array:25 [
  "pii" => "S0211699517301777"
  "issn" => "02116995"
  "doi" => "10.1016/j.nefro.2017.08.003"
  "estado" => "S300"
  "fechaPublicacion" => "2018-01-01"
  "aid" => "416"
  "copyright" => "Sociedad Española de Nefrología"
  "copyrightAnyo" => "2017"
  "documento" => "article"
  "crossmark" => 0
  "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
  "subdocumento" => "sco"
  "cita" => "Nefrologia. 2018;38:4-7"
  "abierto" => array:3 [
    "ES" => true
    "ES2" => true
    "LATM" => true
  ]
  "gratuito" => true
  "lecturas" => array:2 [
    "total" => 13545
    "formatos" => array:3 [
      "EPUB" => 289
      "HTML" => 11745
      "PDF" => 1511
    ]
  ]
  "Traduccion" => array:1 [
    "en" => array:20 [
      "pii" => "S201325141830018X"
      "issn" => "20132514"
      "doi" => "10.1016/j.nefroe.2018.01.006"
      "estado" => "S300"
      "fechaPublicacion" => "2018-01-01"
      "aid" => "416"
      "copyright" => "Sociedad Española de Nefrología"
      "documento" => "article"
      "crossmark" => 0
      "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
      "subdocumento" => "sco"
      "cita" => "Nefrologia (English Version). 2018;38:4-7"
      "abierto" => array:3 [
        "ES" => true
        "ES2" => true
        "LATM" => true
      ]
      "gratuito" => true
      "lecturas" => array:2 [
        "total" => 8679
        "formatos" => array:3 [
          "EPUB" => 259
          "HTML" => 7235
          "PDF" => 1185
        ]
      ]
      "en" => array:11 [
        "idiomaDefecto" => true
        "cabecera" => "<span class="elsevierStyleTextfn">Editorial</span>"
        "titulo" => "The dialyser in the year 2017&#58; Much more than a membrane"
        "tienePdf" => "en"
        "tieneTextoCompleto" => "en"
        "paginas" => array:1 [
          0 => array:2 [
            "paginaInicial" => "4"
            "paginaFinal" => "7"
          ]
        ]
        "titulosAlternativos" => array:1 [
          "es" => array:1 [
            "titulo" => "El dializador en el a&#241;o 2017&#58; mucho m&#225;s que una membrana"
          ]
        ]
        "contieneTextoCompleto" => array:1 [
          "en" => true
        ]
        "contienePdf" => array:1 [
          "en" => true
        ]
        "resumenGrafico" => array:2 [
          "original" => 0
          "multimedia" => array:7 [
            "identificador" => "fig0005"
            "etiqueta" => "Fig&#46; 1"
            "tipo" => "MULTIMEDIAFIGURA"
            "mostrarFloat" => true
            "mostrarDisplay" => false
            "figura" => array:1 [
              0 => array:4 [
                "imagen" => "gr1.jpeg"
                "Alto" => 1061
                "Ancho" => 1500
                "Tamanyo" => 145186
              ]
            ]
            "descripcion" => array:1 [
              "en" => "<p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">Size and distribution of membrane pores&#46;</p> <p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">HCO&#58; high cut-off membranes&#59; HF&#58; high-flux plasma filters and dialysers&#59; MCO&#58; medium cut-off membranes&#47;intermediate pores&#59; s&#47;n&#58; standardised number of pores per each size&#44; out of one&#46;</p>"
            ]
          ]
        ]
        "autores" => array:1 [
          0 => array:2 [
            "autoresLista" => "Rafael P&#233;rez-Garc&#237;a, Roberto Alc&#225;zar"
            "autores" => array:2 [
              0 => array:2 [
                "nombre" => "Rafael"
                "apellidos" => "P&#233;rez-Garc&#237;a"
              ]
              1 => array:2 [
                "nombre" => "Roberto"
                "apellidos" => "Alc&#225;zar"
              ]
            ]
          ]
        ]
      ]
      "idiomaDefecto" => "en"
      "Traduccion" => array:1 [
        "es" => array:9 [
          "pii" => "S0211699517301777"
          "doi" => "10.1016/j.nefro.2017.08.003"
          "estado" => "S300"
          "subdocumento" => ""
          "abierto" => array:3 [
            "ES" => true
            "ES2" => true
            "LATM" => true
          ]
          "gratuito" => true
          "lecturas" => array:1 [
            "total" => 0
          ]
          "idiomaDefecto" => "es"
          "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0211699517301777?idApp=UINPBA000064"
        ]
      ]
      "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S201325141830018X?idApp=UINPBA000064"
      "url" => "/20132514/0000003800000001/v1_201802180616/S201325141830018X/v1_201802180616/en/main.assets"
    ]
  ]
  "itemSiguiente" => array:20 [
    "pii" => "S0211699517301881"
    "issn" => "02116995"
    "doi" => "10.1016/j.nefro.2017.09.004"
    "estado" => "S300"
    "fechaPublicacion" => "2018-01-01"
    "aid" => "426"
    "copyright" => "Sociedad Espa&#241;ola de Nefrolog&#237;a"
    "documento" => "article"
    "crossmark" => 0
    "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
    "subdocumento" => "fla"
    "cita" => "Nefrologia. 2018;38:8-12"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 73975
      "formatos" => array:3 [
        "EPUB" => 441
        "HTML" => 64075
        "PDF" => 9459
      ]
    ]
    "es" => array:13 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Art&#237;culo especial</span>"
      "titulo" => "Anemia en la enfermedad renal cr&#243;nica&#58; protocolo de estudio&#44; manejo y derivaci&#243;n a Nefrolog&#237;a"
      "tienePdf" => "es"
      "tieneTextoCompleto" => "es"
      "tieneResumen" => array:2 [
        0 => "es"
        1 => "en"
      ]
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "8"
          "paginaFinal" => "12"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "en" => array:1 [
          "titulo" => "Anemia of chronic kidney disease&#58; Protocol of study&#44; management and referral to Nephrology"
        ]
      ]
      "contieneResumen" => array:2 [
        "es" => true
        "en" => true
      ]
      "contieneTextoCompleto" => array:1 [
        "es" => true
      ]
      "contienePdf" => array:1 [
        "es" => true
      ]
      "resumenGrafico" => array:2 [
        "original" => 0
        "multimedia" => array:7 [
          "identificador" => "fig0005"
          "etiqueta" => "Figura 1"
          "tipo" => "MULTIMEDIAFIGURA"
          "mostrarFloat" => true
          "mostrarDisplay" => false
          "figura" => array:1 [
            0 => array:4 [
              "imagen" => "gr1.jpeg"
              "Alto" => 1919
              "Ancho" => 2531
              "Tamanyo" => 422101
            ]
          ]
          "descripcion" => array:1 [
            "es" => "<p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">Algoritmo de estudio y remisi&#243;n a Nefrolog&#237;a por anemia de origen renal&#46;</p>"
          ]
        ]
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "Aleix Cases, M&#46; Isabel Egocheaga, Salvador Tranche, Vicente Pallar&#233;s, Raquel Ojeda, Jos&#233; Luis G&#243;rriz, Jos&#233; Mar&#237;a Portol&#233;s"
          "autores" => array:7 [
            0 => array:2 [
              "nombre" => "Aleix"
              "apellidos" => "Cases"
            ]
            1 => array:2 [
              "nombre" => "M&#46; Isabel"
              "apellidos" => "Egocheaga"
            ]
            2 => array:2 [
              "nombre" => "Salvador"
              "apellidos" => "Tranche"
            ]
            3 => array:2 [
              "nombre" => "Vicente"
              "apellidos" => "Pallar&#233;s"
            ]
            4 => array:2 [
              "nombre" => "Raquel"
              "apellidos" => "Ojeda"
            ]
            5 => array:2 [
              "nombre" => "Jos&#233; Luis"
              "apellidos" => "G&#243;rriz"
            ]
            6 => array:2 [
              "nombre" => "Jos&#233; Mar&#237;a"
              "apellidos" => "Portol&#233;s"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "es"
    "Traduccion" => array:1 [
      "en" => array:9 [
        "pii" => "S2013251418300191"
        "doi" => "10.1016/j.nefroe.2018.01.007"
        "estado" => "S300"
        "subdocumento" => ""
        "abierto" => array:3 [
          "ES" => true
          "ES2" => true
          "LATM" => true
        ]
        "gratuito" => true
        "lecturas" => array:1 [
          "total" => 0
        ]
        "idiomaDefecto" => "en"
        "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2013251418300191?idApp=UINPBA000064"
      ]
    ]
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0211699517301881?idApp=UINPBA000064"
    "url" => "/02116995/0000003800000001/v1_201801090621/S0211699517301881/v1_201801090621/es/main.assets"
  ]
  "itemAnterior" => array:20 [
    "pii" => "S021169951730142X"
    "issn" => "02116995"
    "doi" => "10.1016/j.nefro.2017.06.005"
    "estado" => "S300"
    "fechaPublicacion" => "2018-01-01"
    "aid" => "407"
    "copyright" => "Sociedad Espa&#241;ola de Nefrolog&#237;a"
    "documento" => "article"
    "crossmark" => 0
    "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
    "subdocumento" => "sco"
    "cita" => "Nefrologia. 2018;38:1-3"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 8556
      "formatos" => array:3 [
        "EPUB" => 361
        "HTML" => 7086
        "PDF" => 1109
      ]
    ]
    "es" => array:10 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Editorial</span>"
      "titulo" => "Seguridad en hemodi&#225;lisis&#58; paradigma del trabajo en equipo"
      "tienePdf" => "es"
      "tieneTextoCompleto" => "es"
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "1"
          "paginaFinal" => "3"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "en" => array:1 [
          "titulo" => "Safety on haemodialysis&#58; Team work paradigm"
        ]
      ]
      "contieneTextoCompleto" => array:1 [
        "es" => true
      ]
      "contienePdf" => array:1 [
        "es" => true
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "M&#46; Dolores Arenas Jim&#233;nez, Manuel Mac&#237;a-Heras"
          "autores" => array:2 [
            0 => array:2 [
              "nombre" => "M&#46; Dolores"
              "apellidos" => "Arenas Jim&#233;nez"
            ]
            1 => array:2 [
              "nombre" => "Manuel"
              "apellidos" => "Mac&#237;a-Heras"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "es"
    "Traduccion" => array:1 [
      "en" => array:9 [
        "pii" => "S2013251418300178"
        "doi" => "10.1016/j.nefroe.2018.01.005"
        "estado" => "S300"
        "subdocumento" => ""
        "abierto" => array:3 [
          "ES" => true
          "ES2" => true
          "LATM" => true
        ]
        "gratuito" => true
        "lecturas" => array:1 [
          "total" => 0
        ]
        "idiomaDefecto" => "en"
        "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2013251418300178?idApp=UINPBA000064"
      ]
    ]
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S021169951730142X?idApp=UINPBA000064"
    "url" => "/02116995/0000003800000001/v1_201801090621/S021169951730142X/v1_201801090621/es/main.assets"
  ]
  "es" => array:14 [
    "idiomaDefecto" => true
    "cabecera" => "<span class="elsevierStyleTextfn">Editorial</span>"
    "titulo" => "El dializador en el a&#241;o 2017&#58; mucho m&#225;s que una membrana"
    "tieneTextoCompleto" => true
    "paginas" => array:1 [
      0 => array:2 [
        "paginaInicial" => "4"
        "paginaFinal" => "7"
      ]
    ]
    "autores" => array:1 [
      0 => array:4 [
        "autoresLista" => "Rafael P&#233;rez-Garc&#237;a, Roberto Alc&#225;zar"
        "autores" => array:2 [
          0 => array:4 [
            "nombre" => "Rafael"
            "apellidos" => "P&#233;rez-Garc&#237;a"
            "email" => array:2 [
              0 => "rperezgarcia&#64;senefro&#46;org"
              1 => "cerperezga&#64;salud&#46;madrid&#46;org"
            ]
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">&#42;</span>"
                "identificador" => "cor0005"
              ]
            ]
          ]
          1 => array:2 [
            "nombre" => "Roberto"
            "apellidos" => "Alc&#225;zar"
          ]
        ]
        "afiliaciones" => array:1 [
          0 => array:2 [
            "entidad" => "Servicio de Nefrolog&#237;a&#44; Hospital Infanta Leonor&#44; Madrid&#44; Espa&#241;a"
            "identificador" => "aff0005"
          ]
        ]
        "correspondencia" => array:1 [
          0 => array:3 [
            "identificador" => "cor0005"
            "etiqueta" => "&#8270;"
            "correspondencia" => "Autor para correspondencia&#46;"
          ]
        ]
      ]
    ]
    "titulosAlternativos" => array:1 [
      "en" => array:1 [
        "titulo" => "The dialyser in the year 2017&#58; much more than a membrane"
      ]
    ]
    "resumenGrafico" => array:2 [
      "original" => 0
      "multimedia" => array:7 [
        "identificador" => "fig0005"
        "etiqueta" => "Figura 1"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr1.jpeg"
            "Alto" => 1061
            "Ancho" => 1500
            "Tamanyo" => 153710
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">Tama&#241;o y distribuci&#243;n de los poros de las membranas&#46;</p> <p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">HCO&#58; membranas de alto punto de corte&#59; HF&#58; plasmafiltros y dializadores de alta eficacia&#59; MCO&#58; membranas de punto de corte medio&#47;poros intermedios&#59; n&#47;no&#58; n&#250;mero de poros de cada tama&#241;o normalizado en tanto por uno&#46;</p>"
        ]
      ]
    ]
    "textoCompleto" => "<span class="elsevierStyleSections"><p id="par0005" class="elsevierStylePara elsevierViewall">El dializador es el elemento central de la hemodi&#225;lisis&#44; donde se producen el intercambio de sustancias entre la sangre y el l&#237;quido de di&#225;lisis &#40;LD&#41;&#59; la ultrafiltraci&#243;n &#40;UF&#41; y la retrofiltraci&#243;n&#46; Desde las primeras di&#225;lisis con dializadores tubulares de colodi&#243;n&#44; trinitrato de celulosa&#44; conocido como dializador de Haas&#44; en 1924<a class="elsevierStyleCrossRef" href="#bib0145"><span class="elsevierStyleSup">1</span></a>&#44; la hemodi&#225;lisis y los dializadores han evolucionado enormemente&#46; En esta revisi&#243;n nos vamos a centrar en los cambios de los dializadores que han aparecido en las dos &#250;ltimas d&#233;cadas&#44; que puede que no sean tan evidentes&#46;</p><p id="par0010" class="elsevierStylePara elsevierViewall">Un dializador es m&#225;s que una membrana&#44; pero est&#225; claro que esta es uno de sus componentes fundamentales&#46; Los poros de la membrana de un dializador deben ser de un tama&#241;o determinado&#44; numerosos y uniformes&#46; Esto se consigue con la nanotecnolog&#237;a<a class="elsevierStyleCrossRef" href="#bib0150"><span class="elsevierStyleSup">2</span></a>&#46; La formaci&#243;n de una capa proteica en la membrana&#44; al ponerse en contacto con la sangre&#44; restringe la eliminaci&#243;n de mol&#233;culas&#44; modificando funcionalmente los poros<a class="elsevierStyleCrossRef" href="#bib0155"><span class="elsevierStyleSup">3</span></a>&#46; De la aplicaci&#243;n de la nanotecnolog&#237;a van a depender varias de las especificaciones que se mencionan a continuaci&#243;n&#46;</p><p id="par0015" class="elsevierStylePara elsevierViewall">El coeficiente de ultrafiltraci&#243;n &#40;CUF&#41; de un dializador es una de las caracter&#237;sticas que m&#225;s se valoran&#46; El CUF y el dise&#241;o del dializador van a condicionar la retrofiltraci&#243;n&#44; que no debe generar ninguna preocupaci&#243;n con un LD ultrapuro<a class="elsevierStyleCrossRef" href="#bib0160"><span class="elsevierStyleSup">4</span></a>&#44; requisito imprescindible hoy en d&#237;a&#46; De hecho&#44; es una forma de eliminar mol&#233;culas medias y grandes sin tener que recurrir a la hemodiafiltraci&#243;n &#40;HDF&#41;&#46; Un CUF alto&#44; mayor de 40<span class="elsevierStyleHsp" style=""></span>ml&#47;mmHg&#47;h&#44; es un requisito de un dializador moderno&#46;</p><p id="par0020" class="elsevierStylePara elsevierViewall">El coeficiente de cribado &#40;CC&#41; debe ser alto para mol&#233;culas medias&#44; sin p&#233;rdidas significativas de alb&#250;mina&#46; En la hemodi&#225;lisis moderna necesitamos marcadores de eliminaci&#243;n de mol&#233;culas medias y grandes&#46; El m&#225;s utilizado es el CC para la &#946;2 microglobulina&#44; que deber&#237;a ser mayor de 0&#44;6 para el grupo EUDIAL<a class="elsevierStyleCrossRef" href="#bib0165"><span class="elsevierStyleSup">5</span></a>&#46; En la mayor&#237;a de los dializadores modernos es superior a 0&#44;7&#46; El CUF depende del n&#250;mero de poros y del CC para la &#946;2 microglobulina&#44; de su tama&#241;o y uniformidad&#46; Lo anterior debe ser compatible con una m&#237;nima eliminaci&#243;n de alb&#250;mina&#44; con