úrico (p < 0,05) en comparación al resto de los dializadores estudiados&#59; diferencias también observadas en el porcentaje de reducción de urea (p < 0,01), creatinina (p < 0,05), fósforo (p < 0,01) y ácido úrico (p < 0,01). El HdF 100 evidenció una depuración Tabla III. QB efectivo, PA, PV y recirculación urea in vivo de los dializadores QB efectivo (ml/min) Tricea 190G (Baxter®) BK-2.1P (Toray®) FLX-18GWS (Palex®) Filtral 20 (Hospal®) Poliflux 2.1 (Gambro®) HF 80 (Fresenius®) BS-1.8S (Toray®) APS-900 (Izasa®) Arylane H9 (Hospal®) Idemsa 2000 (Idemsa®) HdF 100 S (Fresenius®) 361 362 365 358 368 361 365 359 362 364 361 ± ± ± ± ± ± ± ± ± ± ± 8 5 8 8 8 6 7 9 7 6 6 P. Arterial (mm Hg) 176 165 156 189 158 165 156 178 165 157 169 ± ± ± ± ± ± ± ± ± ± ± 34 25 37 29 32 30 28 24 30 25 24 P. Venosa (mm Hg) 180 180 169 174 163 185 164 189 191 176 186 ± ± ± ± ± ± ± ± ± ± ± 40 18 34 16 29 31 29 24 23 32 32 Recirculación (%) 4,5 5,1 5,9 5,9 4,0 4,2 4,3 5,5 5,4 5,7 4,2 ± ± ± ± ± ± ± ± ± ± ± 3 4 6 4 3 4 4 4 3 7 4 272 HDF EN LÍNEA mm Hg 500 400 336 300 200 100 485 PTM 245 195 209 208 186 174 206 203 152 Fig. 1.--PTM (mm Hg) obtenidas en relación al dializador utilizado (HDF en línea, QB 400 ml/min, QD 800 ml/min y Qi 100 ml/min). de urea, creatinina y ácido úrico superiores al resto de los filtros evaluados (p < 0,01), con una tendencia a una mayor eliminación de fósforo sin al- canzar significación estadística (tablas IV y V y fig. 2). Las diferencias más sobresalientes se dieron en la depuración de la 2m oscilando su aclaramiento entre 70 y 186 ml/min y su porcentaje de reducción entre 44,9 y 64,8% (tablas IV y V y fig. 3). El aclaramiento de 2m (tabla IV) separó estadísticamente los dializadores en cinco grupos que de menor a mayor aclaramiento fueron: a) el Tricea 190G (79 ml/min)&#59; b) el BK-2.1P (102 ml/min), p < 0,01 respecto al anterior&#59; c) el FLX-18 GWS (140 ml/min) y el Filtral 20 (132 ml/min), p < 0,01 respecto a los grupos anteriores&#59; d) el Poliflux 2.1 (158 ml/min), el HF 80 (160 ml/min) y el Idemsa 2000 (169 ml/min), p < 0,01 con respecto a los grupos anteriores&#59; e) el BS-1.8S (174 ml/min), APS-900 (181 ml/min, Arylane H9 (171 ml/min) y HdF 100 (186 ml/min), p < 0,01 respecto a los primeros tres grupos y p < 0,05 respecto al cuarto grupo. El porcentaje de reducción de 2m (tabla V y fig. 3) separó los dializadores evaluados en 4 grupos que ordenados de menor a mayor depuración fueron: a) El Tricea 190G (44,9%) y el BK-2.1P (48,3%)&#59; b) el Idemsa 2000 FLX-18GWS Filtral 20 APS-900 BK-2.1P BS-1.8S Arylane H9 HF 80 Tabla IV. Aclaramientos puntuales in vivo de los dializadores (QB 400, QD 800, Qi 100 ml/min) Aclaramiento Tricea 190G (Baxter®) BK-2.1P (Toray®) FLX-18GWS (Palex®) Filtral 20 (Hospal®) Poliflux 2.1 (Gambro®) HF 80 (Fresenius®) BS-1.8S (Toray®) APS-900 (Izasa®) Arylane H9 (Hospal®) Idemsa 2000 (Idemsa®) HdF 100 S (Fresenius®) Urea (ml/min) 275 257 284 280 304 289 294 282 298 293 309 ± ± ± ± ± ± ± ± ± ± ± 20 22 26 21 17 15 17 15 13 17 14 Creatinina (ml/min) 218 