TY - JOUR T1 - Optimisation of dialysate flow in on-line hemodiafiltration JO - Nefrología (English Edition) T2 - AU - Maduell,Francisco AU - Ojeda,Raquel AU - Arias-Guillén,Marta AU - Fontseré,Néstor AU - Vera,Manel AU - Massó,Elisabeth AU - Gómez,Miquel AU - Rodas,Lida AU - Bazán,Giannina AU - Jiménez-Hernández,Mario AU - Piñeiro,Gastón AU - Rico,Nayra SN - 20132514 M3 - 10.1016/j.nefroe.2015.11.002 DO - 10.1016/j.nefroe.2015.11.002 UR - https://revistanefrologia.com/en-optimisation-dialysate-flow-in-on-line-articulo-S2013251415000942 AB - IntroductionCurrently, on-line hemodiafiltration (OL-HDF) is the most effective technique. Several randomised studies and meta-analyses have shown a reduced mortality and a direct association with convective volume has been reported. At present, it has not been established if an increased dialysate flow (Qd) shows in improved results in terms of convective and depurative efficiency. We aim at assessing the effects of Qd variations on convective volume and its depurative capacity in patients on OL-HDF. Material and methodsA total of 59 patients (45 men and 14 women) from a OL-HDF programme in which a monitor 5008 Cordiax with auto-substitution was used, were enrolled. Patients were assessed in 5 sessions with post-dilutional OL-HDF, using helixone-based dialyzers, with only Qd being changed (300, 400, 500, 600 and 700mL/min). Serum levels of urea (60Da), creatinine (113Da), β2-microglobulin (11,800Da), myoglobin (17,200Da) and α1-microglobulin (33,000Da) were measured at the beginning and at the end of each session, in order to estimate the percent reduction of such solutes. ResultsAn increased dialysate volume per session was observed, from 117.9±6.4L with Qd 300mL/min to 232.4±12L with Qd 700mL/min. No changes were found in replacement volume or convective volume. Regarding diffusion, Qd increase was associated to a significantly increased dialysis dose, with an increased Kt from 68±6.9L with Qd 300mL/min to 75.5±7.3L with Qd 700mL/min (P<0.001), and a gradually increased percent reduction in urea associated to increased Qd with significantly lower levels being found with Qd 300mL/min. No changes were found in other measured substances. ConclusionQd variations in OL-HDF do not change convective volume. A higher Qd was associated to a slightly increased urea clearance with no change being observed for medium and large molecules. Qd optimisation to the minimal level assuring an adequate dialysis dose and allowing water and dialysate use to be rationalised should be recommended. ER -