un CC menor de 0&#44;01&#46; La p&#233;rdida de alb&#250;mina hay que valorarla al inicio de la sesi&#243;n y cuando se somete el dializador a presiones transmembrana elevadas&#44; como ocurre en la hemodiafiltraci&#243;n en l&#237;nea &#40;HDF-OL&#41;&#46; En estas condiciones la p&#233;rdida de alb&#250;mina deber&#237;a ser menor de 4<span class="elsevierStyleHsp" style=""></span>g por sesi&#243;n<a class="elsevierStyleCrossRef" href="#bib0170"><span class="elsevierStyleSup">6</span></a>&#46;</p><p id="par0025" class="elsevierStylePara elsevierViewall">La distribuci&#243;n del LD debe ser uniforme en el dializador&#44; no debe haber circuitos preferenciales&#44; que eviten el contacto con los capilares&#46; Esto se mejor&#243; incluyendo filamentos intercalados&#44; ondulando las fibras y mediante otros artificios&#46; Actualmente se logra con una densidad de fibras muy alta&#44; superior a 11&#46;000&#46; Con estos dializadores el flujo del LD &#40;Qd&#41; &#243;ptimo en hemodi&#225;lisis y HDF-OL est&#225; entre 400 y 500<span class="elsevierStyleHsp" style=""></span>ml&#47;min<a class="elsevierStyleCrossRefs" href="#bib0175"><span class="elsevierStyleSup">7-9</span></a> y no tiene justificaci&#243;n utilizar un Qd de 700 a 1&#46;000<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#46;</p><p id="par0030" class="elsevierStylePara elsevierViewall">La eliminaci&#243;n de agua y solutos de peque&#241;o peso molecular ha obligado a mantener una cierta hidrofilia en la membrana&#46; Esto en las membranas sint&#233;ticas se logra mediante la polivinilpirrolidona &#40;PVP&#41;&#46; Este compuesto est&#225; en las membranas sint&#233;ticas hidr&#243;fobas en mayor o menor cantidad y m&#225;s o menos imbuido en la membrana&#46; Su aparici&#243;n en el eluido podr&#237;a estar en relaci&#243;n con las reacciones al&#233;rgicas que presentan actualmente algunos pacientes con las membranas sint&#233;ticas<a class="elsevierStyleCrossRefs" href="#bib0190"><span class="elsevierStyleSup">10&#44;11</span></a>&#46; El aspecto cl&#237;nico m&#225;s evidente de la bioincompatibilidad de los dializadores son las reacciones adversas&#46; Estas reacciones adversas se denominan habitualmente como reacciones de hipersensibilidad tipos A y B&#46; Actualmente creemos que es m&#225;s &#250;til definirlas por su cl&#237;nica y causa&#46; Ha habido reacciones por degranulaci&#243;n de los bas&#243;filos espec&#237;fica o inespec&#237;fica al &#243;xido de etileno &#40;ETO&#41;&#44; activaci&#243;n del complemento por el cuprof&#225;n y otras membranas celul&#243;sicas&#44; reacciones al AN-69 junto con los IECA&#44; entre otras&#46; En los &#250;ltimos a&#241;os asistimos a reacciones en algunos pacientes con el uso de membranas sint&#233;ticas con PVP&#44; que dejan de aparecer al cambiarlos a dializadores de triacetato de celulosa<a class="elsevierStyleCrossRefs" href="#bib0200"><span class="elsevierStyleSup">12&#44;13</span></a>&#46; En la actualidad contamos con dializadores de triacetato de celulosa asim&#233;trico de alto flujo&#44; con un CUF de 87<span class="elsevierStyleHsp" style=""></span>ml&#47;mmHg&#47;h y grandes prestaciones en HDF-OL<a class="elsevierStyleCrossRef" href="#bib0210"><span class="elsevierStyleSup">14</span></a>&#46; Los nuevos dializadores deben solucionar estas interacciones con la sangre&#44; ejemplo de ello ha sido la no esterilizaci&#243;n de los dializadores con ETO&#46; Tambi&#233;n&#44; los materiales de la carcasa del dializador y los necesarios para el ensamblaje pueden desencadenar reacciones adversas o toxicidad&#46; Por &#250;ltimo se deber&#237;an eliminar otras sustancias t&#243;xicas&#44; como el bisfenol &#40;BPA&#41;<a class="elsevierStyleCrossRefs" href="#bib0215"><span class="elsevierStyleSup">15&#44;16</span></a>&#46;</p><p id="par0035" class="elsevierStylePara elsevierViewall">En los &#250;ltimos a&#241;os los dializadores se han ido especializando en funci&#243;n de la t&#233;cnica de di&#225;lisis&#46; Los de alto punto de corte &#40;HCO&#41;&#44; poros grandes&#44; para eliminar la mayor cantidad de mol&#233;culas como las cadenas ligeras de las inmunoglobulinas en el tratamiento del ri&#241;&#243;n de mieloma<a class="elsevierStyleCrossRefs" href="#bib0225"><span class="elsevierStyleSup">17&#44;18</span></a>&#46; Recientemente se han desarrollado membranas&#44; de punto de corte medio &#40;MCO&#41; &#40;<a class="elsevierStyleCrossRef" href="#fig0005">fig&#46; 1</a>&#41;&#44; con capacidad de eliminaci&#243;n de mol&#233;culas como las HCO&#44; pero capaces de retener la alb&#250;mina &#40;<a class="elsevierStyleCrossRef" href="#fig0010">fig&#46; 2</a>&#41;<a class="elsevierStyleCrossRef" href="#bib0155"><span class="elsevierStyleSup">3</span></a>&#46; Con estos dializadores se puede obtener una depuraci&#243;n de mol&#233;culas medias superior que con los dializadores de alta eficacia &#40;<span class="elsevierStyleItalic">high-flux</span> &#91;HF&#93;&#41;<a class="elsevierStyleCrossRef" href="#bib0235"><span class="elsevierStyleSup">19</span></a>&#46;</p><elsevierMultimedia ident="fig0005"></elsevierMultimedia><elsevierMultimedia ident="fig0010"></elsevierMultimedia><p id="par0040" class="elsevierStylePara elsevierViewall">Por otro lado&#44; se han dise&#241;ado dializadores para aprovechar la retrofiltraci&#243;n&#44; como forma de depuraci&#243;n por trasporte convectivo interno<a class="elsevierStyleCrossRef" href="#bib0240"><span class="elsevierStyleSup">20</span></a>&#44; lo que se ha denominado hemodiafiltraci&#243;n interna &#40;HDFi&#41;<a class="elsevierStyleCrossRef" href="#bib0245"><span class="elsevierStyleSup">21</span></a>&#46; Una de las formas de aumentar la HDFi es aumentar la densidad de los capilares&#44; &#8805;<span class="elsevierStyleHsp" style=""></span>74&#37;&#44; logrando una HDFi de 3&#44;5<span class="elsevierStyleHsp" style=""></span>l&#47;h<a class="elsevierStyleCrossRef" href="#bib0250"><span class="elsevierStyleSup">22</span></a>&#46; Otra forma es disminuir el di&#225;metro interno de los capilares para aumentar las resistencias internas y lograr mayor retrofiltraci&#243;n&#46; En esa disminuci&#243;n por debajo de 200<span class="elsevierStyleHsp" style=""></span>&#956;m se ha llegado hasta las 180<span class="elsevierStyleHsp" style=""></span>&#956; de di&#225;metro&#44; como en el dializador Theranova&#8482;&#46; Hay que recordar que el radio interno del capilar figura a la cuarta potencia en la ecuaci&#243;n de Hagen-Poiseuille para calcular la resistencia de la sangre al paso por los capilares&#46; Un dializador largo&#44; estrecho y con un di&#225;metro de los capilares de 185-180<span class="elsevierStyleHsp" style=""></span>&#956;m va a provocar una ca&#237;da de presi&#243;n dentro del capilar muy grande&#44; de alrededor de 200<span class="elsevierStyleHsp" style=""></span>mmHg para 500 de Qb&#46; Este dise&#241;o ser&#237;a el ideal para un dializador para una hemodi&#225;lisis de muy alta eficacia&#44; en ingl&#233;s de HD-VHF&#46; Estos dializadores no se recomiendan para HDF-OL&#46; En HDF-OL se recomiendan dializadores con un di&#225;metro interno de los capilares igual o mayor de 200<span class="elsevierStyleHsp" style=""></span>&#956;m&#46; As&#237; la empresa Fresenius &#40;FMC&#8482;&#41; cre&#243; una l&#237;nea de dializadores FXclass<span class="elsevierStyleSup">&#174;</span> espec&#237;fica&#44; como el Fx800<span class="elsevierStyleSup">&#174;</span>&#44; distinto del Fx80<span class="elsevierStyleSup">&#174;</span>&#46; En este n&#250;mero de <span class="elsevierStyleSmallCaps">Nefrolog&#237;a</span> se publica un estudio en el que el Dr&#46; Maduell et al&#46;<a class="elsevierStyleCrossRef" href="#bib0255"><span class="elsevierStyleSup">23</span></a> demuestran unas tasas de reducci&#243;n de mol&#233;culas peque&#241;as y medianas semejantes en HDF-OL posdilucional con autosustituci&#243;n<span class="elsevierStyleSup">&#174;</span> comparando dializadores FX60 vs&#46; FX600 y FX80 vs&#46; FX800&#46; En HDF-OL la eliminaci&#243;n de mol&#233;culas medias depende fundamentalmente del volumen ultrafiltrado y del CC de cada mol&#233;cula&#46; Con los dos tipos de dializadores consiguen una depuraci&#243;n semejante&#46; El trabajo est&#225; realizado en condiciones &#243;ptimas&#44; Qb 450<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#44; 283<span class="elsevierStyleHsp" style=""></span>min de sesi&#243;n con una media de 32&#44;5<span class="elsevierStyleHsp" style=""></span>l de UF por sesi&#243;n&#46; Lo anterior significa una fracci&#243;n de filtraci&#243;n media del 25&#44;5&#37;&#44; no muy alta&#44; y con un hematocrito medio del 29&#37;&#46; Los dializadores que se recomiendan para HDF-OL posdilucional est&#225;n dise&#241;ados no para lograr m&#225;s volumen de UF y mayor eliminaci&#243;n de mol&#233;culas&#44; sino para evitar las complicaciones propias de la hemoconcentraci&#243;n en situaciones menos favorables y con fracciones de filtraci&#243;n mayores&#44; de alrededor del 30&#37;&#46; Nosotros publicamos un trabajo<a class="elsevierStyleCrossRef" href="#bib0260"><span class="elsevierStyleSup">24</span></a> comparando en HDF-OL posdilucional 4 dializadores&#58; FX1000<span class="elsevierStyleSup">&#174;</span>&#44; FX800<span class="elsevierStyleSup">&#174;</span>&#44; Polyflux 210H<span class="elsevierStyleSup">&#174;</span> y Elisio 210H<span class="elsevierStyleSup">&#174;</span>&#46; Los 3 primeros con un dise&#241;o para HDF-OL y el &#250;ltimo para HD-HF&#46; La tasa de reducci&#243;n de la concentraci&#243;n de las mol&#233;culas evaluadas fue semejante con los 4 dializadores&#44; as&#237; como el volumen ultrafiltrado&#46; La diferencia estuvo en el n&#250;mero de alarmas&#47;problemas que aparecieron en la m&#225;quina de di&#225;lisis con el Elisio<span class="elsevierStyleSup">&#174;</span>&#44; lo que se debi&#243; a un aumento de la presi&#243;n predializador superior en m&#225;s de 100<span class="elsevierStyleHsp" style=""></span>mmHg respecto a los otros 3 dializadores&#46; En este trabajo los Qb eran menores y 3 pacientes ten&#237;an un cat&#233;ter como acceso vascular&#46; La selecci&#243;n de los dializadores id&#243;neos para HDF-OL ya ha sido abordada<a class="elsevierStyleCrossRefs" href="#bib0265"><span class="elsevierStyleSup">25&#44;26</span></a>&#46; Por tanto&#44; no se pueden extrapolar las conclusiones del trabajo de Maduell et al&#46; en condiciones de di&#225;lisis menos &#243;ptimas&#46;</p><p id="par0045" class="elsevierStylePara elsevierViewall">Tambi&#233;n se ha avanzado en la capacidad de adsorci&#243;n de algunas membranas&#44; como el PMMA&#44; disminuyendo su capacidad de activar las plaquetas y su trombogenicidad<a class="elsevierStyleCrossRef" href="#bib0275"><span class="elsevierStyleSup">27</span></a>&#46; En otros se ha aprovechado esa capacidad adsortiva para injertar heparina y disminuir la trombogenicidad<a class="elsevierStyleCrossRef" href="#bib0280"><span class="elsevierStyleSup">28</span></a>&#46; Su asociaci&#243;n a un LD con citrato logra resultados prometedores evitando tener que utilizar anticoagulaci&#243;n en la HD<a class="elsevierStyleCrossRef" href="#bib0280"><span class="elsevierStyleSup">28</span></a>&#46;</p><p id="par0050" class="elsevierStylePara elsevierViewall">Otros aspectos a tener en cuenta en el dializador son&#58; el volumen en el compartimento sangu&#237;neo&#44; siendo &#243;ptimo por debajo &#60;<span class="elsevierStyleHsp" style=""></span>120<span class="elsevierStyleHsp" style=""></span>ml&#44; para 2<span class="elsevierStyleHsp" style=""></span>m<span class="elsevierStyleSup">2</span> y volumen de sangre residual &#60;<span class="elsevierStyleHsp" style=""></span>1<span class="elsevierStyleHsp" style=""></span>ml&#46; La superficie del dializador deber&#237;a estar en funci&#243;n del Qb que se alcanza&#46; La esterilizaci&#243;n&#58; el ETO se ha ido desterrando como m&#233;todo de esterilizaci&#243;n de los dializadores&#46; El vapor de agua y la radiaci&#243;n gamma son los m&#233;todos m&#225;s frecuentes actualmente&#46; Cuando valoremos los datos de un dializador&#44; debemos comprobar que las pruebas in vitro deben atenerse a especificaciones est&#225;ndar&#44; como la ISO 8637&#58; 2014&#46;</p><p id="par0055" class="elsevierStylePara elsevierViewall">En la <a class="elsevierStyleCrossRef" href="#tbl0005">tabla 1</a> se enumeran las caracter&#237;sticas que nos deben orientar en la elecci&#243;n de un dializador para una t&#233;cnica de di&#225;lisis y un paciente en concreto&#46; Algunas de esas caracter&#237;sticas se pueden considerar como criterios de calidad de un dializador&#46;</p><elsevierMultimedia ident="tbl0005"></elsevierMultimedia><p id="par0060" class="elsevierStylePara elsevierViewall">Los avances tecnol&#243;gicos han permitido que los dializadores hayan evolucionado enormemente en los &#250;ltimos a&#241;os&#44; consiguiendo que la hemodi&#225;lisis sea m&#225;s eficaz&#44; m&#225;s eficiente y m&#225;s segura&#46; Al igual que estamos individualizando la prescripci&#243;n del LD&#44; la tendencia actual es la de adecuar la elecci&#243;n del dializador a la t&#233;cnica y a las caracter&#237;sticas del acceso vascular de cada paciente&#46; Se est&#225; mejorando y se tiene que mejorar todav&#237;a m&#225;s en la biocompatibilidad de las membranas y dializadores para disminuir el riesgo de efectos adversos&#46;</p><p id="par0065" class="elsevierStylePara elsevierViewall">Los poros funcionalmente se modifican por varios factores&#44; fundamentalmente por el contacto con la sangre y por la presi&#243;n a la que se somete la membrana&#46;</p><span id="sec0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0005">Puntos clave</span><p id="par0070" class="elsevierStylePara elsevierViewall"><ul class="elsevierStyleList" id="lis0005"><li class="elsevierStyleListItem" id="lsti0005"><span class="elsevierStyleLabel">1&#46;</span><p id="par0075" class="elsevierStylePara elsevierViewall">Los avances tecnol&#243;gicos en los dializadores permiten&#44; hoy d&#237;a&#44; individualizar la elecci&#243;n del dializador a la t&#233;cnica y a las caracter&#237;sticas del acceso vascular en cada paciente&#46;</p></li><li class="elsevierStyleListItem" id="lsti0010"><span class="elsevierStyleLabel">2&#46;</span><p id="par0080" class="elsevierStylePara elsevierViewall">De la hemodi&#225;lisis de alto flujo &#40;HF&#41; debemos pasar a la hemodiafiltraci&#243;n interna &#40;HDFi&#41;&#46; La HDFi no se debe considerar un competidor de la hemodiafiltraci&#243;n en l&#237;nea &#40;HDF-OL&#41;&#44; ser&#237;a una alternativa para aplicar las ventajas del trasporte convectivo a pacientes no susceptibles de HDF-OL&#44; implicar&#237;a menos requerimientos t&#233;cnicos y un menor coste&#46; Est&#225;n por demostrar sus beneficios a nivel cl&#237;nico&#46;</p></li><li class="elsevierStyleListItem" id="lsti0015"><span class="elsevierStyleLabel">3&#46;</span><p id="par0085" class="elsevierStylePara elsevierViewall">La HDF-OL en situaciones no &#243;ptimas y con fracciones de filtraci&#243;n del 30&#37; precisan de dializadores espec&#237;ficos&#46;</p></li><li class="elsevierStyleListItem" id="lsti0020"><span class="elsevierStyleLabel">4&#46;</span><p id="par0090" class="elsevierStylePara elsevierViewall">Los dializadores actuales deben evitar las reacciones adversas&#44; incluyendo las reacciones de hipersensibilidad y t&#243;xicas&#46; Deben seguir mejorando su biocompatibilidad&#46;</p></li><li class="elsevierStyleListItem" id="lsti0025"><span class="elsevierStyleLabel">5&#46;</span><p id="par0095" class="elsevierStylePara elsevierViewall">En la HDFi y en la HDF-OL las p&#233;rdidas de alb&#250;mina deben ser peque&#241;as&#44; en todo caso con coeficientes de cribado &#40;CC&#41; menores de 0&#44;01 y menores de 4<span class="elsevierStyleHsp" style=""></span>g por sesi&#243;n&#46;</p></li></ul></p></span></span>"
    "textoCompletoSecciones" => array:1 [
      "secciones" => array:2 [
        0 => array:2 [
          "identificador" => "sec0005"
          "titulo" => "Puntos clave"
        ]
        1 => array:1 [
          "titulo" => "Bibliograf&#237;a"
        ]
      ]
    ]
    "pdfFichero" => "main.pdf"
    "tienePdf" => true
    "multimedia" => array:3 [
      0 => array:7 [
        "identificador" => "fig0005"
        "etiqueta" => "Figura 1"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr1.jpeg"
            "Alto" => 1061
            "Ancho" => 1500
            "Tamanyo" => 153710
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">Tama&#241;o y distribuci&#243;n de los poros de las membranas&#46;</p> <p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">HCO&#58; membranas de alto punto de corte&#59; HF&#58; plasmafiltros y dializadores de alta eficacia&#59; MCO&#58; membranas de punto de corte medio&#47;poros intermedios&#59; n&#47;no&#58; n&#250;mero de poros de cada tama&#241;o normalizado en tanto por uno&#46;</p>"