212 225 235 228 232 233 224 226 232 239 ± ± ± ± ± ± ± ± ± ± ± 15 11 20 15 32 23 26 21 29 22 23 Fósforo (ml/min) 192 197 216 196 181 193 221 206 216 217 221 ± ± ± ± ± ± ± ± ± ± ± 28 27 35 15 42 24 22 36 43 25 33 A. Úrico (ml/min) 187 165 196 198 206 196 207 194 199 192 215 ± ± ± ± ± ± ± ± ± ± ± 24 19 29 18 29 20 32 22 33 21 20 2m (ml/min) 79 102 140 132 158 160 174 181 171 169 186 ± ± ± ± ± ± ± ± ± ± ± 16 15 22 21 21 16 19 16 19 17 21 Tabla V. Porcentaje de reducción in vivo de los dializadores (QB 400 ml/min, QD 800 ml/min, Qi 100 ml/min, Td 60 min) Urea (%) Tricea 190G (Baxter ) BK-2.1P (Toray®) FLX-18GWS (Palex®) Filtral 20 (Hospal®) Poliflux 2.1 (Gambro®) HF 80 (Fresenius®) BS-1.8S (Toray®) APS-900 (Izasa®) Arylane H9 (Hospal®) Idemsa 2000 (Idemsa®) HdF 100 S (Fresenius®) ® Tricea 190 G Poliflux 2.1 HdF 100 Creatinina (%) 43,3 40,6 42,6 43,7 41,3 44,5 42,9 45,4 44,3 42,3 48,3 ± ± ± ± ± ± ± ± ± ± ± 6 5 4 5 6 5 6 5 7 6 6 Fósforo (%) 47,5 42,6 49,3 47,5 44,9 46,4 48,3 49,4 49,0 46,9 52,2 ± ± ± ± ± ± ± ± ± ± ± 9 7 4 4 6 3 4 4 6 5 5 Ácido Úrico (%) 50,9 46,0 50,7 52,3 49,7 51,3 50,7 53,9 52,4 50,4 56,1 ± ± ± ± ± ± ± ± ± ± ± 6 6 4 6 7 5 4 6 6 6 6 2m (%) 44,9 48,3 54,6 54,1 56,0 57,4 59,6 64,8 59,9 60,4 64,6 ± ± ± ± ± ± ± ± ± ± ± 7 7 4 4 9 5 5 4 8 4 6 45,5 39,4 44,2 44,6 44,4 45,3 42,2 45,9 45,3 44,1 48,7 ± ± ± ± ± ± ± ± ± ± ± 5 6 4 5 6 4 5 4 4 5 5 273 F. MADUELL y cols. * % Porcentaje Reducción Urea 48,7 49 *p < 0,01 respecto a los demas dializadores 47 45,9 45,3 45,5 45,3 45 44,2 44,6 44,4 44,1 43 42,2 41 * 39,4 39 37 35 Idemsa 2000 FLX-18GWS HF 80 Filtral 20 APS-900 BS-1.8S Arylane H9 BK-2.1P Tricea 190 G Poliflux 2.1 HdF 100 Fig. 2.--Porcentajes de reducción de urea obtenidos en relación al dializador utilizado. N = 11, HDF en línea, QB 400 ml/min, QD 800 ml/min, Td 60 min y Qi 100 ml/min. % 70 65 60 55 50 Porcentaje Reducción Beta2 # ## * ** Grupos dializadores con p < 0,01 entre ellos * 57,4 # 54,6 54,1 5 6 48,3 ** * * * 59,6 64,8 59,9 60,4 ** 64,6 ## 45 44,9 FLX-18GWS Idemsa 2000 HF 80 Filtral 20 APS-900 BS-1.8S Arylane H9 BK-2.1P Tricea 190 G Poliflux 2.1 HdF 100 40 Fig. 3.--Porcentajes de reducción de 2m obtenidos en relación al dializador utilizado. N = 11, HDF en línea, QB 400 ml/min, QD 800 ml/min, Td 60 min y Qi 100 ml/min. FKX-18 GWS (54,6%), el Filtral 20 (54,1%) y el Poliflux 2,1 (56,0%), p < 0,01 respecto al grupo anterior&#59; c) el HF 80 (57,4%), BS-1,8S (59,6%), Arylane H9 (59,9%) y el Idemsa 2000 (60,4%), p < 0,01 respecto al primer grupo y p < 0,05 respecto al segundo&#59; d) el APS-900 (64,8%) y el HdF 100 (64,6%), p < 0,01 respecto a los primeros dos grupos y p < 0,05 respecto al anterior. DISCUSIÓN En un estudio anterior valoramos la influencia del QB y Qi en la modalidad de HDF en línea concluyendo que la depuración de pequeñas moléculas se 274 beneficia del incremento del QB y, en menor proporción, del Qi&#59; mientras que la depuración de grandes moléculas mejora con el incremento del Qi y no está influenciada por las variaciones del QB 7. En el presente