        ]
      ]
      1 => array:7 [
        "identificador" => "fig0010"
        "etiqueta" => "Figura 2"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr2.jpeg"
            "Alto" => 1544
            "Ancho" => 2500
            "Tamanyo" => 410989
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">Microfotograf&#237;a de la cara interna de los 4 tipos de membranas en funci&#243;n del tama&#241;o de los poros&#58; A&#41; alta eficacia &#40;HF&#41;&#59; B&#41; punto de corte medio &#40;MCO&#41; &#40;Theranova<span class="elsevierStyleSup">&#174;</span>&#41;&#59; C&#41; alto punto de corte &#40;HCO&#41;&#59; D&#41; plasmafiltro&#46; Magnificaci&#243;n 60&#46;000&#215;&#46;</p>"
        ]
      ]
      2 => array:8 [
        "identificador" => "tbl0005"
        "etiqueta" => "Tabla 1"
        "tipo" => "MULTIMEDIATABLA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "detalles" => array:1 [
          0 => array:3 [
            "identificador" => "at1"
            "detalle" => "Tabla "
            "rol" => "short"
          ]
        ]
        "tabla" => array:1 [
          "tablatextoimagen" => array:1 [
            0 => array:2 [
              "tabla" => array:1 [
                0 => """
                  <table border="0" frame="\n
                  \t\t\t\t\tvoid\n
                  \t\t\t\t" class=""><tbody title="tbody"><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">1&#46; CUF alto&#44; &#62;<span class="elsevierStyleHsp" style=""></span>40<span class="elsevierStyleHsp" style=""></span>ml&#47;mmHg&#47;h&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">2&#46; Coeficiente de cribado para la &#946;2 microglobulina &#62;<span class="elsevierStyleHsp" style=""></span>0&#44;7&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">3&#46; Coeficiente de cribado &#60;<span class="elsevierStyleHsp" style=""></span>0&#44;01 para la alb&#250;mina&#46; En HDF-OL la p&#233;rdida de alb&#250;mina por sesi&#243;n deber&#237;a ser &#60;<span class="elsevierStyleHsp" style=""></span>4<span class="elsevierStyleHsp" style=""></span>g&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">4&#46; Alta densidad de empaquetado de los capilares&#44; &#62;<span class="elsevierStyleHsp" style=""></span>11&#46;000&#44; que permita dializar con Qd entre 400 y 500<span class="elsevierStyleHsp" style=""></span>ml&#47;min con buen rendimiento&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">5&#46; Altas resistencias internas en hemodi&#225;lisis&#44; dializadores largos y con di&#225;metro interno de los capilares &#60;<span class="elsevierStyleHsp" style=""></span>200<span class="elsevierStyleHsp" style=""></span>&#956;m&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">6&#46; En HDF-OL posdilucional&#44; si se funciona con Qb limitados&#44; Hto&#46; alto&#44; FF &#8764;<span class="elsevierStyleHsp" style=""></span>30&#37;&#44; dializadores con &#62;<span class="elsevierStyleHsp" style=""></span>200<span class="elsevierStyleHsp" style=""></span>&#956;m de di&#225;metro interno de los capilares&#46; Presi&#243;n prefiltro &#60;<span class="elsevierStyleHsp" style=""></span>700<span class="elsevierStyleHsp" style=""></span>mmHg&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">7&#46; Esterilizaci&#243;n libre de ETO&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">8&#46; Buena biocompatibilidad&#46; Recomendable&#44; libre de BPA y otros t&#243;xicos y no reacciones adversas&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr></tbody></table>
                  """
              ]
              "imagenFichero" => array:1 [
                0 => "xTab1639257.png"
              ]
            ]
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p id="spar0020" class="elsevierStyleSimplePara elsevierViewall">Caracter&#237;sticas de un dializador recomendables para realizar una hemodi&#225;lisis o hemodiafiltraci&#243;n actual &#243;ptima</p>"
        ]
      ]
    ]
    "bibliografia" => array:2 [
      "titulo" => "Bibliograf&#237;a"
      "seccion" => array:1 [
        0 => array:2 [
          "identificador" => "bibs0015"
          "bibliografiaReferencia" => array:28 [
            0 => array:3 [
              "identificador" => "bib0145"
              "etiqueta" => "1"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Versuche der Blutauswaschung am Lebenden mit Hilfe der Dialyse"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:1 [
                            0 => "G&#46; Haas"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:4 [
                        "tituloSerie" => "Klin Woechenschrift&#44;"
                        "fecha" => "1925"
                        "volumen" => "4"
                        "paginaInicial" => "13"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            1 => array:3 [
              "identificador" => "bib0150"
              "etiqueta" => "2"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Hemodialysis membranes for high-volume hemodialytic therapies&#58; The application of nanotechnology"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "C&#46; Ronco"
                            1 => "B&#46; Breuer"
                            2 => "S&#46;K&#46; Bowry"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Hemodial Int&#46;"
                        "fecha" => "2006"
                        "volumen" => "10"
                        "paginaInicial" => "48"
                        "paginaFinal" => "50"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            2 => array:3 [
              "identificador" => "bib0155"
              "etiqueta" => "3"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "MCO membranes&#58; Enhances selectivity in high-flux class"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:4 [
                            0 => "A&#46; Boschetti-de-Fierro"
                            1 => "M&#46; Voigt"
                            2 => "M&#46; Storr"
                            3 => "B&#46; Krause"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1038/srep18448"
                      "Revista" => array:5 [
                        "tituloSerie" => "Sci Rep&#46;"
                        "fecha" => "2015"
                        "volumen" => "5"
                        "paginaInicial" => "18448"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26669756"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            3 => array:3 [
              "identificador" => "bib0160"
              "etiqueta" => "4"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Gu&#237;a de gesti&#243;n de calidad del l&#237;quido de di&#225;lisis &#40;LD&#41; &#40;segunda edici&#243;n&#44; 2015&#41;"
                      "autores" => array:1 [
                        0 => array:3 [
                          "colaboracion" => "Comisi&#243;n de Expertos de la Sociedad Espa&#241;ola de Nefrolog&#237;a para la creaci&#243;n de la segunda edici&#243;n de la Gu&#237;a de gesti&#243;n de calidad del l&#237;quido de di&#225;lisis"
                          "etal" => true
                          "autores" => array:6 [
                            0 => "R&#46; P&#233;rez-Garc&#237;a"
                            1 => "R&#46; Garc&#237;a Maset"
                            2 => "E&#46; Gonzalez Parra"
                            3 => "C&#46; Soloz&#225;bal Campos"
                            4 => "R&#46; Ram&#237;rez Chamond"
                            5 => "P&#46; Mart&#237;n-Rabad&#225;n"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.nefro.2016.01.003"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nefrolog&#237;a&#46;"
                        "fecha" => "2016"
                        "volumen" => "36"
                        "paginaInicial" => "e1"
                        "paginaFinal" => "e52"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26988922"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            4 => array:3 [
              "identificador" => "bib0165"
              "etiqueta" => "5"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Online haemodiafiltration&#58; Definition&#44; dose quantification and safety revisited"
                      "autores" => array:1 [
                        0 => array:3 [
                          "colaboracion" => "EUDIAL group"
                          "etal" => false
                          "autores" => array:2 [
                            0 => "J&#46;E&#46; Tattersall"
                            1 => "R&#46;A&#46; Ward"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1093/ndt/gfs530"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nephrol Dial Transplant&#46;"
                        "fecha" => "2013"
                        "volumen" => "28"
                        "paginaInicial" => "542"
                        "paginaFinal" => "550"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23345621"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            5 => array:3 [
              "identificador" => "bib0170"
              "etiqueta" => "6"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Influence of high convection volumes in removal performances of on-line haemodiafiltration &#40;HDF&#41;"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "N&#46; Gayrard"
                            1 => "A&#46; Ficheux"
                            2 => "F&#46; Duranton"
                            3 => "C&#46; Guzman"
                            4 => "I&#46; Szwarc"
                            5 => "J&#46; Bismuth-Mondolfo"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Nephrol Dial Transplant"
                        "fecha" => "2013"
                        "volumen" => "28"
                        "numero" => "Suppl&#46; 1"
                        "paginaInicial" => "i30"
                        "paginaFinal" => "i32"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            6 => array:3 [
              "identificador" => "bib0175"
              "etiqueta" => "7"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Is it useful to increase dialysate flow rate to improve the delivered Kt&#63;"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "M&#46; Albalate"
                            1 => "R&#46; P&#233;rez-Garc&#237;a"
                            2 => "P&#46; de Sequera"
                            3 => "E&#46; Corchete"
                            4 => "R&#46; Alcazar"
                            5 => "M&#46; Ortega"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1186/s12882-015-0013-9"
                      "Revista" => array:5 [
                        "tituloSerie" => "BMC Nephrol&#46;"
                        "fecha" => "2015"
                        "volumen" => "16"
                        "paginaInicial" => "20"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25884763"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            7 => array:3 [
              "identificador" => "bib0180"
              "etiqueta" => "8"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "&#191;Cu&#225;l es el flujo de ba&#241;o &#243;ptimo en la hemodiafiltraci&#243;n on-line posdilucional&#63;"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "M&#46; Albalate"
                            1 => "P&#46; de Sequera"
                            2 => "R&#46; P&#233;rez-Garc&#237;a"
                            3 => "E&#46; Corchete"
                            4 => "R&#46; Alc&#225;zar"
                            5 => "M&#46; Ortega"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.nefro.2015.04.007"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nefrolog&#237;a&#46;"
                        "fecha" => "2015"
                        "volumen" => "35"
                        "paginaInicial" => "533"
                        "paginaFinal" => "538"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26565938"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            8 => array:3 [
              "identificador" => "bib0185"
              "etiqueta" => "9"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Optimization of dialysate flow in on-line hemodiafiltration"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "F&#46; Maduell"
                            1 => "R&#46; Ojeda"
                            2 => "M&#46; Arias-Guill&#233;n"
                            3 => "N&#46; Fontser&#233;"
                            4 => "M&#46; Vera"
                            5 => "E&#46; Mass&#243;"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.nefro.2015.06.019"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nefrolog&#237;a&#46;"
                        "fecha" => "2015"
                        "volumen" => "35"
                        "paginaInicial" => "473"
                        "paginaFinal" => "478"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26306957"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            9 => array:3 [
              "identificador" => "bib0190"
              "etiqueta" => "10"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Poly&#40;N-vinyl-2-pyrrolidone&#41; elution from polysulfone dialysis membranes by varying solvent and wall shear stress"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:5 [
                            0 => "K&#46; Namekawa"
                            1 => "M&#46; Matsuda"
                            2 => "M&#46; Fukuda"
                            3 => "A&#46; Kaneko"
                            4 => "K&#46; Sakai"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1007/s10047-012-0629-5"
                      "Revista" => array:6 [
                        "tituloSerie" => "J Artif Organs&#46;"
                        "fecha" => "2012"
                        "volumen" => "15"
                        "paginaInicial" => "185"
                        "paginaFinal" => "192"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22311608"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            10 => array:3 [
              "identificador" => "bib0195"
              "etiqueta" => "11"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Eluted substances from hemodialysis membranes elicit positive skin prick tests in bioincompatible patients"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:5 [
                            0 => "S&#46; Konishi"
                            1 => "A&#46; Fukunaga"
                            2 => "H&#46; Yamashita"
                            3 => "M&#46; Miyata"
                            4 => "M&#46; Usami"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1111/aor.12392"
                      "Revista" => array:6 [
                        "tituloSerie" => "Artif Organs&#46;"
                        "fecha" => "2015"
                        "volumen" => "39"
                        "paginaInicial" => "343"
                        "paginaFinal" => "351"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25327279"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            11 => array:3 [
              "identificador" => "bib0200"
              "etiqueta" => "12"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Hypersensitivity reactions to synthetic haemodialysis membranes &#8212; an emerging issue&#63;"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:2 [
                            0 => "M&#46;A&#46; Alvarez-de Lara"
                            1 => "A&#46; Mart&#237;n-Malo"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.3265/Nefrologia.pre2014.Jul.12682"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nefrolog&#237;a&#46;"
                        "fecha" => "2014"
                        "volumen" => "34"
                        "paginaInicial" => "698"
                        "paginaFinal" => "702"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25415569"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            12 => array:3 [
              "identificador" => "bib0205"
              "etiqueta" => "13"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Hypersensitivity reactions to synthetic haemodialysis membranes"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "R&#46;J&#46; S&#225;nchez-Villanueva"
                            1 => "E&#46; Gonz&#225;lez"
                            2 => "S&#46; Quirce"
                            3 => "R&#46; D&#237;az"
                            4 => "L&#46; Alvarez"
                            5 => "D&#46; Men&#233;ndez"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.3265/Nefrologia.pre2014.May.12552"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nefrolog&#237;a&#46;"
                        "fecha" => "2014"
                        "volumen" => "34"
                        "paginaInicial" => "520"