estudio se ha valorado la influencia del dializador en la depuración de solutos en esta modalidad de tratamiento. Los estudios in vitro utilizan una solución estándar preparada (no es sangre y por tanto no hay elementos formes) para realizar una medición puntual, independientemente del tiempo, de una serie de solutos (urea, creatinina, fósforo, vitamina B12, insulina y/o 2m) en unas determinadas condiciones (QB 200 ml/min, QD 500 ml/min, UF 0, Qi 0-10 ml/min habitualmente). Se calcula un aclaramiento puntual de cada soluto en función de su concentración al inicio del dializador (CA), a la salida del dializador (CV) y del flujo de sangre (QB). El cálculo del aclaramiento puntual en un estudio in vivo se realiza exactamente igual. Se toma una muestra a la entrada (CA) y a la salida (CV) del dializador a un determinado QB. Hay que considerar que se trabaja con sangre y, por tanto, incluye elementos formes y otras sustancias como las proteínas que disminuyen el volumen capaz de ser depurado además de aumentar la viscosidad. Por tanto, es lógico que los aclaramientos obtenidos in vivo, en las mismas condiciones que in vitro, disminuyan entre un 20-30%. También influye el estado de la FAV que hace que el QB efectivo y la recirculación puedan variar. En este trabajo se han obtenido y calculado los aclaramientos puntuales in vivo corregidos tanto para el QBe como para la recirculación. Otra forma distinta de evaluar la capacidad depurativa es mediante el porcentaje de reducción de solutos. Sólo se realiza en estudios in vivo. Se calcula la diferencia entre la concentración inicial (CI) y la concentración final (CF) en un determinado tiempo. Cualquier tiempo es válido para conocer este parámetro y en este caso se optó por 60 minutos ya que nos permitía mantener constantes las condiciones del estudio (Qi y UF principalmente). Si se hubiera realizado con el tiempo de una sesión habitual, el incremento progresivo de la PTM obligaría a ajustar a la baja el Qi a lo largo de la misma en muchas ocasiones en relación a las características del paciente (hematocrito y formación de la capa proteica) y de los dializadores, por lo que los resultados no serían comparables. El porcentaje de reducción de solutos se mide en el compartimento sanguíneo del paciente e interviene, al igual que en el Kt/V, el volumen de distribución para cada soluto. En un estudio previo 7 observamos como el volumen de distribución para la urea era a los 60 minutos del 42,9% del peso corporal mientras que para HDF EN LÍNEA la 2m era tan sólo el 13,7%. Esto significa que la urea se está extrayendo de un volumen tres veces superior al de la 2m y justifica que el porcentaje de reducción de 2m obtenido sea superior al de la urea a pesar de que su aclaramiento sea inferior. La industria farmacéutica ha desarrollado y perfeccionado sus dializadores ofreciendo en la actualidad una amplia oferta. En este estudio se han valorado diez dializadores sintéticos (polimetilmetacrilato o PMMA, poliester-polímero alloy o PEPA, poliacrilonitrilo, poliamida