                        "paginaFinal" => "525"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25036066"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            13 => array:3 [
              "identificador" => "bib0210"
              "etiqueta" => "14"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Efecto del triacetato de celulosa asim&#233;trico &#40;Solacea<span class="elsevierStyleSup">&#174;</span>&#41; en hemodiafiltraci&#243;n on line &#40;HDF Ol&#41;&#44; sobre monocitos inflamatorios"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "M&#46; Albalate"
                            1 => "P&#46; Martinez Miguel"
                            2 => "I&#46; Bohorquez"
                            3 => "P&#46; de Sequera"
                            4 => "H&#46; Bouarich"
                            5 => "R&#46; Ramirez"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Nefrolog&#237;a&#46;"
                        "fecha" => "2016"
                        "volumen" => "36"
                        "numero" => "Supl&#46; 1"
                        "paginaInicial" => "70"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            14 => array:3 [
              "identificador" => "bib0215"
              "etiqueta" => "15"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "The choice of hemodialysis membrane affects bisphenol A levels in blood"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "E&#46; Bosch-Panadero"
                            1 => "S&#46; Mas"
                            2 => "D&#46; Sanchez-Ospina"
                            3 => "V&#46; Camarero"
                            4 => "M&#46;V&#46; P&#233;rez-G&#243;mez"
                            5 => "I&#46; Saez-Calero"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1681/ASN.2015030312"
                      "Revista" => array:6 [
                        "tituloSerie" => "J Am Soc Nephrol&#46;"
                        "fecha" => "2016"
                        "volumen" => "27"
                        "paginaInicial" => "1566"
                        "paginaFinal" => "1574"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26432902"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            15 => array:3 [
              "identificador" => "bib0220"
              "etiqueta" => "16"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Bisphenol A in hemodialysis patient&#58; An open question"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:1 [
                            0 => "M&#46; Neri"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1159/000446227"
                      "Revista" => array:6 [
                        "tituloSerie" => "Blood Purif&#46;"
                        "fecha" => "2016"
                        "volumen" => "42"
                        "paginaInicial" => "75"
                        "paginaFinal" => "76"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/27189594"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            16 => array:3 [
              "identificador" => "bib0225"
              "etiqueta" => "17"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Therapeutic efficacy and cost effectiveness of high cut-off dialyzers compared to conventional dialysis in patients with cast nephropathy"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:5 [
                            0 => "A&#46; Curti"
                            1 => "A&#46; Schwarz"
                            2 => "J&#46; Trachsler"
                            3 => "Y&#46; Tomonaga"
                            4 => "P&#46;M&#46; Amb&#252;hl"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1371/journal.pone.0159942"
                      "Revista" => array:6 [
                        "tituloSerie" => "PLoS One&#46;"
                        "fecha" => "2016"
                        "volumen" => "11"
                        "paginaInicial" => "e0159942"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/27467401"
                            "web" => "Medline"
                          ]
                        ]
                        "itemHostRev" => array:3 [
                          "pii" => "S0140673612608150"
                          "estado" => "S300"
                          "issn" => "01406736"
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            17 => array:3 [
              "identificador" => "bib0230"
              "etiqueta" => "18"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Tratamiento con hemodi&#225;lisis del fracaso renal agudo en el mieloma m&#250;ltiple con filtros de alto poro &#40;high cut-off&#41;"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "G&#46; Mart&#237;n-Reyes"
                            1 => "R&#46; Toledo-Rojas"
                            2 => "A&#46; Torres-de Rueda"
                            3 => "E&#46; Sola-Moyano"
                            4 => "L&#46; Blanca-Martos"
                            5 => "L&#46; Fuentes-S&#225;nchez"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.3265/Nefrologia.pre2011.Nov.11094"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nefrolog&#237;a&#46;"
                        "fecha" => "2012"
                        "volumen" => "32"
                        "paginaInicial" => "35"
                        "paginaFinal" => "43"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22294003"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            18 => array:3 [
              "identificador" => "bib0235"
              "etiqueta" => "19"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Performance of hemodialysis with novel medium cut-off dialyzers"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "A&#46;H&#46; Kirsch"
                            1 => "R&#46; Lyko"
                            2 => "L&#46;G&#46; Nilsson"
                            3 => "W&#46; Beck"
                            4 => "M&#46; Amdahl"
                            5 => "P&#46; Lechner"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1093/ndt/gfw310"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nephrol Dial Transplant&#46;"
                        "fecha" => "2017"
                        "volumen" => "32"
                        "paginaInicial" => "165"
                        "paginaFinal" => "172"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/27587605"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            19 => array:3 [
              "identificador" => "bib0240"
              "etiqueta" => "20"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Convection-enhanced high-flux hemodialysis"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "L&#46; Kyungsoo"
                            1 => "K&#46; Lee"
                            2 => "J&#46;H&#46; Jeong"
                            3 => "C&#46;H&#46; Mun"
                            4 => "S&#46;R&#46; Lee"
                            5 => "K&#46;J&#46; Yoo"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1111/j.1525-1594.2007.00436.x"
                      "Revista" => array:6 [
                        "tituloSerie" => "Artif Organs&#46;"
                        "fecha" => "2007"
                        "volumen" => "31"
                        "paginaInicial" => "653"
                        "paginaFinal" => "658"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/17651122"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            20 => array:3 [
              "identificador" => "bib0245"
              "etiqueta" => "21"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Principles and practice of internal hemodiafiltration"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:2 [
                            0 => "G&#46;B&#46; Fiore"
                            1 => "C&#46; Ronco"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1159/000107248"
                      "Revista" => array:6 [
                        "tituloSerie" => "Contrib Nephrol&#46;"
                        "fecha" => "2007"
                        "volumen" => "158"
                        "paginaInicial" => "177"
                        "paginaFinal" => "184"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/17684356"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            21 => array:3 [
              "identificador" => "bib0250"
              "etiqueta" => "22"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Effect of high fiber density ratio polysulfone dialyzer on protein removal"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "T&#46; Tomo"
                            1 => "M&#46; Matsuyama"
                            2 => "T&#46; Nakata"
                            3 => "J&#46; Kadota"
                            4 => "S&#46; Toma"
                            5 => "N&#46; Koga"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1159/000133430"
                      "Revista" => array:6 [
                        "tituloSerie" => "Blood Purif&#46;"
                        "fecha" => "2008"
                        "volumen" => "26"
                        "paginaInicial" => "347"
                        "paginaFinal" => "353"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/18487878"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            22 => array:3 [
              "identificador" => "bib0255"
              "etiqueta" => "23"
              "referencia" => array:1 [
                0 => array:1 [
                  "referenciaCompleta" => "Maduell F&#44; Ojeda R&#44; Belmar L&#44; Mungu&#237;a P&#44; Sango C&#44; Mart&#237;nez-D&#237;az AI&#44; et al&#46; Valoraci&#243;n del di&#225;metro interno del dializador en hemodiafiltraci&#243;n on-line&#46; Nefrolog&#237;a&#46;"
                ]
              ]
            ]
            23 => array:3 [
              "identificador" => "bib0260"
              "etiqueta" => "24"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Sistema Ultracontrol<span class="elsevierStyleSup">&#174;</span> en la cl&#237;nica diaria de la hemodiafiltraci&#243;n en l&#237;nea posdilucional&#58; volumen de infusi&#243;n alcanzado y aplicabilidad con distintos dializadores"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "M&#46; Albalate Ram&#243;n"
                            1 => "R&#46; P&#233;rez Garc&#237;a"
                            2 => "P&#46; de Sequera Ortiz"
                            3 => "R&#46; Alc&#225;zar Arroyo"
                            4 => "E&#46; Corchete Prats"
                            5 => "M&#46; Puerta Carretero"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.3265/Nefrologia.pre2011.Sep.11122"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nefrolog&#237;a&#46;"
                        "fecha" => "2011"
                        "volumen" => "31"
                        "paginaInicial" => "683"
                        "paginaFinal" => "689"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22130284"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            24 => array:3 [
              "identificador" => "bib0265"
              "etiqueta" => "25"
              "referencia" => array:1 [
                0 => array:3 [
                  "comentario" => "Sa400"
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "D&#233;puration de la Beta2-microglobuline et pertes d&#225;lbumine en HDF post-dilution&#58; effect membrane"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:6 [
                            0 => "F&#46; Le Roy"
                            1 => "M&#46; Hanoy"
                            2 => "D&#46; Bertrand"
                            3 => "C&#46; Freguin"
                            4 => "S&#46; Grange"
                            5 => "M&#46; Godin"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:2 [
                        "tituloSerie" => "EDTA"
                        "fecha" => "2009"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            25 => array:3 [
              "identificador" => "bib0270"
              "etiqueta" => "26"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Are all dialyzers compatible with the convective volumes suggested for postdilution online hemodiafiltration&#63;"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "J&#46; Potier"
                            1 => "G&#46; Queffeulou"
                            2 => "J&#46; Bouet"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.5301/ijao.5000525"
                      "Revista" => array:6 [
                        "tituloSerie" => "Int J Artif Organs&#46;"
                        "fecha" => "2016"
                        "volumen" => "39"
                        "paginaInicial" => "460"
                        "paginaFinal" => "470"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/27791259"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            26 => array:3 [
              "identificador" => "bib0275"
              "etiqueta" => "27"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "A new Poly&#40;methyl methacrylate&#41; membrane Sialyzer NF&#44; with adsorptive and antithrombotic properties"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "W&#46; Oshihara"
                            1 => "H&#46; Fujieda"
                            2 => "Y&#46; Ueno"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1159/000450806"
                      "Revista" => array:6 [
                        "tituloSerie" => "Contrib Nephrol&#46;"
                        "fecha" => "2017"
                        "volumen" => "189"
                        "paginaInicial" => "230"
                        "paginaFinal" => "236"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/27951573"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            27 => array:3 [
              "identificador" => "bib0280"
              "etiqueta" => "28"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "A noninferiority trial comparing a heparin-grafted membrane plus citrate-containing dialysate versus regional citrate anticoagulation&#58; Results of the CiTED study"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:6 [
                            0 => "B&#46; Meijers"
                            1 => "C&#46; Metalidis"
                            2 => "T&#46; Vanhove"
                            3 => "R&#46; Poesen"
                            4 => "D&#46; Kuypers"
                            5 => "P&#46; Evenepoel"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1093/ndt/gfw461"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nephrol Dial Transplant&#46;"
                        "fecha" => "2017"
                        "volumen" => "32"
                        "paginaInicial" => "707"
                        "paginaFinal" => "714"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/28407129"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
          ]
        ]
      ]
    ]
  ]
  "idiomaDefecto" => "es"
  "url" => "/02116995/0000003800000001/v1_201801090621/S0211699517301777/v1_201801090621/es/main.assets"
  "Apartado" => array:4 [
    "identificador" => "48184"
    "tipo" => "SECCION"
    "en" => array:2 [
      "titulo" => "Editoriales"
      "idiomaDefecto" => true
    ]
    "idiomaDefecto" => "en"
  ]
  "PDF" => "https://static.elsevier.es/multimedia/02116995/0000003800000001/v1_201801090621/S0211699517301777/v1_201801090621/es/main.pdf?idApp=UINPBA000064&text.app=https://revistanefrologia.com/"
  "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0211699517301777?idApp=UINPBA000064"
]
Compartir
Información de la revista

Estadísticas

Siga este enlace para acceder al texto completo del artículo

Editorial
El dializador en el año 2017: mucho más que una membrana
The dialyser in the year 2017: much more than a membrane
Rafael Pérez-García
Autor para correspondencia
, Roberto Alcázar
Servicio de Nefrología, Hospital Infanta Leonor, Madrid, España
Leído
34151
Veces
se ha leído el artículo
4638
Total PDF
29513
Total HTML
Compartir estadísticas
 array:25 [
  "pii" => "S0211699517301777"
  "issn" => "02116995"
  "doi" => "10.1016/j.nefro.2017.08.003"
  "estado" => "S300"
  "fechaPublicacion" => "2018-01-01"
  "aid" => "416"
  "copyright" => "Sociedad Espa&#241;ola de Nefrolog&#237;a"
  "copyrightAnyo" => "2017"
  "documento" => "article"
  "crossmark" => 0
  "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
  "subdocumento" => "sco"
  "cita" => "Nefrologia. 2018;38:4-7"
  "abierto" => array:3 [
    "ES" => true
    "ES2" => true
    "LATM" => true
  ]
  "gratuito" => true
  "lecturas" => array:2 [
    "total" => 13545
    "formatos" => array:3 [
      "EPUB" => 289
      "HTML" => 11745
      "PDF" => 1511
    ]
  ]
  "Traduccion" => array:1 [
    "en" => array:20 [
      "pii" => "S201325141830018X"
      "issn" => "20132514"
      "doi" => "10.1016/j.nefroe.2018.01.006"
      "estado" => "S300"
      "fechaPublicacion" => "2018-01-01"
      "aid" => "416"
      "copyright" => "Sociedad Espa&#241;ola de Nefrolog&#237;a"