y polisulfona) y también se ha incluido uno de celulosa modificada (triacetato de celulosa) con un elevado coeficiente de ultrafiltración (CUF 37 ml/h/mm Hg). La HDF en línea es la situación de máximo aprovechamiento de los dializadores de alto flujo gracias a la combinación de difusión con una elevada convección. Las principales limitaciones para conseguir y mantener un buen Qi son el acceso vascular (el Qi debe ser como máximo un tercio del QB) y la PTM. En este estudio hemos observado que los dializadores de triacetato de celulosa y PMMA presentaron una elevada PTM lo que dificultó el desarrollo normal del protocolo y presentaron una menor depuración de 2m. La PTM está condicionada principalmente por el Qi (en este estudio se mantuvo constante a 100 ml/min) y a otros factores como la ultrafiltración (también constante en este estudio), el hematocrito y las proteínas totales (prácticamente constantes ya que cada paciente fue comparado consigo mismo), el tiempo de duración de la sesión (también se mantuvo constante) y por las características de cada dializador que fue el único factor que se modificó. El dializador influye sobre la PTM principalmente por su CUF. En este estudio hemos observado que los dializadores que presentaron PTM excesivas, triacetato de celulosa y PMMA, tenían los CUF más bajos (37 y 41 ml/h/mm Hg respectivamente). Por tanto, a raíz de estos resultados, parece razonable que para trabajar en modalidad de HDF en línea se elija un dializador con un CUF mínimo de 50 ml/h/mm Hg. También hemos observado que el dializador de poliacrilonitrilo, con un CUF de 88 ml/h/mm Hg, presentaba una PTM discretamente más elevada por lo que otros factores distintos al CUF, como el espesor y diámetro interno de las fibras u otras características intrínsecas de cada membrana, pueden influir en la PTM. La vitamina B12 (1.355 D), referencia habitual de los aclaramientos in vitro de moléculas medias, no sirve en los estudios in vivo por su alto grado de unión a las proteínas plasmáticas8. Tampoco se pueden realizar cálculos indirectos propuestos por Leypoldt y cols. 9, basados en las especificaciones in vitro de aclaramiento de vitamina B12 y el Kt/V in vivo de urea, porque en técnicas de HDF en línea la UF es muy superior a 20 ml/min, límite máximo especificado por estos autores. Por tanto, la única forma de valorar y comparar la depuración de medias-grandes moléculas, marcador del beneficio de la elevada convección de esta modalidad de tratamiento, ha sido mediante la 2m. Es interesante observar como los aclaramientos de 2m obtenidos in vivo en nuestro estudio (tabla IV) son en la mayoría de los dializadores similares a los aclaramientos de vitamina B12 obtenidos in vitro por los fabricantes (tabla II), a pesar que la 2m tiene un tamaño nueve veces superior. En las condiciones del estudio hemos observado que el aclaramiento de 2m oscilaba entre 70 y 186 ml/min y el porcentaje de reducción de 2m entre el 45 y el 65% en relación al dializador empleado. El grupo de dializadores de polisulfona presentaron las mejores prestaciones en eficacia depurativa de 2m en HDF en línea. Dos destacaron por encima de las demás, el APS-900 por un elevado coeficiente de cribado para la 2m (0,87) y el HdF 100 por una mayor superficie (2,4 m2) junto con un elevado coeficiente de cribado para la 2m (0,80). Sin embargo, llama la atención que el FLX-18 GWS, con el mayor coeficiente de cribado para la 2m in vitro (0,88) así como el mayor aclaramiento in vitro de vitamina B12, presentó in vivo el octavo aclaramiento y porcentaje de reducción de 2m de los filtros contrastados. Estudios multicéntricos 10-15 sugieren que los dializadores de alto flujo aumentan la supervivencia, disminuyen la amiloidosis de diálisis y juegan un papel importante en la evolución clínica gracias a la mayor depuración de moléculas medias-grandes y a la mejor biocompatibilidad que ofrecen. En la actualidad está en curso un estudio prospectivo y multicéntrico, el estudio HEMO 16-17, que compara la evolución de pacientes dializados con membranas de baja permeabilidad versus membranas de alta permeabilidad. La HDF en línea no sólo utiliza dializadores de alta permeabilidad sino que consigue un óptimo aprovechamiento de los mismos gracias al incremento de la convección 7, 18, lo que potencialmente podría mejorar los efectos beneficiosos de este tipo de dializadores. Concluimos que la elección del dializador para realizar HDF en línea es importante. De los once dializadores evaluados en este estudio destacamos que el triacetato de celulosa y el PMMA tienen una menor depuración de 2m y su uso en HDF en línea están limitados por la elevada PTM&#59; los dializadores de polisulfona presentaron la mayor depuración de 2m, destacando entre las mismas el APS-900 y HdF 275 F. MADUELL y cols. 100. Los dializadores de poliamida, poliacrilonitrilo y PEPA han demostrado ser igualmente útiles en esta modalidad de tratamiento aunque con una depuración de 2m ligeramente inferior. BIBLIOGRAFÍA 1. Wizemann V, Kramer W, Knopp G, Rawer P, Mueller K, Schütterle G: Ultrashort hemodiafiltration: efficiency and hemodynamic tolerance. Clin Nephrol 19: 24-30, 1983. 2. Ronco C: Hemofiltration and hemodiafiltration. In: Bosch JP, Stein JH (ed.). Hemodialysis: high-efficiency treatments. Churchill Livingstone, New York, pp. 119-133, 1993. 3. Baldamus CA, Pollok M: Ultrafiltration and hemofiltration: pratical applications. En: Maher (ed.). Replacement of renal function by dialysis. 3rd ed. Kluwer, Boston pp. 327-339, 1989. 4. Canaud B, Kerr P, Argiles A, Flavier JL, Stec F, Mion C: Is hemodiafiltration the dialysis modality of choice for the next decade? Kidney Int 43: 296-299, 1993. 5. Canaud B, Flavier JL, Argiles A, Stec F, Nguyen QV, Bouloux Ch, Garred LJ, MiIon C: Hemodiafiltration with On-Line production of substitution fluid: Long-term safety and quantitative assessment of efficacy. Contrib Nephrol 108: 12-22, 1994. 