      "documento" => "article"
      "crossmark" => 0
      "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
      "subdocumento" => "sco"
      "cita" => "Nefrologia &#40;English Version&#41;. 2018;38:4-7"
      "abierto" => array:3 [
        "ES" => true
        "ES2" => true
        "LATM" => true
      ]
      "gratuito" => true
      "lecturas" => array:2 [
        "total" => 8679
        "formatos" => array:3 [
          "EPUB" => 259
          "HTML" => 7235
          "PDF" => 1185
        ]
      ]
      "en" => array:11 [
        "idiomaDefecto" => true
        "cabecera" => "<span class="elsevierStyleTextfn">Editorial</span>"
        "titulo" => "The dialyser in the year 2017&#58; Much more than a membrane"
        "tienePdf" => "en"
        "tieneTextoCompleto" => "en"
        "paginas" => array:1 [
          0 => array:2 [
            "paginaInicial" => "4"
            "paginaFinal" => "7"
          ]
        ]
        "titulosAlternativos" => array:1 [
          "es" => array:1 [
            "titulo" => "El dializador en el a&#241;o 2017&#58; mucho m&#225;s que una membrana"
          ]
        ]
        "contieneTextoCompleto" => array:1 [
          "en" => true
        ]
        "contienePdf" => array:1 [
          "en" => true
        ]
        "resumenGrafico" => array:2 [
          "original" => 0
          "multimedia" => array:7 [
            "identificador" => "fig0005"
            "etiqueta" => "Fig&#46; 1"
            "tipo" => "MULTIMEDIAFIGURA"
            "mostrarFloat" => true
            "mostrarDisplay" => false
            "figura" => array:1 [
              0 => array:4 [
                "imagen" => "gr1.jpeg"
                "Alto" => 1061
                "Ancho" => 1500
                "Tamanyo" => 145186
              ]
            ]
            "descripcion" => array:1 [
              "en" => "<p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">Size and distribution of membrane pores&#46;</p> <p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">HCO&#58; high cut-off membranes&#59; HF&#58; high-flux plasma filters and dialysers&#59; MCO&#58; medium cut-off membranes&#47;intermediate pores&#59; s&#47;n&#58; standardised number of pores per each size&#44; out of one&#46;</p>"
            ]
          ]
        ]
        "autores" => array:1 [
          0 => array:2 [
            "autoresLista" => "Rafael P&#233;rez-Garc&#237;a, Roberto Alc&#225;zar"
            "autores" => array:2 [
              0 => array:2 [
                "nombre" => "Rafael"
                "apellidos" => "P&#233;rez-Garc&#237;a"
              ]
              1 => array:2 [
                "nombre" => "Roberto"
                "apellidos" => "Alc&#225;zar"
              ]
            ]
          ]
        ]
      ]
      "idiomaDefecto" => "en"
      "Traduccion" => array:1 [
        "es" => array:9 [
          "pii" => "S0211699517301777"
          "doi" => "10.1016/j.nefro.2017.08.003"
          "estado" => "S300"
          "subdocumento" => ""
          "abierto" => array:3 [
            "ES" => true
            "ES2" => true
            "LATM" => true
          ]
          "gratuito" => true
          "lecturas" => array:1 [
            "total" => 0
          ]
          "idiomaDefecto" => "es"
          "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0211699517301777?idApp=UINPBA000064"
        ]
      ]
      "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S201325141830018X?idApp=UINPBA000064"
      "url" => "/20132514/0000003800000001/v1_201802180616/S201325141830018X/v1_201802180616/en/main.assets"
    ]
  ]
  "itemSiguiente" => array:20 [
    "pii" => "S0211699517301881"
    "issn" => "02116995"
    "doi" => "10.1016/j.nefro.2017.09.004"
    "estado" => "S300"
    "fechaPublicacion" => "2018-01-01"
    "aid" => "426"
    "copyright" => "Sociedad Espa&#241;ola de Nefrolog&#237;a"
    "documento" => "article"
    "crossmark" => 0
    "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
    "subdocumento" => "fla"
    "cita" => "Nefrologia. 2018;38:8-12"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 73975
      "formatos" => array:3 [
        "EPUB" => 441
        "HTML" => 64075
        "PDF" => 9459
      ]
    ]
    "es" => array:13 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Art&#237;culo especial</span>"
      "titulo" => "Anemia en la enfermedad renal cr&#243;nica&#58; protocolo de estudio&#44; manejo y derivaci&#243;n a Nefrolog&#237;a"
      "tienePdf" => "es"
      "tieneTextoCompleto" => "es"
      "tieneResumen" => array:2 [
        0 => "es"
        1 => "en"
      ]
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "8"
          "paginaFinal" => "12"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "en" => array:1 [
          "titulo" => "Anemia of chronic kidney disease&#58; Protocol of study&#44; management and referral to Nephrology"
        ]
      ]
      "contieneResumen" => array:2 [
        "es" => true
        "en" => true
      ]
      "contieneTextoCompleto" => array:1 [
        "es" => true
      ]
      "contienePdf" => array:1 [
        "es" => true
      ]
      "resumenGrafico" => array:2 [
        "original" => 0
        "multimedia" => array:7 [
          "identificador" => "fig0005"
          "etiqueta" => "Figura 1"
          "tipo" => "MULTIMEDIAFIGURA"
          "mostrarFloat" => true
          "mostrarDisplay" => false
          "figura" => array:1 [
            0 => array:4 [
              "imagen" => "gr1.jpeg"
              "Alto" => 1919
              "Ancho" => 2531
              "Tamanyo" => 422101
            ]
          ]
          "descripcion" => array:1 [
            "es" => "<p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">Algoritmo de estudio y remisi&#243;n a Nefrolog&#237;a por anemia de origen renal&#46;</p>"
          ]
        ]
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "Aleix Cases, M&#46; Isabel Egocheaga, Salvador Tranche, Vicente Pallar&#233;s, Raquel Ojeda, Jos&#233; Luis G&#243;rriz, Jos&#233; Mar&#237;a Portol&#233;s"
          "autores" => array:7 [
            0 => array:2 [
              "nombre" => "Aleix"
              "apellidos" => "Cases"
            ]
            1 => array:2 [
              "nombre" => "M&#46; Isabel"
              "apellidos" => "Egocheaga"
            ]
            2 => array:2 [
              "nombre" => "Salvador"
              "apellidos" => "Tranche"
            ]
            3 => array:2 [
              "nombre" => "Vicente"
              "apellidos" => "Pallar&#233;s"
            ]
            4 => array:2 [
              "nombre" => "Raquel"
              "apellidos" => "Ojeda"
            ]
            5 => array:2 [
              "nombre" => "Jos&#233; Luis"
              "apellidos" => "G&#243;rriz"
            ]
            6 => array:2 [
              "nombre" => "Jos&#233; Mar&#237;a"
              "apellidos" => "Portol&#233;s"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "es"
    "Traduccion" => array:1 [
      "en" => array:9 [
        "pii" => "S2013251418300191"
        "doi" => "10.1016/j.nefroe.2018.01.007"
        "estado" => "S300"
        "subdocumento" => ""
        "abierto" => array:3 [
          "ES" => true
          "ES2" => true
          "LATM" => true
        ]
        "gratuito" => true
        "lecturas" => array:1 [
          "total" => 0
        ]
        "idiomaDefecto" => "en"
        "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2013251418300191?idApp=UINPBA000064"
      ]
    ]
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0211699517301881?idApp=UINPBA000064"
    "url" => "/02116995/0000003800000001/v1_201801090621/S0211699517301881/v1_201801090621/es/main.assets"
  ]
  "itemAnterior" => array:20 [
    "pii" => "S021169951730142X"
    "issn" => "02116995"
    "doi" => "10.1016/j.nefro.2017.06.005"
    "estado" => "S300"
    "fechaPublicacion" => "2018-01-01"
    "aid" => "407"
    "copyright" => "Sociedad Espa&#241;ola de Nefrolog&#237;a"
    "documento" => "article"
    "crossmark" => 0
    "licencia" => "http://creativecommons.org/licenses/by-nc-nd/4.0/"
    "subdocumento" => "sco"
    "cita" => "Nefrologia. 2018;38:1-3"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 8556
      "formatos" => array:3 [
        "EPUB" => 361
        "HTML" => 7086
        "PDF" => 1109
      ]
    ]
    "es" => array:10 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Editorial</span>"
      "titulo" => "Seguridad en hemodi&#225;lisis&#58; paradigma del trabajo en equipo"
      "tienePdf" => "es"
      "tieneTextoCompleto" => "es"
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "1"
          "paginaFinal" => "3"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "en" => array:1 [
          "titulo" => "Safety on haemodialysis&#58; Team work paradigm"
        ]
      ]
      "contieneTextoCompleto" => array:1 [
        "es" => true
      ]
      "contienePdf" => array:1 [
        "es" => true
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "M&#46; Dolores Arenas Jim&#233;nez, Manuel Mac&#237;a-Heras"
          "autores" => array:2 [
            0 => array:2 [
              "nombre" => "M&#46; Dolores"
              "apellidos" => "Arenas Jim&#233;nez"
            ]
            1 => array:2 [
              "nombre" => "Manuel"
              "apellidos" => "Mac&#237;a-Heras"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "es"
    "Traduccion" => array:1 [
      "en" => array:9 [
        "pii" => "S2013251418300178"
        "doi" => "10.1016/j.nefroe.2018.01.005"
        "estado" => "S300"
        "subdocumento" => ""
        "abierto" => array:3 [
          "ES" => true
          "ES2" => true
          "LATM" => true
        ]
        "gratuito" => true
        "lecturas" => array:1 [
          "total" => 0
        ]
        "idiomaDefecto" => "en"
        "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2013251418300178?idApp=UINPBA000064"
      ]
    ]
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S021169951730142X?idApp=UINPBA000064"
    "url" => "/02116995/0000003800000001/v1_201801090621/S021169951730142X/v1_201801090621/es/main.assets"
  ]
  "es" => array:14 [
    "idiomaDefecto" => true
    "cabecera" => "<span class="elsevierStyleTextfn">Editorial</span>"
    "titulo" => "El dializador en el a&#241;o 2017&#58; mucho m&#225;s que una membrana"
    "tieneTextoCompleto" => true
    "paginas" => array:1 [
      0 => array:2 [
        "paginaInicial" => "4"
        "paginaFinal" => "7"
      ]
    ]
    "autores" => array:1 [
      0 => array:4 [
        "autoresLista" => "Rafael P&#233;rez-Garc&#237;a, Roberto Alc&#225;zar"
        "autores" => array:2 [
          0 => array:4 [
            "nombre" => "Rafael"
            "apellidos" => "P&#233;rez-Garc&#237;a"
            "email" => array:2 [
              0 => "rperezgarcia&#64;senefro&#46;org"
              1 => "cerperezga&#64;salud&#46;madrid&#46;org"
            ]
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">&#42;</span>"
                "identificador" => "cor0005"
              ]
            ]
          ]
          1 => array:2 [
            "nombre" => "Roberto"
            "apellidos" => "Alc&#225;zar"
          ]
        ]
        "afiliaciones" => array:1 [
          0 => array:2 [
            "entidad" => "Servicio de Nefrolog&#237;a&#44; Hospital Infanta Leonor&#44; Madrid&#44; Espa&#241;a"
            "identificador" => "aff0005"
          ]
        ]
        "correspondencia" => array:1 [
          0 => array:3 [
            "identificador" => "cor0005"
            "etiqueta" => "&#8270;"
            "correspondencia" => "Autor para correspondencia&#46;"
          ]
        ]
      ]
    ]
    "titulosAlternativos" => array:1 [
      "en" => array:1 [
        "titulo" => "The dialyser in the year 2017&#58; much more than a membrane"
      ]
    ]
    "resumenGrafico" => array:2 [
      "original" => 0
      "multimedia" => array:7 [
        "identificador" => "fig0005"
        "etiqueta" => "Figura 1"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr1.jpeg"
            "Alto" => 1061
            "Ancho" => 1500
            "Tamanyo" => 153710
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">Tama&#241;o y distribuci&#243;n de los poros de las membranas&#46;</p> <p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">HCO&#58; membranas de alto punto de corte&#59; HF&#58; plasmafiltros y dializadores de alta eficacia&#59; MCO&#58; membranas de punto de corte medio&#47;poros intermedios&#59; n&#47;no&#58; n&#250;mero de poros de cada tama&#241;o normalizado en tanto por uno&#46;</p>"
        ]
      ]
    ]
    "textoCompleto" => "<span class="elsevierStyleSections"><p id="par0005" class="elsevierStylePara elsevierViewall">El dializador es el elemento central de la hemodi&#225;lisis&#44; donde se producen el intercambio de sustancias entre la sangre y el l&#237;quido de di&#225;lisis &#40;LD&#41;&#59; la ultrafiltraci&#243;n &#40;UF&#41; y la retrofiltraci&#243;n&#46; Desde las primeras di&#225;lisis con dializadores tubulares de colodi&#243;n&#44; trinitrato de celulosa&#44; conocido como dializador de Haas&#44; en 1924<a class="elsevierStyleCrossRef" href="#bib0145"><span class="elsevierStyleSup">1</span></a>&#44; la hemodi&#225;lisis y los dializadores han evolucionado enormemente&#46; En esta revisi&#243;n nos vamos a centrar en los cambios de los dializadores que han aparecido en las dos &#250;ltimas d&#233;cadas&#44; que puede que no sean tan evidentes&#46;</p><p id="par0010" class="elsevierStylePara elsevierViewall">Un dializador es m&#225;s que una membrana&#44; pero est&#225; claro que esta es uno de sus componentes fundamentales&#46; Los poros de la membrana de un dializador deben ser de un tama&#241;o determinado&#44; numerosos y uniformes&#46; Esto se consigue con la nanotecnolog&#237;a<a class="elsevierStyleCrossRef" href="#bib0150"><span class="elsevierStyleSup">2</span></a>&#46; La formaci&#243;n de una capa proteica en la membrana&#44; al ponerse en contacto con la sangre&#44; restringe la eliminaci&#243;n de mol&#233;culas&#44; modificando funcionalmente los poros<a class="elsevierStyleCrossRef" href="#bib0155"><span class="elsevierStyleSup">3</span></a>&#46; De la aplicaci&#243;n de la nanotecnolog&#237;a van a depender varias de las especificaciones que se mencionan a continuaci&#243;n&#46;</p><p id="par0015" class="elsevierStylePara elsevierViewall">El coeficiente de ultrafiltraci&#243;n &#40;CUF&#41; de un dializador es una de las caracter&#237;sticas que m&#225;s se valoran&#46; El CUF y el dise&#241;o del dializador van a condicionar la retrofiltraci&#243;n&#44; que no debe generar ninguna preocupaci&#243;n con un LD ultrapuro<a class="elsevierStyleCrossRef" href="#bib0160"><span class="elsevierStyleSup">4</span></a>&#44; requisito imprescindible hoy en d&#237;a&#46; De hecho&#44; es una forma de eliminar mol&#233;culas medias y grandes sin tener que recurrir a la hemodiafiltraci&#243;n &#40;HDF&#41;&#46; Un CUF alto&#44; mayor de 40<span class="elsevierStyleHsp" style=""></span>ml&#47;mmHg&#47;h&#44; es un requisito de un dializador moderno&#46;</p><p id="par0020" class="elsevierStylePara elsevierViewall">El coeficiente de cribado &#40;CC&#41; debe ser alto para mol&#233;culas medias&#44; sin p&#233;rdidas significativas de alb&#250;mina&#46; En la hemodi&#225;lisis moderna necesitamos marcadores de eliminaci&#243;n de mol&#233;culas medias y grandes&#46; El m&#225;s utilizado es el CC para la &#946;2 microglobulina&#44; que deber&#237;a ser mayor de 0&#44;6 para el grupo EUDIAL<a class="elsevierStyleCrossRef" href="#bib0165"><span class="elsevierStyleSup">5</span></a>&#46; En la mayor&#237;a de los dializadores modernos es superior a 0&#44;7&#46; El CUF depende del n&#250;mero de poros y del CC para la &#946;2 microglobulina&#44; de su tama&#241;o y uniformidad&#46; Lo anterior debe ser compatible con una m&#237;nima eliminaci&#243;n de alb&#250;mina&#44; con un CC menor de 0&#44;01&#46; La p&#233;rdida de alb&#250;mina hay que valorarla al inicio de la sesi&#243;n y cuando se somete el dializador a presiones transmembrana elevadas&#44; como ocurre en la hemodiafiltraci&#243;n en l&#237;nea &#40;HDF-OL&#41;&#46; En estas condiciones la p&#233;rdida de alb&#250;mina deber&#237;a ser menor de 4<span class="elsevierStyleHsp" style=""></span>g por sesi&#243;n<a class="elsevierStyleCrossRef" href="#bib0170"><span class="elsevierStyleSup">6</span></a>&#46;</p><p id="par0025" class="elsevierStylePara elsevierViewall">La distribuci&#243;n del LD debe ser uniforme en el dializador&#44; no debe haber circuitos preferenciales&#44; que eviten el contacto con los capilares&#46; Esto se mejor&#243; incluyendo filamentos intercalados&#44; ondulando las fibras y mediante otros artificios&#46; Actualmente se logra con una densidad de fibras muy alta&#44; superior a 11&#46;000&#46; Con estos