6. Maduell F, Pozo C, García H, Sánchez L, Hernández-Jaras J, Albero D, Calvo C, Torregrosa I, Navarro V: Change from conventional haemodiafiltration to on-line haemodiafiltration. Nephrol Dial Transplant 14: 1202-1207, 1999. 7. Maduell F, García H, Hernández-Jaras J, Calvo C, Navarro V&#59; Depuración de solutos en hemodiafiltración en línea. Influencia del flujo de sangre y de infusión. Nefrología 19: 3138, 1999. 8. Chandna SM, Tattersall JE, Nevett G, Tew CJ, O'Sullivan J, Greenwood RN, Farrington K: Low serum vitamin B12 levels in chronic high-flux haemodialysis patients. Nephron 75: 259-263, 1997. 9. Leypoldt JK, Cheung AK, Carroll CE, Stannard DC, Pereira BJG, Agodoa LY, Port FK: Effect of dialysis membranes and middle molecule removal on chronic hemodialysis patient survival. Am J Kidney Dis 33: 349-355, 1999. 10. Hornberger JC, Chernew M, Petersen J, Garber AM: A multivariate analysis of mortality and hospital admissions with high-flux dialysis. J Am Soc Nephrol 3: 1227-1237, 1992. 11. Hakim RM, Held PJ, Stannard DC, Wolfe RA, Port FK, Daugirdas JT, Agodoa L: Effect of the dialysis membrane on mortality of chronic hemodialysis patients. Kidney Int 50: 566570, 1996. 12. Locatelli F, Mastrangelo F, Redaelli B, Ronco C, Marcelli D, La Greca G, Orlandini G and the Italian Cooperative Dialysis Study Group. Effects of different membranes and dialysis technologies on patient treatment tolerance and nutritional parameters. Kidney Int 50: 1293-1302, 1996. 13. Koda Y, Nishi S, Miyazaki S, Haginoshita S, Sakurabayashi T, Suzuki M, Sakai S, Yuasa Y, Hirasawa Y, Nishi T: Switch from conventional to high-flux membrane reduces the risk of carpal tunnel syndrome and mortality of hemodialysis patients. Kidney Int 52: 1096-1101, 1997. 14. Hakim RM: The influence of high-flux biocompatible membrane on carpal tunnel syndrome and mortality. Am J Kidney Dis 32: 338-343, 1998. 15. Bloemberger WE, Hakim RM, Stannard DC, Held PJ, Wolfe RA, Agodoa LYC, Port FK: Relationship of dialysis membrane and cause-specific mortality. Am J Kidney Dis 33: 1-10, 1999. 16. Eknoyan G, Levey AS, Beck GJ, Agodoa LY, Daugirdas JT, Kusec JW, Levin NW, Schulman G: Hemodialysis (HEMO) study: Rationale for selection of interventions. Semin Dial 9: 24-33, 1996. 17. Depner TA, Beck G, Daugirdas JT, Kusec J, Eknoyan G: Lessons from hemodialysis (HEMO) study. An improved measure of the actual hemodialysis dose. Am J Kidney Dis 33: 142149, 1999. 18. Ahrenholz P, Winkler E, Ramlow W, Tiess M, Müller W: Online hemodiafiltration with pre- and postdilution: A comparison of efficacy. Int J Artif Organs 20: 81-90, 1997. 276 "
    "pdfFichero" => "P1-E173-S132-A1958.pdf"
    "tienePdf" => true
  ]
  "idiomaDefecto" => "es"
  "url" => "/02116995/0000002000000003/v0_201502091336/X0211699500012483/v0_201502091336/es/main.assets"
  "Apartado" => array:4 [
    "identificador" => "35393"
    "tipo" => "SECCION"
    "es" => array:2 [
      "titulo" => "Artículos Originales"
      "idiomaDefecto" => true
    ]
    "idiomaDefecto" => "es"
  ]
  "PDF" => "https://static.elsevier.es/multimedia/02116995/0000002000000003/v0_201502091336/X0211699500012483/v0_201502091336/es/P1-E173-S132-A1958.pdf?idApp=UINPBA000064&text.app=https://revistanefrologia.com/"
  "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/X0211699500012483?idApp=UINPBA000064"
]
Información del artículo
ISSN: 02116995
Idioma original: Español
Datos actualizados diariamente
año/Mes Html Pdf Total
2024 Noviembre 6 12 18
2024 Octubre 106 44 150
2024 Septiembre 80 45 125
2024 Agosto 92 86 178
2024 Julio 74 38 112
2024 Junio 85 47 132
2024 Mayo 105 47 152
2024 Abril 108 37 145
2024 Marzo 66 31 97
2024 Febrero 77 43 120
2024 Enero 92 38 130
2023 Diciembre 73 31 104
2023 Noviembre 71 38 109
2023 Octubre 88 44 132
2023 Septiembre 84 45 129
2023 Agosto 79 29 108
2023 Julio 75 48 123
2023 Junio 76 38 114
2023 Mayo 68 35 103
2023 Abril 64 45 109
2023 Marzo 72 31 103
2023 Febrero 59 28 87
2023 Enero 69 25 94
2022 Diciembre 51 29 80
2022 Noviembre 51 27 78
2022 Octubre 50 37 87
2022 Septiembre 68 37 105
2022 Agosto 53 37 90
2022 Julio 64 50 114
2022 Junio 43 28 71
2022 Mayo 62 35 97
2022 Abril 67 55 122
2022 Marzo 58 52 110
2022 Febrero 58 48 106
2022 Enero 61 37 98
2021 Diciembre 51 49 100
2021 Noviembre 48 39 87
2021 Octubre 75 41 116
2021 Septiembre 63 49 112
2021 Agosto 82 45 127
2021 Julio 76 33 109
2021 Junio 91 43 134
2021 Mayo 67 38 105
2021 Abril 263 90 353
2021 Marzo 125 48 173
2021 Febrero 67 39 106
2021 Enero 56 25 81
2020 Diciembre 72 29 101
2020 Noviembre 107 35 142
2020 Octubre 85 16 101
2020 Septiembre 79 11 90
2020 Agosto 63 21 84
2020 Julio 61 19 80
2020 Junio 94 36 130
2020 Mayo 95 39 134
2020 Abril 100 24 124
2020 Marzo 94 29 123
2020 Febrero 99 24 123
2020 Enero 81 28 109
2019 Diciembre 74 22 96
2019 Noviembre 105 32 137
2019 Octubre 107 25 132
2019 Septiembre 100 40 140
2019 Agosto 83 20 103
2019 Julio 68 28 96
2019 Junio 85 23 108
2019 Mayo 91 28 119
2019 Abril 135 45 180
2019 Marzo 146 22 168
2019 Febrero 101 21 122
2019 Enero 54 15 69
2018 Diciembre 66 27 93
2018 Noviembre 50 18 68
2018 Octubre 65 29 94
2018 Septiembre 55 29 84
2018 Agosto 49 25 74
2018 Julio 45 20 65
2018 Junio 38 19 57
2018 Mayo 53 14 67
2018 Abril 66 15 81
2018 Marzo 47 8 55
2018 Febrero 50 10 60
2018 Enero 29 9 38
2017 Diciembre 32 8 40
2017 Noviembre 41 18 59
2017 Octubre 51 3 54
2017 Septiembre 41 15 56
2017 Agosto 47 6 53
2017 Julio 33 5 38
2017 Junio 34 22 56
2017 Mayo 41 10 51
2017 Abril 52 9 61
2017 Marzo 75 17 92
2017 Febrero 227 12 239
2017 Enero 45 16 61
2016 Diciembre 69 6 75
2016 Noviembre 85 25 110
2016 Octubre 88 18 106
2016 Septiembre 169 13 182
2016 Agosto 217 16 233
2016 Julio 170 19 189
2016 Junio 119 0 119
2016 Mayo 122 0 122
2016 Abril 110 0 110
2016 Marzo 91 0 91
2016 Febrero 134 0 134
2016 Enero 146 0 146
2015 Diciembre 101 0 101
2015 Noviembre 87 0 87
2015 Octubre 93 0 93
2015 Septiembre 77 0 77
2015 Agosto 75 0 75
2015 Julio 83 0 83
2015 Junio 66 0 66
2015 Mayo 70 0 70
2015 Abril 8 0 8
2015 Febrero 6 0 6
Mostrar todo

Siga este enlace para acceder al texto completo del artículo

Idiomas
Nefrología
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?