dializadores el flujo del LD &#40;Qd&#41; &#243;ptimo en hemodi&#225;lisis y HDF-OL est&#225; entre 400 y 500<span class="elsevierStyleHsp" style=""></span>ml&#47;min<a class="elsevierStyleCrossRefs" href="#bib0175"><span class="elsevierStyleSup">7-9</span></a> y no tiene justificaci&#243;n utilizar un Qd de 700 a 1&#46;000<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#46;</p><p id="par0030" class="elsevierStylePara elsevierViewall">La eliminaci&#243;n de agua y solutos de peque&#241;o peso molecular ha obligado a mantener una cierta hidrofilia en la membrana&#46; Esto en las membranas sint&#233;ticas se logra mediante la polivinilpirrolidona &#40;PVP&#41;&#46; Este compuesto est&#225; en las membranas sint&#233;ticas hidr&#243;fobas en mayor o menor cantidad y m&#225;s o menos imbuido en la membrana&#46; Su aparici&#243;n en el eluido podr&#237;a estar en relaci&#243;n con las reacciones al&#233;rgicas que presentan actualmente algunos pacientes con las membranas sint&#233;ticas<a class="elsevierStyleCrossRefs" href="#bib0190"><span class="elsevierStyleSup">10&#44;11</span></a>&#46; El aspecto cl&#237;nico m&#225;s evidente de la bioincompatibilidad de los dializadores son las reacciones adversas&#46; Estas reacciones adversas se denominan habitualmente como reacciones de hipersensibilidad tipos A y B&#46; Actualmente creemos que es m&#225;s &#250;til definirlas por su cl&#237;nica y causa&#46; Ha habido reacciones por degranulaci&#243;n de los bas&#243;filos espec&#237;fica o inespec&#237;fica al &#243;xido de etileno &#40;ETO&#41;&#44; activaci&#243;n del complemento por el cuprof&#225;n y otras membranas celul&#243;sicas&#44; reacciones al AN-69 junto con los IECA&#44; entre otras&#46; En los &#250;ltimos a&#241;os asistimos a reacciones en algunos pacientes con el uso de membranas sint&#233;ticas con PVP&#44; que dejan de aparecer al cambiarlos a dializadores de triacetato de celulosa<a class="elsevierStyleCrossRefs" href="#bib0200"><span class="elsevierStyleSup">12&#44;13</span></a>&#46; En la actualidad contamos con dializadores de triacetato de celulosa asim&#233;trico de alto flujo&#44; con un CUF de 87<span class="elsevierStyleHsp" style=""></span>ml&#47;mmHg&#47;h y grandes prestaciones en HDF-OL<a class="elsevierStyleCrossRef" href="#bib0210"><span class="elsevierStyleSup">14</span></a>&#46; Los nuevos dializadores deben solucionar estas interacciones con la sangre&#44; ejemplo de ello ha sido la no esterilizaci&#243;n de los dializadores con ETO&#46; Tambi&#233;n&#44; los materiales de la carcasa del dializador y los necesarios para el ensamblaje pueden desencadenar reacciones adversas o toxicidad&#46; Por &#250;ltimo se deber&#237;an eliminar otras sustancias t&#243;xicas&#44; como el bisfenol &#40;BPA&#41;<a class="elsevierStyleCrossRefs" href="#bib0215"><span class="elsevierStyleSup">15&#44;16</span></a>&#46;</p><p id="par0035" class="elsevierStylePara elsevierViewall">En los &#250;ltimos a&#241;os los dializadores se han ido especializando en funci&#243;n de la t&#233;cnica de di&#225;lisis&#46; Los de alto punto de corte &#40;HCO&#41;&#44; poros grandes&#44; para eliminar la mayor cantidad de mol&#233;culas como las cadenas ligeras de las inmunoglobulinas en el tratamiento del ri&#241;&#243;n de mieloma<a class="elsevierStyleCrossRefs" href="#bib0225"><span class="elsevierStyleSup">17&#44;18</span></a>&#46; Recientemente se han desarrollado membranas&#44; de punto de corte medio &#40;MCO&#41; &#40;<a class="elsevierStyleCrossRef" href="#fig0005">fig&#46; 1</a>&#41;&#44; con capacidad de eliminaci&#243;n de mol&#233;culas como las HCO&#44; pero capaces de retener la alb&#250;mina &#40;<a class="elsevierStyleCrossRef" href="#fig0010">fig&#46; 2</a>&#41;<a class="elsevierStyleCrossRef" href="#bib0155"><span class="elsevierStyleSup">3</span></a>&#46; Con estos dializadores se puede obtener una depuraci&#243;n de mol&#233;culas medias superior que con los dializadores de alta eficacia &#40;<span class="elsevierStyleItalic">high-flux</span> &#91;HF&#93;&#41;<a class="elsevierStyleCrossRef" href="#bib0235"><span class="elsevierStyleSup">19</span></a>&#46;</p><elsevierMultimedia ident="fig0005"></elsevierMultimedia><elsevierMultimedia ident="fig0010"></elsevierMultimedia><p id="par0040" class="elsevierStylePara elsevierViewall">Por otro lado&#44; se han dise&#241;ado dializadores para aprovechar la retrofiltraci&#243;n&#44; como forma de depuraci&#243;n por trasporte convectivo interno<a class="elsevierStyleCrossRef" href="#bib0240"><span class="elsevierStyleSup">20</span></a>&#44; lo que se ha denominado hemodiafiltraci&#243;n interna &#40;HDFi&#41;<a class="elsevierStyleCrossRef" href="#bib0245"><span class="elsevierStyleSup">21</span></a>&#46; Una de las formas de aumentar la HDFi es aumentar la densidad de los capilares&#44; &#8805;<span class="elsevierStyleHsp" style=""></span>74&#37;&#44; logrando una HDFi de 3&#44;5<span class="elsevierStyleHsp" style=""></span>l&#47;h<a class="elsevierStyleCrossRef" href="#bib0250"><span class="elsevierStyleSup">22</span></a>&#46; Otra forma es disminuir el di&#225;metro interno de los capilares para aumentar las resistencias internas y lograr mayor retrofiltraci&#243;n&#46; En esa disminuci&#243;n por debajo de 200<span class="elsevierStyleHsp" style=""></span>&#956;m se ha llegado hasta las 180<span class="elsevierStyleHsp" style=""></span>&#956; de di&#225;metro&#44; como en el dializador Theranova&#8482;&#46; Hay que recordar que el radio interno del capilar figura a la cuarta potencia en la ecuaci&#243;n de Hagen-Poiseuille para calcular la resistencia de la sangre al paso por los capilares&#46; Un dializador largo&#44; estrecho y con un di&#225;metro de los capilares de 185-180<span class="elsevierStyleHsp" style=""></span>&#956;m va a provocar una ca&#237;da de presi&#243;n dentro del capilar muy grande&#44; de alrededor de 200<span class="elsevierStyleHsp" style=""></span>mmHg para 500 de Qb&#46; Este dise&#241;o ser&#237;a el ideal para un dializador para una hemodi&#225;lisis de muy alta eficacia&#44; en ingl&#233;s de HD-VHF&#46; Estos dializadores no se recomiendan para HDF-OL&#46; En HDF-OL se recomiendan dializadores con un di&#225;metro interno de los capilares igual o mayor de 200<span class="elsevierStyleHsp" style=""></span>&#956;m&#46; As&#237; la empresa Fresenius &#40;FMC&#8482;&#41; cre&#243; una l&#237;nea de dializadores FXclass<span class="elsevierStyleSup">&#174;</span> espec&#237;fica&#44; como el Fx800<span class="elsevierStyleSup">&#174;</span>&#44; distinto del Fx80<span class="elsevierStyleSup">&#174;</span>&#46; En este n&#250;mero de <span class="elsevierStyleSmallCaps">Nefrolog&#237;a</span> se publica un estudio en el que el Dr&#46; Maduell et al&#46;<a class="elsevierStyleCrossRef" href="#bib0255"><span class="elsevierStyleSup">23</span></a> demuestran unas tasas de reducci&#243;n de mol&#233;culas peque&#241;as y medianas semejantes en HDF-OL posdilucional con autosustituci&#243;n<span class="elsevierStyleSup">&#174;</span> comparando dializadores FX60 vs&#46; FX600 y FX80 vs&#46; FX800&#46; En HDF-OL la eliminaci&#243;n de mol&#233;culas medias depende fundamentalmente del volumen ultrafiltrado y del CC de cada mol&#233;cula&#46; Con los dos tipos de dializadores consiguen una depuraci&#243;n semejante&#46; El trabajo est&#225; realizado en condiciones &#243;ptimas&#44; Qb 450<span class="elsevierStyleHsp" style=""></span>ml&#47;min&#44; 283<span class="elsevierStyleHsp" style=""></span>min de sesi&#243;n con una media de 32&#44;5<span class="elsevierStyleHsp" style=""></span>l de UF por sesi&#243;n&#46; Lo anterior significa una fracci&#243;n de filtraci&#243;n media del 25&#44;5&#37;&#44; no muy alta&#44; y con un hematocrito medio del 29&#37;&#46; Los dializadores que se recomiendan para HDF-OL posdilucional est&#225;n dise&#241;ados no para lograr m&#225;s volumen de UF y mayor eliminaci&#243;n de mol&#233;culas&#44; sino para evitar las complicaciones propias de la hemoconcentraci&#243;n en situaciones menos favorables y con fracciones de filtraci&#243;n mayores&#44; de alrededor del 30&#37;&#46; Nosotros publicamos un trabajo<a class="elsevierStyleCrossRef" href="#bib0260"><span class="elsevierStyleSup">24</span></a> comparando en HDF-OL posdilucional 4 dializadores&#58; FX1000<span class="elsevierStyleSup">&#174;</span>&#44; FX800<span class="elsevierStyleSup">&#174;</span>&#44; Polyflux 210H<span class="elsevierStyleSup">&#174;</span> y Elisio 210H<span class="elsevierStyleSup">&#174;</span>&#46; Los 3 primeros con un dise&#241;o para HDF-OL y el &#250;ltimo para HD-HF&#46; La tasa de reducci&#243;n de la concentraci&#243;n de las mol&#233;culas evaluadas fue semejante con los 4 dializadores&#44; as&#237; como el volumen ultrafiltrado&#46; La diferencia estuvo en el n&#250;mero de alarmas&#47;problemas que aparecieron en la m&#225;quina de di&#225;lisis con el Elisio<span class="elsevierStyleSup">&#174;</span>&#44; lo que se debi&#243; a un aumento de la presi&#243;n predializador superior en m&#225;s de 100<span class="elsevierStyleHsp" style=""></span>mmHg respecto a los otros 3 dializadores&#46; En este trabajo los Qb eran menores y 3 pacientes ten&#237;an un cat&#233;ter como acceso vascular&#46; La selecci&#243;n de los dializadores id&#243;neos para HDF-OL ya ha sido abordada<a class="elsevierStyleCrossRefs" href="#bib0265"><span class="elsevierStyleSup">25&#44;26</span></a>&#46; Por tanto&#44; no se pueden extrapolar las conclusiones del trabajo de Maduell et al&#46; en condiciones de di&#225;lisis menos &#243;ptimas&#46;</p><p id="par0045" class="elsevierStylePara elsevierViewall">Tambi&#233;n se ha avanzado en la capacidad de adsorci&#243;n de algunas membranas&#44; como el PMMA&#44; disminuyendo su capacidad de activar las plaquetas y su trombogenicidad<a class="elsevierStyleCrossRef" href="#bib0275"><span class="elsevierStyleSup">27</span></a>&#46; En otros se ha aprovechado esa capacidad adsortiva para injertar heparina y disminuir la trombogenicidad<a class="elsevierStyleCrossRef" href="#bib0280"><span class="elsevierStyleSup">28</span></a>&#46; Su asociaci&#243;n a un LD con citrato logra resultados prometedores evitando tener que utilizar anticoagulaci&#243;n en la HD<a class="elsevierStyleCrossRef" href="#bib0280"><span class="elsevierStyleSup">28</span></a>&#46;</p><p id="par0050" class="elsevierStylePara elsevierViewall">Otros aspectos a tener en cuenta en el dializador son&#58; el volumen en el compartimento sangu&#237;neo&#44; siendo &#243;ptimo por debajo &#60;<span class="elsevierStyleHsp" style=""></span>120<span class="elsevierStyleHsp" style=""></span>ml&#44; para 2<span class="elsevierStyleHsp" style=""></span>m<span class="elsevierStyleSup">2</span> y volumen de sangre residual &#60;<span class="elsevierStyleHsp" style=""></span>1<span class="elsevierStyleHsp" style=""></span>ml&#46; La superficie del dializador deber&#237;a estar en funci&#243;n del Qb que se alcanza&#46; La esterilizaci&#243;n&#58; el ETO se ha ido desterrando como m&#233;todo de esterilizaci&#243;n de los dializadores&#46; El vapor de agua y la radiaci&#243;n gamma son los m&#233;todos m&#225;s frecuentes actualmente&#46; Cuando valoremos los datos de un dializador&#44; debemos comprobar que las pruebas in vitro deben atenerse a especificaciones est&#225;ndar&#44; como la ISO 8637&#58; 2014&#46;</p><p id="par0055" class="elsevierStylePara elsevierViewall">En la <a class="elsevierStyleCrossRef" href="#tbl0005">tabla 1</a> se enumeran las caracter&#237;sticas que nos deben orientar en la elecci&#243;n de un dializador para una t&#233;cnica de di&#225;lisis y un paciente en concreto&#46; Algunas de esas caracter&#237;sticas se pueden considerar como criterios de calidad de un dializador&#46;</p><elsevierMultimedia ident="tbl0005"></elsevierMultimedia><p id="par0060" class="elsevierStylePara elsevierViewall">Los avances tecnol&#243;gicos han permitido que los dializadores hayan evolucionado enormemente en los &#250;ltimos a&#241;os&#44; consiguiendo que la hemodi&#225;lisis sea m&#225;s eficaz&#44; m&#225;s eficiente y m&#225;s segura&#46; Al igual que estamos individualizando la prescripci&#243;n del LD&#44; la tendencia actual es la de adecuar la elecci&#243;n del dializador a la t&#233;cnica y a las caracter&#237;sticas del acceso vascular de cada paciente&#46; Se est&#225; mejorando y se tiene que mejorar todav&#237;a m&#225;s en la biocompatibilidad de las membranas y dializadores para disminuir el riesgo de efectos adversos&#46;</p><p id="par0065" class="elsevierStylePara elsevierViewall">Los poros funcionalmente se modifican por varios factores&#44; fundamentalmente por el contacto con la sangre y por la presi&#243;n a la que se somete la membrana&#46;</p><span id="sec0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0005">Puntos clave</span><p id="par0070" class="elsevierStylePara elsevierViewall"><ul class="elsevierStyleList" id="lis0005"><li class="elsevierStyleListItem" id="lsti0005"><span class="elsevierStyleLabel">1&#46;</span><p id="par0075" class="elsevierStylePara elsevierViewall">Los avances tecnol&#243;gicos en los dializadores permiten&#44; hoy d&#237;a&#44; individualizar la elecci&#243;n del dializador a la t&#233;cnica y a las caracter&#237;sticas del acceso vascular en cada paciente&#46;</p></li><li class="elsevierStyleListItem" id="lsti0010"><span class="elsevierStyleLabel">2&#46;</span><p id="par0080" class="elsevierStylePara elsevierViewall">De la hemodi&#225;lisis de alto flujo &#40;HF&#41; debemos pasar a la hemodiafiltraci&#243;n interna &#40;HDFi&#41;&#46; La HDFi no se debe considerar un competidor de la hemodiafiltraci&#243;n en l&#237;nea &#40;HDF-OL&#41;&#44; ser&#237;a una alternativa para aplicar las ventajas del trasporte convectivo a pacientes no susceptibles de HDF-OL&#44; implicar&#237;a menos requerimientos t&#233;cnicos y un menor coste&#46; Est&#225;n por demostrar sus beneficios a nivel cl&#237;nico&#46;</p></li><li class="elsevierStyleListItem" id="lsti0015"><span class="elsevierStyleLabel">3&#46;</span><p id="par0085" class="elsevierStylePara elsevierViewall">La HDF-OL en situaciones no &#243;ptimas y con fracciones de filtraci&#243;n del 30&#37; precisan de dializadores espec&#237;ficos&#46;</p></li><li class="elsevierStyleListItem" id="lsti0020"><span class="elsevierStyleLabel">4&#46;</span><p id="par0090" class="elsevierStylePara elsevierViewall">Los dializadores actuales deben evitar las reacciones adversas&#44; incluyendo las reacciones de hipersensibilidad y t&#243;xicas&#46; Deben seguir mejorando su biocompatibilidad&#46;</p></li><li class="elsevierStyleListItem" id="lsti0025"><span class="elsevierStyleLabel">5&#46;</span><p id="par0095" class="elsevierStylePara elsevierViewall">En la HDFi y en la HDF-OL las p&#233;rdidas de alb&#250;mina deben ser peque&#241;as&#44; en todo caso con coeficientes de cribado &#40;CC&#41; menores de 0&#44;01 y menores de 4<span class="elsevierStyleHsp" style=""></span>g por sesi&#243;n&#46;</p></li></ul></p></span></span>"
    "textoCompletoSecciones" => array:1 [
      "secciones" => array:2 [
        0 => array:2 [
          "identificador" => "sec0005"
          "titulo" => "Puntos clave"
        ]
        1 => array:1 [
          "titulo" => "Bibliograf&#237;a"
        ]
      ]
    ]
    "pdfFichero" => "main.pdf"
    "tienePdf" => true
    "multimedia" => array:3 [
      0 => array:7 [
        "identificador" => "fig0005"
        "etiqueta" => "Figura 1"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr1.jpeg"
            "Alto" => 1061
            "Ancho" => 1500
            "Tamanyo" => 153710
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">Tama&#241;o y distribuci&#243;n de los poros de las membranas&#46;</p> <p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">HCO&#58; membranas de alto punto de corte&#59; HF&#58; plasmafiltros y dializadores de alta eficacia&#59; MCO&#58; membranas de punto de corte medio&#47;poros intermedios&#59; n&#47;no&#58; n&#250;mero de poros de cada tama&#241;o normalizado en tanto por uno&#46;</p>"
        ]
      ]
      1 => array:7 [
        "identificador" => "fig0010"
        "etiqueta" => "Figura 2"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr2.jpeg"
            "Alto" => 1544
            "Ancho" => 2500
            "Tamanyo" => 410989
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">Microfotograf&#237;a de la cara interna de los 4 tipos de membranas en funci&#243;n del tama&#241;o de los poros&#58; A&#41; alta eficacia &#40;HF&#41;&#59; B&#41; punto de corte medio &#40;MCO&#41; &#40;Theranova<span class="elsevierStyleSup">&#174;</span>&#41;&#59; C&#41; alto punto de corte &#40;HCO&#41;&#59; D&#41; plasmafiltro&#46; Magnificaci&#243;n 60&#46;000&#215;&#46;</p>"
        ]
      ]
      2 => array:8 [
        "identificador" => "tbl0005"
        "etiqueta" => "Tabla 1"
        "tipo" => "MULTIMEDIATABLA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "detalles" => array:1 [
          0 => array:3 [
            "identificador" => "at1"
            "detalle" => "Tabla "
            "rol" => "short"
          ]
        ]
        "tabla" => array:1 [
          "tablatextoimagen" => array:1 [
            0 => array:2 [
              "tabla" => array:1 [
                0 => """
                  <table border="0" frame="\n
                  \t\t\t\t\tvoid\n
                  \t\t\t\t" class=""><tbody title="tbody"><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">1&#46; CUF alto&#44; &#62;<span class="elsevierStyleHsp" style=""></span>40<span class="elsevierStyleHsp" style=""></span>ml&#47;mmHg&#47;h&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">2&#46; Coeficiente de cribado para la &#946;2 microglobulina &#62;<span class="elsevierStyleHsp" style=""></span>0&#44;7&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">3&#46; Coeficiente de cribado &#60;<span class="elsevierStyleHsp" style=""></span>0&#44;01 para la alb&#250;mina&#46; En HDF-OL la p&#233;rdida de alb&#250;mina por sesi&#243;n deber&#237;a ser &#60;<span class="elsevierStyleHsp" style=""></span>4<span class="elsevierStyleHsp" style=""></span>g&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">4&#46; Alta densidad de empaquetado de los capilares&#44; &#62;<span class="elsevierStyleHsp" style=""></span>11&#46;000&#44; que permita dializar con Qd entre 400 y 500<span class="elsevierStyleHsp" style=""></span>ml&#47;min con buen rendimiento&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">5&#46; Altas resistencias internas en hemodi&#225;lisis&#44; dializadores largos y con di&#225;metro interno de los capilares &#60;<span class="elsevierStyleHsp" style=""></span>200<span class="elsevierStyleHsp" style=""></span>&#956;m&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">6&#46; En HDF-OL posdilucional&#44; si se funciona con Qb limitados&#44; Hto&#46; alto&#44; FF &#8764;<span class="elsevierStyleHsp" style=""></span>30&#37;&#44; dializadores con &#62;<span class="elsevierStyleHsp" style=""></span>200<span class="elsevierStyleHsp" style=""></span>&#956;m de di&#225;metro interno de los capilares&#46; Presi&#243;n prefiltro &#60;<span class="elsevierStyleHsp" style=""></span>700<span class="elsevierStyleHsp" style=""></span>mmHg&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">7&#46; Esterilizaci&#243;n libre de ETO&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td-with-role" title="table-entry ; entry_with_role_rowhead " align="left" valign="top">8&#46; Buena biocompatibilidad&#46; Recomendable&#44; libre de BPA y otros t&#243;xicos y no reacciones adversas&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr></tbody></table>
                  """
              ]
              "imagenFichero" => array:1 [
                0 => "xTab1639257.png"
              ]
            ]
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p id="spar0020" class="elsevierStyleSimplePara elsevierViewall">Caracter&#237;sticas de un dializador recomendables para realizar una hemodi&#225;lisis o hemodiafiltraci&#243;n actual &#243;ptima</p>"
        ]
      ]
    ]
    "bibliografia" => array:2 [
      "titulo" => "Bibliograf&#237;a"
      "seccion" => array:1 [
        0 => array:2 [
          "identificador" => "bibs0015"
          "bibliografiaReferencia" => array:28 [
            0 => array:3 [
              "identificador" => "bib0145"
              "etiqueta" => "1"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Versuche der Blutauswaschung am Lebenden mit Hilfe der Dialyse"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:1 [
                            0 => "G&#46; Haas"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:4 [
                        "tituloSerie" => "Klin Woechenschrift&#44;"
                        "fecha" => "1925"
                        "volumen" => "4"
                        "paginaInicial" => "13"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            1 => array:3 [
              "identificador" => "bib0150"
              "etiqueta" => "2"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Hemodialysis membranes for high-volume hemodialytic therapies&#58; The application of nanotechnology"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "C&#46; Ronco"
                            1 => "B&#46; Breuer"
                            2 => "S&#46;K&#46; Bowry"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Hemodial Int&#46;"
                        "fecha" => "2006"
                        "volumen" => "10"
                        "paginaInicial" => "48"
                        "paginaFinal" => "50"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            2 => array:3 [
              "identificador" => "bib0155"
              "etiqueta" => "3"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "MCO membranes&#58; Enhances selectivity in high-flux class"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:4 [
                            0 => "A&#46; Boschetti-de-Fierro"
                            1 => "M&#46; Voigt"
                            2 => "M&#46; Storr"
                            3 => "B&#46; Krause"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1038/srep18448"
                      "Revista" => array:5 [
                        "tituloSerie" => "Sci Rep&#46;"
                        "fecha" => "2015"
                        "volumen" => "5"
                        "paginaInicial" => "18448"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26669756"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            3 => array:3 [
              "identificador" => "bib0160"
              "etiqueta" => "4"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Gu&#237;a de gesti&#243;n de calidad del l&#237;quido de di&#225;lisis &#40;LD&#41; &#40;segunda edici&#243;n&#44; 2015&#41;"
                      "autores" => array:1 [
                        0 => array:3 [
                          "colaboracion" => "Comisi&#243;n de Expertos de la Sociedad Espa&#241;ola de Nefrolog&#237;a para la creaci&#243;n de la segunda edici&#243;n de la Gu&#237;a de gesti&#243;n de calidad del l&#237;quido de di&#225;lisis"
                          "etal" => true
                          "autores" => array:6 [
                            0 => "R&#46; P&#233;rez-Garc&#237;a"
                            1 => "R&#46; Garc&#237;a Maset"
                            2 => "E&#46; Gonzalez Parra"
                            3 => "C&#46; Soloz&#225;bal Campos"
                            4 => "R&#46; Ram&#237;rez Chamond"
                            5 => "P&#46; Mart&#237;n-Rabad&#225;n"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.nefro.2016.01.003"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nefrolog&#237;a&#46;"
                        "fecha" => "2016"
                        "volumen" => "36"
                        "paginaInicial" => "e1"
                        "paginaFinal" => "e52"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26988922"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            4 => array:3 [
              "identificador" => "bib0165"
              "etiqueta" => "5"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Online haemodiafiltration&#58; Definition&#44; dose quantification and safety revisited"
                      "autores" => array:1 [
                        0 => array:3 [
                          "colaboracion" => "EUDIAL group"
                          "etal" => false
                          "autores" => array:2 [
                            0 => "J&#46;E&#46; Tattersall"
                            1 => "R&#46;A&#46; Ward"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1093/ndt/gfs530"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nephrol Dial Transplant&#46;"
                        "fecha" => "2013"
                        "volumen" => "28"
                        "paginaInicial" => "542"
                        "paginaFinal" => "550"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23345621"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            5 => array:3 [
              "identificador" => "bib0170"
              "etiqueta" => "6"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Influence of high convection volumes in removal performances of on-line haemodiafiltration &#40;HDF&#41;"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "N&#46; Gayrard"
                            1 => "A&#46; Ficheux"
                            2 => "F&#46; Duranton"
                            3 => "C&#46; Guzman"
                            4 => "I&#46; Szwarc"
                            5 => "J&#46; Bismuth-Mondolfo"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Nephrol Dial Transplant"
                        "fecha" => "2013"
                        "volumen" => "28"
                        "numero" => "Suppl&#46; 1"
                        "paginaInicial" => "i30"
                        "paginaFinal" => "i32"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            6 => array:3 [
              "identificador" => "bib0175"
              "etiqueta" => "7"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Is it useful to increase dialysate flow rate to improve the delivered Kt&#63;"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "M&#46; Albalate"
                            1 => "R&#46; P&#233;rez-Garc&#237;a"
                            2 => "P&#46; de Sequera"
                            3 => "E&#46; Corchete"
                            4 => "R&#46; Alcazar"
                            5 => "M&#46; Ortega"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1186/s12882-015-0013-9"
                      "Revista" => array:5 [
                        "tituloSerie" => "BMC Nephrol&#46;"
                        "fecha" => "2015"
                        "volumen" => "16"
                        "paginaInicial" => "20"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25884763"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            7 => array:3 [
              "identificador" => "bib0180"
              "etiqueta" => "8"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "&#191;Cu&#225;l es el flujo de ba&#241;o &#243;ptimo en la hemodiafiltraci&#243;n on-line posdilucional&#63;"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "M&#46; Albalate"
                            1 => "P&#46; de Sequera"
                            2 => "R&#46; P&#233;rez-Garc&#237;a"
                            3 => "E&#46; Corchete"
                            4 => "R&#46; Alc&#225;zar"
                            5 => "M&#46; Ortega"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.nefro.2015.04.007"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nefrolog&#237;a&#46;"
                        "fecha" => "2015"
                        "volumen" => "35"
                        "paginaInicial" => "533"
                        "paginaFinal" => "538"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26565938"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            8 => array:3 [
              "identificador" => "bib0185"
              "etiqueta" => "9"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Optimization of dialysate flow in on-line hemodiafiltration"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "F&#46; Maduell"
                            1 => "R&#46; Ojeda"
                            2 => "M&#46; Arias-Guill&#233;n"
                            3 => "N&#46; Fontser&#233;"
                            4 => "M&#46; Vera"
                            5 => "E&#46; Mass&#243;"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.nefro.2015.06.019"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nefrolog&#237;a&#46;"
                        "fecha" => "2015"
                        "volumen" => "35"
                        "paginaInicial" => "473"
                        "paginaFinal" => "478"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26306957"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            9 => array:3 [
              "identificador" => "bib0190"
              "etiqueta" => "10"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Poly&#40;N-vinyl-2-pyrrolidone&#41; elution from polysulfone dialysis membranes by varying solvent and wall shear stress"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:5 [
                            0 => "K&#46; Namekawa"
                            1 => "M&#46; Matsuda"
                            2 => "M&#46; Fukuda"
                            3 => "A&#46; Kaneko"
                            4 => "K&#46; Sakai"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1007/s10047-012-0629-5"
                      "Revista" => array:6 [
                        "tituloSerie" => "J Artif Organs&#46;"
                        "fecha" => "2012"
                        "volumen" => "15"
                        "paginaInicial" => "185"
                        "paginaFinal" => "192"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22311608"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            10 => array:3 [
              "identificador" => "bib0195"
              "etiqueta" => "11"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Eluted substances from hemodialysis membranes elicit positive skin prick tests in bioincompatible patients"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:5 [
                            0 => "S&#46; Konishi"
                            1 => "A&#46; Fukunaga"
                            2 => "H&#46; Yamashita"
                            3 => "M&#46; Miyata"
                            4 => "M&#46; Usami"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1111/aor.12392"
                      "Revista" => array:6 [
                        "tituloSerie" => "Artif Organs&#46;"
                        "fecha" => "2015"
                        "volumen" => "39"
                        "paginaInicial" => "343"
                        "paginaFinal" => "351"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25327279"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            11 => array:3 [
              "identificador" => "bib0200"
              "etiqueta" => "12"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Hypersensitivity reactions to synthetic haemodialysis membranes &#8212; an emerging issue&#63;"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:2 [
                            0 => "M&#46;A&#46; Alvarez-de Lara"
                            1 => "A&#46; Mart&#237;n-Malo"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.3265/Nefrologia.pre2014.Jul.12682"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nefrolog&#237;a&#46;"
                        "fecha" => "2014"
                        "volumen" => "34"
                        "paginaInicial" => "698"
                        "paginaFinal" => "702"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25415569"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            12 => array:3 [
              "identificador" => "bib0205"
              "etiqueta" => "13"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Hypersensitivity reactions to synthetic haemodialysis membranes"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "R&#46;J&#46; S&#225;nchez-Villanueva"
                            1 => "E&#46; Gonz&#225;lez"
                            2 => "S&#46; Quirce"
                            3 => "R&#46; D&#237;az"
                            4 => "L&#46; Alvarez"
                            5 => "D&#46; Men&#233;ndez"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.3265/Nefrologia.pre2014.May.12552"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nefrolog&#237;a&#46;"
                        "fecha" => "2014"
                        "volumen" => "34"
                        "paginaInicial" => "520"
                        "paginaFinal" => "525"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25036066"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            13 => array:3 [
              "identificador" => "bib0210"
              "etiqueta" => "14"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Efecto del triacetato de celulosa asim&#233;trico &#40;Solacea<span class="elsevierStyleSup">&#174;</span>&#41; en hemodiafiltraci&#243;n on line &#40;HDF Ol&#41;&#44; sobre monocitos inflamatorios"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "M&#46; Albalate"
                            1 => "P&#46; Martinez Miguel"
                            2 => "I&#46; Bohorquez"
                            3 => "P&#46; de Sequera"
                            4 => "H&#46; Bouarich"
                            5 => "R&#46; Ramirez"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Nefrolog&#237;a&#46;"
                        "fecha" => "2016"
                        "volumen" => "36"
                        "numero" => "Supl&#46; 1"
                        "paginaInicial" => "70"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            14 => array:3 [
              "identificador" => "bib0215"
              "etiqueta" => "15"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "The choice of hemodialysis membrane affects bisphenol A levels in blood"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "E&#46; Bosch-Panadero"
                            1 => "S&#46; Mas"
                            2 => "D&#46; Sanchez-Ospina"
                            3 => "V&#46; Camarero"
                            4 => "M&#46;V&#46; P&#233;rez-G&#243;mez"
                            5 => "I&#46; Saez-Calero"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1681/ASN.2015030312"
                      "Revista" => array:6 [
                        "tituloSerie" => "J Am Soc Nephrol&#46;"
                        "fecha" => "2016"
                        "volumen" => "27"
                        "paginaInicial" => "1566"
                        "paginaFinal" => "1574"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26432902"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            15 => array:3 [
              "identificador" => "bib0220"
              "etiqueta" => "16"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Bisphenol A in hemodialysis patient&#58; An open question"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:1 [
                            0 => "M&#46; Neri"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1159/000446227"
                      "Revista" => array:6 [
                        "tituloSerie" => "Blood Purif&#46;"
                        "fecha" => "2016"
                        "volumen" => "42"
                        "paginaInicial" => "75"
                        "paginaFinal" => "76"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/27189594"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            16 => array:3 [
              "identificador" => "bib0225"
              "etiqueta" => "17"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Therapeutic efficacy and cost effectiveness of high cut-off dialyzers compared to conventional dialysis in patients with cast nephropathy"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:5 [
                            0 => "A&#46; Curti"
                            1 => "A&#46; Schwarz"
                            2 => "J&#46; Trachsler"
                            3 => "Y&#46; Tomonaga"
                            4 => "P&#46;M&#46; Amb&#252;hl"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1371/journal.pone.0159942"
                      "Revista" => array:6 [
                        "tituloSerie" => "PLoS One&#46;"
                        "fecha" => "2016"
                        "volumen" => "11"
                        "paginaInicial" => "e0159942"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/27467401"
                            "web" => "Medline"
                          ]
                        ]
                        "itemHostRev" => array:3 [
                          "pii" => "S0140673612608150"
                          "estado" => "S300"
                          "issn" => "01406736"
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            17 => array:3 [
              "identificador" => "bib0230"
              "etiqueta" => "18"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Tratamiento con hemodi&#225;lisis del fracaso renal agudo en el mieloma m&#250;ltiple con filtros de alto poro &#40;high cut-off&#41;"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "G&#46; Mart&#237;n-Reyes"
                            1 => "R&#46; Toledo-Rojas"
                            2 => "A&#46; Torres-de Rueda"
                            3 => "E&#46; Sola-Moyano"
                            4 => "L&#46; Blanca-Martos"
                            5 => "L&#46; Fuentes-S&#225;nchez"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.3265/Nefrologia.pre2011.Nov.11094"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nefrolog&#237;a&#46;"
                        "fecha" => "2012"
                        "volumen" => "32"
                        "paginaInicial" => "35"
                        "paginaFinal" => "43"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22294003"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            18 => array:3 [
              "identificador" => "bib0235"
              "etiqueta" => "19"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Performance of hemodialysis with novel medium cut-off dialyzers"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "A&#46;H&#46; Kirsch"
                            1 => "R&#46; Lyko"
                            2 => "L&#46;G&#46; Nilsson"
                            3 => "W&#46; Beck"
                            4 => "M&#46; Amdahl"
                            5 => "P&#46; Lechner"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1093/ndt/gfw310"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nephrol Dial Transplant&#46;"
                        "fecha" => "2017"
                        "volumen" => "32"
                        "paginaInicial" => "165"
                        "paginaFinal" => "172"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/27587605"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            19 => array:3 [
              "identificador" => "bib0240"
              "etiqueta" => "20"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Convection-enhanced high-flux hemodialysis"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "L&#46; Kyungsoo"
                            1 => "K&#46; Lee"
                            2 => "J&#46;H&#46; Jeong"
                            3 => "C&#46;H&#46; Mun"
                            4 => "S&#46;R&#46; Lee"
                            5 => "K&#46;J&#46; Yoo"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1111/j.1525-1594.2007.00436.x"
                      "Revista" => array:6 [
                        "tituloSerie" => "Artif Organs&#46;"
                        "fecha" => "2007"
                        "volumen" => "31"
                        "paginaInicial" => "653"
                        "paginaFinal" => "658"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/17651122"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            20 => array:3 [
              "identificador" => "bib0245"
              "etiqueta" => "21"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Principles and practice of internal hemodiafiltration"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:2 [
                            0 => "G&#46;B&#46; Fiore"
                            1 => "C&#46; Ronco"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1159/000107248"
                      "Revista" => array:6 [
                        "tituloSerie" => "Contrib Nephrol&#46;"
                        "fecha" => "2007"
                        "volumen" => "158"
                        "paginaInicial" => "177"
                        "paginaFinal" => "184"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/17684356"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            21 => array:3 [
              "identificador" => "bib0250"
              "etiqueta" => "22"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Effect of high fiber density ratio polysulfone dialyzer on protein removal"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "T&#46; Tomo"
                            1 => "M&#46; Matsuyama"
                            2 => "T&#46; Nakata"
                            3 => "J&#46; Kadota"
                            4 => "S&#46; Toma"
                            5 => "N&#46; Koga"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1159/000133430"
                      "Revista" => array:6 [
                        "tituloSerie" => "Blood Purif&#46;"
                        "fecha" => "2008"
                        "volumen" => "26"
                        "paginaInicial" => "347"
                        "paginaFinal" => "353"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/18487878"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            22 => array:3 [
              "identificador" => "bib0255"
              "etiqueta" => "23"
              "referencia" => array:1 [
                0 => array:1 [
                  "referenciaCompleta" => "Maduell F&#44; Ojeda R&#44; Belmar L&#44; Mungu&#237;a P&#44; Sango C&#44; Mart&#237;nez-D&#237;az AI&#44; et al&#46; Valoraci&#243;n del di&#225;metro interno del dializador en hemodiafiltraci&#243;n on-line&#46; Nefrolog&#237;a&#46;"
                ]
              ]
            ]
            23 => array:3 [
              "identificador" => "bib0260"
              "etiqueta" => "24"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Sistema Ultracontrol<span class="elsevierStyleSup">&#174;</span> en la cl&#237;nica diaria de la hemodiafiltraci&#243;n en l&#237;nea posdilucional&#58; volumen de infusi&#243;n alcanzado y aplicabilidad con distintos dializadores"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "M&#46; Albalate Ram&#243;n"
                            1 => "R&#46; P&#233;rez Garc&#237;a"
                            2 => "P&#46; de Sequera Ortiz"
                            3 => "R&#46; Alc&#225;zar Arroyo"
                            4 => "E&#46; Corchete Prats"
                            5 => "M&#46; Puerta Carretero"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.3265/Nefrologia.pre2011.Sep.11122"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nefrolog&#237;a&#46;"
                        "fecha" => "2011"
                        "volumen" => "31"
                        "paginaInicial" => "683"
                        "paginaFinal" => "689"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22130284"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            24 => array:3 [
              "identificador" => "bib0265"
              "etiqueta" => "25"
              "referencia" => array:1 [
                0 => array:3 [
                  "comentario" => "Sa400"
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "D&#233;puration de la Beta2-microglobuline et pertes d&#225;lbumine en HDF post-dilution&#58; effect membrane"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:6 [
                            0 => "F&#46; Le Roy"
                            1 => "M&#46; Hanoy"
                            2 => "D&#46; Bertrand"
                            3 => "C&#46; Freguin"
                            4 => "S&#46; Grange"
                            5 => "M&#46; Godin"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:2 [
                        "tituloSerie" => "EDTA"
                        "fecha" => "2009"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            25 => array:3 [
              "identificador" => "bib0270"
              "etiqueta" => "26"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Are all dialyzers compatible with the convective volumes suggested for postdilution online hemodiafiltration&#63;"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "J&#46; Potier"
                            1 => "G&#46; Queffeulou"
                            2 => "J&#46; Bouet"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.5301/ijao.5000525"
                      "Revista" => array:6 [
                        "tituloSerie" => "Int J Artif Organs&#46;"
                        "fecha" => "2016"
                        "volumen" => "39"
                        "paginaInicial" => "460"
                        "paginaFinal" => "470"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/27791259"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            26 => array:3 [
              "identificador" => "bib0275"
              "etiqueta" => "27"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "A new Poly&#40;methyl methacrylate&#41; membrane Sialyzer NF&#44; with adsorptive and antithrombotic properties"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "W&#46; Oshihara"
                            1 => "H&#46; Fujieda"
                            2 => "Y&#46; Ueno"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1159/000450806"
                      "Revista" => array:6 [
                        "tituloSerie" => "Contrib Nephrol&#46;"
                        "fecha" => "2017"
                        "volumen" => "189"
                        "paginaInicial" => "230"
                        "paginaFinal" => "236"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/27951573"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            27 => array:3 [
              "identificador" => "bib0280"
              "etiqueta" => "28"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "A noninferiority trial comparing a heparin-grafted membrane plus citrate-containing dialysate versus regional citrate anticoagulation&#58; Results of the CiTED study"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:6 [
                            0 => "B&#46; Meijers"
                            1 => "C&#46; Metalidis"
                            2 => "T&#46; Vanhove"
                            3 => "R&#46; Poesen"
                            4 => "D&#46; Kuypers"
                            5 => "P&#46; Evenepoel"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1093/ndt/gfw461"
                      "Revista" => array:6 [
                        "tituloSerie" => "Nephrol Dial Transplant&#46;"
                        "fecha" => "2017"
                        "volumen" => "32"
                        "paginaInicial" => "707"
                        "paginaFinal" => "714"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/28407129"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
          ]
        ]
      ]
    ]
  ]
  "idiomaDefecto" => "es"
  "url" => "/02116995/0000003800000001/v1_201801090621/S0211699517301777/v1_201801090621/es/main.assets"
  "Apartado" => array:4 [
    "identificador" => "48184"
    "tipo" => "SECCION"
    "en" => array:2 [
      "titulo" => "Editoriales"
      "idiomaDefecto" => true
    ]
    "idiomaDefecto" => "en"
  ]
  "PDF" => "https://static.elsevier.es/multimedia/02116995/0000003800000001/v1_201801090621/S0211699517301777/v1_201801090621/es/main.pdf?idApp=UINPBA000064&text.app=https://revistanefrologia.com/"
  "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0211699517301777?idApp=UINPBA000064"
]
Información del artículo
ISSN: 02116995
Idioma original: Español
Datos actualizados diariamente
año/Mes Html Pdf Total
2024 Noviembre 64 9 73
2024 Octubre 561 52 613
2024 Septiembre 571 46 617
2024 Agosto 518 59 577
2024 Julio 353 54 407
2024 Junio 367 61 428
2024 Mayo 311 54 365
2024 Abril 353 60 413
2024 Marzo 306 37 343
2024 Febrero 285 50 335
2024 Enero 567 36 603
2023 Diciembre 254 28 282
2023 Noviembre 421 53 474
2023 Octubre 403 37 440
2023 Septiembre 400 41 441
2023 Agosto 368 37 405
2023 Julio 283 38 321
2023 Junio 306 31 337
2023 Mayo 363 49 412
2023 Abril 324 36 360
2023 Marzo 292 26 318
2023 Febrero 265 44 309
2023 Enero 185 41 226
2022 Diciembre 201 55 256
2022 Noviembre 316 47 363
2022 Octubre 344 63 407
2022 Septiembre 398 66 464
2022 Agosto 313 58 371
2022 Julio 202 68 270
2022 Junio 199 70 269
2022 Mayo 195 50 245
2022 Abril 172 81 253
2022 Marzo 203 72 275
2022 Febrero 209 54 263
2022 Enero 209 52 261
2021 Diciembre 207 65 272
2021 Noviembre 258 67 325
2021 Octubre 318 80 398
2021 Septiembre 276 61 337
2021 Agosto 268 58 326
2021 Julio 193 45 238
2021 Junio 207 51 258
2021 Mayo 233 69 302
2021 Abril 564 88 652
2021 Marzo 268 87 355
2021 Febrero 170 50 220
2021 Enero 158 51 209
2020 Diciembre 278 52 330
2020 Noviembre 324 69 393
2020 Octubre 238 60 298
2020 Septiembre 269 54 323
2020 Agosto 251 49 300
2020 Julio 349 62 411
2020 Junio 333 85 418
2020 Mayo 399 73 472
2020 Abril 407 52 459
2020 Marzo 521 56 577
2020 Febrero 516 63 579
2020 Enero 457 100 557
2019 Diciembre 363 41 404
2019 Noviembre 712 116 828
2019 Octubre 838 115 953
2019 Septiembre 884 136 1020
2019 Agosto 825 94 919
2019 Julio 629 80 709
2019 Junio 587 92 679
2019 Mayo 615 116 731
2019 Abril 440 90 530
2019 Marzo 317 99 416
2019 Febrero 194 47 241
2019 Enero 257 53 310
2018 Diciembre 289 65 354
2018 Noviembre 611 29 640
2018 Octubre 518 13 531
2018 Septiembre 265 18 283
2018 Agosto 208 18 226
2018 Julio 208 21 229
2018 Junio 203 15 218
2018 Mayo 241 11 252
2018 Abril 257 24 281
2018 Marzo 238 21 259
2018 Febrero 352 19 371
2018 Enero 648 23 671
2017 Diciembre 178 8 186
2017 Noviembre 93 12 105
Mostrar todo

Siga este enlace para acceder al texto completo del artículo

Idiomas
Nefrología
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?